Haier HSM07RU103/R2(DB) Operation Manual Download Page 3

3

Operation

AUTO

COOL

DRY

FAN

HEAT

2.Select operation mode

Press FAN button. For each press, fan speed changes

follows:

Press MODE button. For each press, operation mode
changes as follows:

Remote controller:

Remote controller:

Press

button

Every time the button is pressed, temp.setting
increase 1

o

C,if kept depressed, it will increase

rapidly

Every time the button is pressed, temp.setting

decrease 1

o

C,if kept depressed, it will decrease

rapidly

Select a desired temperature.

4.Fan speed selection

3.Select temp.setting

Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner
automatically adjusts the fan speed according to room
temperature.

LOW

MED

HI

AUTO

1. Unit start

 Press ON/OFF on the remote controller, unit starts.

TEMP+

TEMP-

TEMP+

TEMP-

Base  Operation

Remote controller

   Air Flow Direction Adjustment

Vertical flap

Pos.1

Pos.2

Pos.3

Pos.4

Pos.5

Pos.6

(Auto swing)

1.Status display of air flow

When restart after remote turning off, the remote 

         memorize the previous 

2.Left and right air flow adjustment

Cautions:

When adjusting the flap by hand,turn off the unit.

When humidity is high,condensate water might occur 

adjusted to left or 

It is advisable not to keep horizontal flap at downward
position for a long time in COOLor DRY

otherwise, condensate water might occur.

Emergency Operation:

temperature is below 16

o

C, do not use it in the 

Test operation:

Use this switch in the test operation when the room

normal operation.

 your finger from the switch: the cooling

Continue to press the test operation 

switch for more than 5 seconds . After

 you hear the "Pi" sound twice,

release

Test ope ration switch is the same as emergency switch.

operation starts with the air flow speed "Hi".

Emergency operation and test operation

 Use this operation only when the remote controller
 is defective or lost.

When the emergency operation switch is
pressed,the" Pi "sound is heard once, which 

the start of this operation.

In this operation, the system automatically selects

the operation modes,cooling or fan or heat,
according to the room temperature.

.

It is not possible to operate in dry mode.

Room

temperature

Operation

   mode

Designated

temperature

Timer

mode

Air flow

ABOVE 23

O

C

BELOW 23

O

C

COOLING

HEAT

23

O

C

26

O

C

NO

NO

AUTOMATIC

AUTOMATIC

(C

ooling only uint

˅

Room  temperature

Operation

   mode

Designated

temperature

Timer

mode

Air flow

BELOW 23

O

C

FAN

26

O

C

NO

AUTOMATIC

at air outlet if all vertical louvers are 

right.

mode ,

controller will automatically

Note:

set swing position.

means

as

TEMP

TEMP

+

-

FAN

MODE

HEALTH

AIRFLOW

FRESH

CLOCK

TIME +

TIMER

TIME -

POWER

/SOFT

SET

SLEEP

HEALTH

RESET

CODE

LIGHT

LOCK

SWING

SWING

Operation

Mode

AUTO

Remote

Controller

Note

COOL

DRY

HEAT

FAN

In DRY mode , when room temperature becomes
lower than temp.2

o

C, unit will run 

intermittently at LOW speed regardless of FAN 

Under the mode of auto operation, air conditioner 

will automatically select Cool or Heat operation

according to room temperature

to AUTO the air conditioner automatically adjusts

temperature.

When FAN is set 

the fan speed according to room

In FAN operation mode , the unit will not operate in

COOL or HEAT mode  but only in  FAN mode ,
AUTO is not available in FAN mode. And temp.
setting is disabled. In FAN mode, sleep operation 

 setting.

is not available. 

In HEAT mode, warm air will blow out after a short 
period of the time due to cold-draft prevention function.
When FAN is set to AUTO, the air conditioner automatically 
adjusts the fan speed according to room temperature.

Pi

Pi Pi

(manual)

Pos.1

Pos.2

Pos.3

Pos.4

Pos.5

Pos.6

Pos.7

Pos.8

For each press of

button, remote controller 

displays as follows :

remote controller:

Summary of Contents for HSM07RU103/R2(DB)

Page 1: ...M AIR CONDITIONER OPERATION MANUAL Keep this operation manual for future reference Contents 2 3 6 8 7 CAUTIONS PARTS AND FUNCTIONS OPERATION MAINTENANCE TROUBLE SHOOTING HSU 09RUG03 R2 SDB HSU 12RUG03...

Page 2: ...y board LCD special Please select A without will When the remote controller 31 RESET button button The distance between the signal transmission head and the rece iver hole should be within 7m without...

Page 3: ...rgency operation and test operation Use this operation only when the remote controller is defective or lost When the emergency operation switch is pressed the Pi sound is heard once which the start of...

Page 4: ...will become 2 lower than temp setting After another 1 hours temp decrease by 2 rises by 1 futher The unit will run for further 3 hours then stops Temp is lower than temp setting so that room temperat...

Page 5: ...pplied with the product The filled out label must be adhered in the proximity of the product charging port e g onto the inside of the stop value cover A contains fluorinated greenhouse gases covered b...

Page 6: ...ated in the right side of the indoor unit using vacuum cleaner or flaping them lightly otherwise its performance will be affected the cool and dry conditions For Smart Use of The Air Conditioner Repla...

Page 7: ...NT PROHIBITION PROHIBITION PROHIBITION PROHIBITION Do not start or stop the operation by disconnecting Do not channel the air flow directly at people especially at infants or the aged Do not try to re...

Page 8: ...PC board is it with the type of T 3 15A 250V outdoor broken change it with the type of T 25A 250V Do not obstruct or cover the ventilation conditoner Do not put fingers inlet outlet and swing louver...

Reviews: