NOTICE
The power supply
for appliance is
220-240V, 50Hz
Single phase.
It is not
recomended
to use any
extention cords.
Connect the appliance
with a properly earthed three-wire
plug and socket with a special use.
Never store anything dangerous
in the appliance, such as
combustibles, exposives,
strong acid and alkali. etc.
SETTING UP
The appliance can be placed with its
rear panel directly against the wall.
For a good air circulation, the vent
grille at the back of the worktop must
not be blocked, It should be placed on
flat and firm ground lest it gives off
higher noise than usual.
Poorly ventilated rooms
are unsuitable. Avoid
positioning the appliance
in direct sunshine or
exposed to similar
sources of heat.
2
LAMP AND LAMP REPLACEMENT
7
ELECTRICAL DIAGRAM
Plug
Lamp
Switch
Thermostat
Starter
(PTC)
C
M
S
Compressor
Overload
Protector
Lamp: 220-240V,15W
Lamp holder: E14 (lamps exceeding 15W must not be used)
When replacing the lamp:
* Unplug to disconnect the power and remove the water tray.
Light Shade
* Press the positioning pin of the lamp
with left hand, and release the shade
from the lamp holder by sliding it
to the right side. Turn the lamp anti-
clockwise for removing.
* Replace the water tray.