background image

Control panel

GB

GB

Use

Control panel

NO FROST

Refrigerator

Freezer

SMART

Power Cool

Power Freeze

Hold on

3 sec.

unlock

Hold on 3 sec.

holiday function

 

NO FROST

Fridge

Freezer

SMART

Power Cool

Power Freeze

 Lock

Hold 3 sec.

3 sec holiday

a

b

c1

c2

d

e

f

B

A

C

D

F

E

Before first use

 

Remove all packaging materials, keep them out of children`s reach and dispose 

them in an environmentally friendly manner.  

 

Clean the inside and outside of the appliance with water and a mild detergent before 

putting any food in it. 

 

After the appliance has been levelled and cleaned, wait for at least 2-5 hours before 

connecting it to the power supply. See Section INSTALLATION. 

 

Precool the compartments at high settings before loading with food. The function 

Power- Freeze helps to cool down the freezer compartment quickly. 

 

The refrigerator temperature and freezer temperature are automatically set to 5° C 

and 

-

18° C respectively. These are the recommended settings. If desired, you can 

change these temperatures manually. Please see ADJUST THE TEMPERATURE. 

Buttons:

A  Fridge selector 
B  Freezer selector 
C   SMART mode and holiday function selector
D  Power Cool selector
E  Power-Freeze selector
F  Panel lock selector

Indicators:

a  Temperature fridge
b   Temperature freezer
c1  holiday mode
c2  SMART mode
d  Power Cool function
e  Power Freeze function
f  Panel lock

  

Notice

 

The appliance is preset to the recommended temperature of 5°C (refrigerator) and    

- 18°C (freezer). Under normal ambient condition you need not to set a temperature.

 

When the appliance is switched on after disconnection from the main power supply, it 

may take up to 12 hours for the correct temperatures to be reached.

Empty the appliance before switching off. To switch off the appliance, pull the power cord 

out of the power socket.

  

Notice

The control panel is automatically blocked against 

activation if the doors are closed and 30 seconds no 

button is pressed. For any settings the control panel 

must be unlocked. 

10

11

Switch on /off the appliance

The appliance is in operation as soon as it is connected to the power supply.

When the appliance is powered on for the first time, the actual refrigerator and freezer 

temperatures are displayed. The display will flash. If the doors are closed it will switch off 

after 30 seconds.
Maybe the panel lock is active.

Standby-mode

The display screen turns off automatically 30 seconds after pressing a key. The display will 

be automatically locked. It lights up automatically when pressing any key or opening any 

door (Alarm does not light up the display screen). 

Sensor keys 

The buttons on the control panel are sensor keys, which already respond when lightly 

touched with the finger. 

Lock/unlock panel

  Lock

Hold 3 sec.

 

Touch button “F” for 3 seconds to block all panel el-

ements against activation. The buzzer alarms and 

the related indicator “f” is now displayed; the light-

ening of the panel is switched off. The icon flashes 

if a button will be pressed, when the panel lock is 

activated. The change is not running.

 

For unlocking press again the button. 

Summary of Contents for HRF-550FSS

Page 1: ...GB User Manual Refrigerator Freezer HRF 550FSS HRF 550FW HRF 550FGS HRF 550FB...

Page 2: ...r the safe and proper use of the appliance If you sell the appliance give it away or leave it behind when you move house make sure you also pass this manual so that the new owner can become familiar w...

Page 3: ...ppliance must be earthed Only for UK The appliance s power cable is fitted with 3 cord grounding plug that fits a standard 3 cord grounded socket Never cut off or dismount the third pin grounding Afte...

Page 4: ...inutes before restarting the appliance as frequent starting may damage the compressor WARNING Hold the plug not the cable when unplugging the appliance Do not clean the appliance with hard brushes wir...

Page 5: ...lass shelves 3 Rating plate 4 Humidity zone drawer 5 Door strip 6 Ceiling lamp 7 Blue light 8 Air duct and sensor behind panel 9 O K temperature indicator optional 10 Air duct behind drawers 11 Dry zo...

Page 6: ...gerator and 18 C freezer Under normal ambient condition you need not to set a temperature When the appliance is switched on after disconnection from the main power supply it may take up to 12 hours fo...

Page 7: ...is 5 C Colder temperatures mean unnecessary energy consumption If no key is operated in 5 sec the setting confirms au tomatically Door opening alarm When the refrigerator door is opened for more than...

Page 8: ...fresh food and protects the goods already stored from undesirable warming The factory setting temperature is 0 to 1 C 1 Unlock the panel by pressing button F if it is locked 2 Press button D Power Coo...

Page 9: ...on the packaging This indicates that the products might have been partially defrosted and refrozen at some point temper ature rises affect the quality of food Notice Please keep the distance more tha...

Page 10: ...y uplifting its hind edge 1 and pulling it out 2 2 To reinstall it put it on the lugs on both sides and push it to the most rearward position until the rear of the shelf is fixed inside the slots in t...

Page 11: ...stall the appliance in direct sunlight or in the near of heat sources e g sto ves heaters Avoid unnecessarily low temperature in the appliance The energy consumption in creases the lower the temperatu...

Page 12: ...tly Set the temperature higher until a satisfactory refrigera tor temperature is obtained It takes 24 hours for the refrig erator temperature to become stable Clean the door drawer gasket or replace t...

Page 13: ...ll Close the door drawer Do not open the door drawer too frequently Clean the door drawer gasket or replace them by new ones Reposition the shelves door racks or internal containers to allow the door...

Page 14: ...mm D2 930 mm W2 W1 D2 D1 WARNING The appliance is heavy Always handle with at least two persons Keep all packaging materials out of children s reach and dispose them in an environ mentally friendly ma...

Page 15: ...iance is used and where it is located Additional technical data Waiting time Tothemaintenance freelubricationoilislocatedinthe capsule of the compressor This oil can get through the closed pipe system...

Page 16: ...hat you have the following data available The information can be found on the rating plate Model _____________ Serial No _____________ Also check the Warranty Card supplied with the product in case of...

Page 17: ...HTF 456DM6_GB_V01_112015...