Floor fixing dimensions

of the outdoor unit

(Unit:mm)

Floor fixing dimensions

of the outdoor unit

(Unit:mm)

Floor fixing dimensions

of the outdoor unit

(Unit:mm)

113.5

583

113.5

5.

91

3

140

500

140

65

2

140

415

140

08

2

HSU-09C13

HSU-12C13

HSU-09C03/Z1

HSU-12C03/Z1

HSU-09C12

HSU-12C12

HSU-18C13

HSU-18CK03

HSU-24C13

HSU-22C13

Fix the unit to concrete or block with bolts(   10mm) and nuts firmly and horizontally.

Fixing of outdoor unit

Indoor Unit

Selection of Installation Place

Power Source

Selection of pipe

Outdoor Unit

When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nails
or wires in consideration of earthquake and strong wind.
If vibration may affect the house, fix the unit by attaching a vibration-proof mat.

Place, robust not causing vibration, where the body can be supported

sufficiently.

Place, not affected by heat or steam generated in the vicinity, where

inlet and outlet of the unit are not disturbed.

Place, possible to drain easily, where piping can be connected with the

outdoor unit.

Place, where cold air can be spread in a room entirely.

Place, nearby a power receptacle, with enough space around. (Refer

to drawings).

Place where the distance of more than lm from televisions, radios,

wireless apparatuses and fluorescent lamps can be left.

In the case of fixing the remote controller on a wall, place where the

indoor unit can receive signals when the fluorescent lamps in the room

are lightened.

Place, which is less affected by rain or direct sunlight and is

sufficiently ventilated.

Place, possible to bear the unit, where vibration and noise are

not increased.

Place, where discharged wind and noise do not cause a

nuisance to the neighbors.

Place, where a distance marked       is available as illustrated

in the above figure.

Before inserting power plug into receptacle, check the voltage without fail. The power source is the same as the corresponding name plate.
Install an exclusive branch circuit of the power.
A receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable by cutting it.

To this unit, both liquid and gas pipes shall be insulated
as they become Iow temperature in operation.
Use optional parts for piping set or pipes covered with
equivalent insulation material.

Gas pipe(     )

For 09

6.35mm(1/4")

Gas pipe(     )

9.52mm(3/8")

For 12,18

6.35mm(1/4")

12.7mm(1/2")

For 22 24

9.52mm(3/8")

15.88mm(5/8")

2

Summary of Contents for HSU-09C12 - annexe 1

Page 1: ...ose Heating insulating material Piping hole cover Arrangement of piping directions Rear left Rear right Left Below Right The marks from to in the figure are the parts numbers The distance between the...

Page 2: ...Place nearby a power receptacle with enough space around Refer to drawings Place where the distance of more than lm from televisions radios wireless apparatuses and fluorescent lamps can be left In th...

Page 3: ...ticle When the mounting plate is first fixed for the position of wall hole Fix to side bar and lintel a mounting bar Which is separately sold and then fasten the plate to the fixed mounting bar Make a...

Page 4: ...aslant from the underside and then put it down perpendicularly Remove terminal cover at right bottom corner of indoor unit then take off wiring cover by removing its screws When connecting the cable a...

Page 5: ...ables have been properly inserted and tightened After the cable connection never fail to fasten the connected cable with the wiring cover Note When connecting the cable confirm the terminal number of...

Page 6: ...ng easier The max vertical distance between the indoor unit and the outdoor unit is 5 m Use the same method on indoor unit Loosen the screws on terminal block and insert the plugs fully into terminal...

Page 7: ...caps on the valves with specified torque Valve rod Valve cap 7 9 20 25 Tighten torque N m During this procedure 50g or 80g only for 22k and 24k unit refrigerant will be discharged in piping This must...

Page 8: ...nfirm that drainage is carried out surely to outdoor In case that the attached drain hose is in a room please apply heat insulation to it without fail Please kindly explain to our customers how to ope...

Page 9: ...ber as Izquierda Trasera izquierda Trasera derecha Derecha Debajo m s de 10 cm m s de 5 cm m s de 10 cm Debe prestarse atenci n a que la manguera de drenaje no quede elevada m s de 10 cm m s de 10 cm...

Page 10: ...y no aumentar las vibraciones ni el ruido La zona deber ser una en la que el ruido y el viento emitido no provoquen perturbaciones a los vecinos La zona ser una en la que una distancia marcada est dis...

Page 11: ...a de montaje por vez primera para la situaci n del orificio en la pared 2 Perforaci n de la pared y ajuste de la tapa del orificio de la tuber a Hacer un orificio de 60 mm de di metro descendiendo lev...

Page 12: ...ar el conectado al aislamiento t rmic de la pieza de conexi n Ajuste de la carcasa de la unidad interior Colgar con seguridad la unidad en las muescas de la placa de montaje Mover la unidad de lado a...

Page 13: ...tituido por el fabricante o su agente de mantenimiento o una persona con cualificaci n similar El tipo de cable de conexi n es H05 07RN F o 245IEC57 YZW 2 Si el fusible de la placa PC est roto cambiar...

Page 14: ...illos Introducir el cable de acuerdo al n mero del terminal de la misma forma que la unidad interior Si el cableado no es correcto no podr haber un funcionamiento correcto y puede estropearse el contr...

Page 15: ...i n especificada 5 Ajustar las tapas en las v lvulas con la fuerza de torsi n especificada Torsi n de ajuste N m V stago de v lvula 7 9 Tapa de v lvula 20 25 Cuando el tubo de conexi n excede los 5 me...

Page 16: ...sma aislamiento t rmico total Verificaci ndeinstalaci nypuestaapunto Explicar amablemente a nuestros clientes el modo de utilizaci n del aparato empleando el manual de instrucciones Verificarelementos...

Reviews: