Haier HIS-X76SWA1 Installation Manual/User Manual Download Page 11

10

 

Functional specifications

5min / ≤60

Functions

 

Function effect

time:20min

10min

90

42min

2 h / ≤50

time≥

20min

temperature≥60

Tense 

Cold meal

Dry

Warm-keep

Cup-warm

Dish-warm

Sterilize

Upper 

5min / ≤50

Working status

Chamber/Mode

Time/Temperature

chamber

Upper 

chamber

Upper 

chamber

Upper 

chamber

Lower

chamber

Lower

chamber

Lower

chamber

Ultraviolet

and

broadband

light

Ultraviolet

and

broadband

light

Ultraviolet

light wave

PTC hot air

PTC hot air

PTC hot air

time≥

temperature≥

Can kill the common intestinal 

pathogens, viruses in the kitchen, 

used for tableware sterilization.

Can kill the common intestinal 

pathogens, viruses in the kitchen, 

used for tableware sterilization.
To sterilize the surface of 

tableware, vegetables, fruits and

dried fruits at normal temperature.

For drying/dehumidifying tableware.

Warm-keeping for tableware and  food

For cups warm-keeping

For dishes warm-keeping

Lock

When the machine is on, press the button for 3 seconds to

the touch buttons on the 

control panel.Press the button again for 3 seconds to unlock the buttons on the control

 panel.

Sterilize

Door switch protection function: during the work of sterilizer, if the door is not closed,

the buzzer  will alarm,five minutes without closing the door, the sterilizer will be auto-

matically shut down.

Buzzer sound function: For effective operation, buzzer beep once; For invalid opera

-tion ,buzzer beep  twice;At the end of a normal function cycle, the buzzer beep heree 

times.

Intelligent tracking function: Touch the button, if 5 seconds without other operation, or

after a selected function is finished,the sterilizer will automatically turn into the tracking

sterilization state. In the process of intelligent tracking,  only the intelligent light flashes.

When the  intelligent  time arrives, the sterilization function starts and the power lamp 

is always  on. After the sterilization is completed, turn back to the intelligent tracking 

status, and the intelligent light will resume flashing status. To exit the Intelligent tracking 

function , just touch the "Intelligent" button.

Intelligent constant temperature function: during the operation of the selected program,

when the corresponding chamber temperature reaches the set temperature, the light 

wave tube will change from"continuous operation" change from "continuous operation

(heating)" to "intermittent operation (heating)" and automatically switch to the intelligent

constant temperature state.         

      

 

Summary of Contents for HIS-X76SWA1

Page 1: ...Sterilizer Model HIS X76SWA1 INSTALLATION GUIDE USER GUIDE ...

Page 2: ...1 CONTENTS 1 Instruction 3 2 Safety and warnings 4 3 Technical information Packing list 4 Installation instructions 7 5 Operating instructions 5 7 Troubleshooting 13 6 Cleaning and maintenance 12 9 ...

Page 3: ...2 Dear Customer sterilizer sterilizer ...

Page 4: ...lose the ability to replicate and at the same time make nuclear proteins coagulate to kill bacteria and viruses Broadband light wave pasteurization can heat microorganism instantly cause cellwall to break inactivate and die achieve the purpose of sterilization Suitable for sterilization of household utensils not suitable for sterilization of non utensils or medical purposes Names of principal comp...

Page 5: ...s into the sterilizer Please use a separate socket with rated current above16A and make sure ground reliably When pulling the plug from the socket you must hold the head of the plug to pull it out Not pull the power cord Otherwise it may cause dangers like electric shock short cir cuit etc Do not touch the glass surface and border of the door to avoid scalding hand The door of the cabinet can only...

Page 6: ...r Upper cavity Light wave lamp Power Main wavelength Ultraviolet lamp Power Wavelength Ultraviolet radiation illumination Capacity L Power of heater Dish warmer tempreture Product dimension Width Depth Height mm Net Gross weight Rated load capacity of each rack Average life of light wave lamp Average life of Ultraviolet lamp Lower cavity Name User manual APP Operation Instruction Set screw Quantit...

Page 7: ...nsor 1 Humidity sensor Upper door switch The upper door lock Ultraviolet sterilization lamp Ballast Light wave sterilization lamp Temperature limiter Thermostat PTC heater Ignitor M Fan Power supply board Temperature sensor 2 The upper door lock ...

Page 8: ...agram Installation must be more than 5 cm away from the gas or heating appliances or separated by a partition Before installation the strength and surface flatness of the installation site must be checked otherwise the machine may fall off and the cupboard door may be skew and misplace Power socket should be set within 0 3 meters next to reserved position of the sterilizer The impulse current is a...

Page 9: ...tallation 598 595 455 540 620 595 600 18 480 About dimension of sterilizer and cabinet Height of floor cabinet door plate 620mm when the height of local cabinet door plate is 620mm 580 560 it is recommended to add decorative strip on the top of sterilizer to ensure that the height of floor cabinet door plate is level with that of floor cabinet ...

Page 10: ...en the machine is ON the icon will be lit bright and the function icons of lower cavity is lit up or off in a cycle the three functions of Warm keep Cup warm and Dish warm are selected or cancelled respectively 5 seconds after the function selection and without further operation the corres ponding function of lower chamber starts to run When the lower chamber function intelligent tracking function...

Page 11: ... function during the work of sterilizer if the door is not closed the buzzer will alarm five minutes without closing the door the sterilizer will be auto matically shut down Buzzer sound function For effective operation buzzer beep once For invalid opera tion buzzer beep twice At the end of a normal function cycle the buzzer beep heree times Intelligent tracking function Touch the button if 5 seco...

Page 12: ...e sterilizer to avoid burns Rack instructions First to remove the fixing material and packing materials of accessories before use the Rack Attention After washing the dishes please drain the water first before put the dishes into the sterilizer however there is no need to wipe the dishes Because the surface moisture of the tablewares will be heated into steam with stronger heat penetration and bet...

Page 13: ... powder etc so as to avoid machine discoloration surface paint cracks Remove stains from the utensils To avoid peculiar smell inside the sterilizer before putting in the tableware the grease and stains on the surface of the tableware should be cleared up thoroughly In order to extend the service life please timely clean the cavity and the rack to remove the surface dirt water stains remaining wate...

Page 14: ...interference nearby The starter is broken Poor contact of the ultraviolet sterilization lamp The ultraviolet sterilization lamp or the door swith is broken The connector is not firmly connected The door is not closed well The light wave sterilization lamp or the door swith is broken Connect the electricity Change to reliable power supply Eliminate the source of electromagnetic interference Call th...

Page 15: ...tu on of original components with spurious non genuine components a acked by household pest rodents fire flood earthquake lightning and or any other act of God natural calami es c The product is shi ed outside India 12 a For any service under this warranty beyond city town municipal limits from the Company authorized service center a fixed charge of Rs 100 will be collected from the customer in addi...

Reviews: