background image

Parts and Functions

Used to set healthy operation.

9. HEALTH button

14

POWER/SOFT

Used to select CODE A or B with a press,A or B
will be displayed on LCD.
Please select A without special explanation.

1.CODE

 When the remote controller appears abnormal,
 use a sharp pointed article   to press this button
 to reset the  remote controller normal.

2.RESET

Used to select TIMER ON, TIMER OFF,
TIMER ON-OFF.

4. TIMER button

 Used to set correct time.

5. CLOCK button

Used to select sleep mode.

6. SLEEP button

7. MODE button

AUTO

COOL

DRY

FAN

HEAT

Used to set clock and timer setting.

8. HOUR button

3

30

Used for unit start and stop.

10. ON/OFF button

11. TIMER ON display

12. FAN SPEED display

13. LOCK display
14. SWING UP/DOWN display
15. SLEEP display
16. HEALTH display

Used to select your desired temperature.

18. Operation mode display

20. POWER/SOFT display

21. Left/right air flow display

 Remote controller: to display the TEMP. setting.

22. TEMP display

23. TIMER OFF display

24. CLOCK display
25. TEMP button

Used to select fan speed: LOW,MED, HI, AUTO.

26. FAN button

Used to set the health airflow mode.

27. HEALTH AIRFLOW button

28. SWING UP/DOWN button

Used to select up or down air sending direction.

29. SWING LEFT/RIGHT button

Used to select left/right air flow.

30. FRESH button

Used to confirm timer and clock settings.

31. SET button

32. POWER/SOFT button

Use to set fresh air function.

Used to lock buttons and LCD display. If pressed, the
other buttons will be disabled and the lock condition
display appears. Press it once again, lock will be
canceled and lock condition display disappears.

33. LOCK

17

FRESH

28

19

NOTE:(1) The following functions and related displays are not available:

(2) Cooling only unit do not have functions and displays related with heating.

33

3.LIGHT button

Control the lightening and extinguishing of
the indoor  LCD display board.

and

17.FRESH AIR  display

19.Singal sending  display

Operation mode

AUTO

HEAT FAN

COOL

DRY

Remote controller

LOW

HI

MED

AUTO

Summary of Contents for HSM09HS03/R2(DB)

Page 1: ...SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL Please read this operation manual before using the air conditioner HSM09HS03 R2 DB HSM09HS03 R2 DB 2HUM18H03 R2 DB HSM09HS03 R2 DB HSM12HS03 R2 DB 2HUM...

Page 2: ...disposal services nearest to your house Disposal of the packaging of your new air conditioner Before starting the air conditioner read the information given in the User s Guide caref ully The User s G...

Page 3: ...imum D B W B Minimum D B W B Outdoor Indoor Outdoor Heating Specifications The machine is adaptive in following situation 10 The power plug and connecting cable must have acquired the local attestatio...

Page 4: ...Please call Sales Service Shop for the Installation Do not attempt to install the air conditioner by yourself because improper works may cause electric shock fire water leakage lnstallation in a inad...

Page 5: ...Please call Sales Service Shop for the Installation Do not attempt to install the air conditioner by yourself because improper works may cause electric shock fire water leakage lnstallation in a inad...

Page 6: ...different operation models OPERATE RED RED GREEN GREEN GREEN YELLOW COOL DRY HEAT TIMER HEALTH Display board Inlet Anion generator Vertical flap Use remote controller to adjust up and down air flow Do...

Page 7: ...controller to display the TEMP setting 22 TEMP display 23 TIMER OFF display 24 CLOCK display 25 TEMP button Used to select fan speed LOW MED HI AUTO 26 FAN button Used to set the health airflow mode...

Page 8: ...as well Don t throw or knock the remoter controller When electronic started type fluorescent lamp or change over type fluorescent lamp or wireless telephone is installed in the room the receiver is a...

Page 9: ...the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room When the fan in the indoor unit does not work...

Page 10: ...troller Then Select Auto operation AUTO COOL DRY FAN HEAT Press FAN button For each press fan speed changes as follows Remote controller Press TEMP button Every time the button is pressed temp setting...

Page 11: ...it will increase rapidly Every time the button is pressed temp setting decrease 1o C if kept depressed it will decrease rapidly Select a desired temperature 4 Fan speed selection 3 Select temp settin...

Page 12: ...a desired temperature 4 Fan speed selection 3 Select temp setting 5 Unit stop Press ON OFF button the unit stops COOL operation starts when room temp is higher than temp setting On reaching temp setti...

Page 13: ...Fan speed selection 4 Unit stop About FAN operation In FAN operation mode the unit will not operate in COOL or HEAT mode but only in FAN mode AUTO is not available in FAN mode And temp setting is disa...

Page 14: ...ase 1o C if kept depressed it will decrease rapidly Select a desired temperature 4 Fan speed selection 3 Select temp setting 5 Unit stop Press ON OFF button the unit stops AUTO LOW MED HI AUTO COOL DR...

Page 15: ...The vertical flap will swing according to the above positions HEAT AUTO 1 Status display of air sending Horizontal louvers Pos 1 Pos 2 Pos 3 Pos 4 Pos 5 Pos 6 Pos 7 Pos 8 3 Left and right air flow dir...

Page 16: ...tting so that room temperature won t be too Iow for your sleep Remote Controller SLEEP operation starts SLEEP operation stops SLEEP operation starts SLEEP operation stops Approx 6hrs 1 hr 1 hr 1 hr 3...

Page 17: ...utton is pressed display changes as follows Remote controller BLANK TIMER ON TIMER OFF TIMER ON OFF Then select your desired TIMER mode TIMER ON or TIMER OFF or will flash 3 Time setting Press HOUR bu...

Page 18: ...OFF will flash 3 Time setting Press HOUR button Every time the button is pressed time setting increases 1 min if kept depressed it will increase rapidly Every time the button is pressed time setting d...

Page 19: ...FT button twice POWER SOFT disappears In SOFT operation mode fan speed automatically takes LOW changes as follows Stop the display at SOFT BLANK POWER Press POWER SOFT button Every time the button is...

Page 20: ...tting the health airflow function the position of inlet and outlet grills is fixed 2 In heating it is better to select the mode 3 In cooling it is better to select the mode 4 In cooling and dry using...

Page 21: ...in the test operation when the room temperature is below 16 O C do not use it in the normal operation Continue to press the test operation switch for more than 5 seconds After you hear the Pi sound t...

Page 22: ...tion If the unit is not to be used for a long time turn off the power supply main switch Use the timer effectively Use the louvers effectively Do not block the air inlet or outlet Maintenance Proper t...

Page 23: ...etely fixed behind the stopper If the right and left filters are not attached correctly that may cause defects Remote Controller Do not use the following for cleaning Do not use water wipe the control...

Page 24: ...er NOTE The air purifying filter of the bacteria killing medium and the electrostatic air purifying filter accessories with machine will be used based on real situation The green aspect of the bacteri...

Page 25: ...for 2 3 hours Put off the power supply cord Take out the batteries from the wireless remote controller Cleaning the body To prevent breeding mold or bad smell be sure to operate at the designated tem...

Page 26: ...e plug insert the plug of the power supply cord into the outlet completely In case of suing exclusive circuit breaker switch on the circuit breaker NO WET HAND EARTHING Operation without filter may ca...

Reviews: