Chapter 8 Trouble shooting   

8-1. Normal phenomena   

Problem 

Possible Causes 

What To Do 

Freezer does not 

operate or 
Power-On Light is 
not on 

Temperature control in OFF or 
Min or 0 position. 

Move the control to a temperature setting. 

Freezer is unplugged. 

Push the plug completely into the outlet. 

The fuse is blown/circuit 
breaker is tripped. 

Replace fuse or reset the breaker 

Freezer 

starts/stops too 
frequently 

Door/lid left open. 

Check to see if package is holding door/lid 

open. 

Too frequent or too long to 
door/lid openings. 

 

Temperature control set too 
cold. 

See About the operation of the freezer 

Freezer operates 

too long 

Door/lid left open. 

Check to see if package is holding door/lid 

open. 

Too frequent or too long 
door/lid openings. 

 

Temperature control set too 
cold.  

See About the operation of the freezer 

Inadequate air circulation 
space around cabinet. 

See Preparing to install the freezer 

Fast Freeze switch is in the 
ON position (on some 
models) 

See About the operation of the freezer 

Noisy operation or 

cabinet vibrates 

Floor may be weak, causing 
freezer to vibrate when 
compressor is on. 

Placing 2 X 4s (51 mm X 102 mm) under the 

length of the freezer will help support it and 
may reduce vibration. 

Cabinet is not positioned 
solidly on floor 

See Preparing to install the freezer Or use 

shims for uneven floor 

Freezer 

temperature too 
warm 

 

Door/lid left open. 

Check to see if package is holding door/lid 

open. 

Too frequent or too long 
door/lid openings. 

 

 
Foods defrosting 
 
 
 

Temperature control OFF or 
Min or 0 positions. 

Move the control to a temperature setting. 

Freezer is unplugged. 

Push the plug completely into the outlet. 

Summary of Contents for HF50CW10W

Page 1: ...and is not designed for use by the general public It dose not contain warnings and cautions to advice non technical individuals of potential dangers in attempting to service a product Product powered by electricity should by serviced or repaired only by experienced professional technicians Any attempt to service or repair the product or products dealt with in this service information by anyone els...

Page 2: ...ing 7 3 3 Cleaning the Freezer 8 Chapter 4 Disassembly 9 4 1 Door assembly Door hinge hinge cover 9 4 2 Compartment Grill assembly 9 4 3 Control panel assembly Panel cover board knob indicator light 9 4 4 Thermostat assembly 10 Chapter 5 Control and display system 11 5 1 Control panel 11 5 2 Starting the Freezer 11 Chapter 6 System flow principle 12 6 1 Refrigeration flow chart 12 6 2 Refrigeratio...

Page 3: ...ith any kinds of instruments 5 Watch if the upper door is open when we check something at a lower position 6 Take out every part in the cabinet before moving the machine especially things like panels e g glass shelf 7 Please wear intact cotton gloves when repair any parts of the evaporator so that scratches by the sharp fins can be avoided 8 If there is a breakdown with the refrigeration system pl...

Page 4: ...nd photos used in this Manual may not base on the final design of products which may differ from the products in some way 1 3 How to read this Service Manual Icons are used to attract the attention of the reader to specific information The meaning of each icon is described in the table below Note A note provides information that is not indispensable Caution A caution is used when there is danger t...

Page 5: ... R141b C P C P 3 Technical data Voltage frequency Compressor brand V Hz 115V 60Hz Input power currency W A 1 69A Length of cable incl plug cm 150 155 Lowest Temperature C 18 C Energy consumption EN153 per year kWh year 240kW h year Cooling system K Compressor A Absorbtion K 4 Aesthetics Lid Shape straight edges Lid Coulour white Cabinet Shape straight edges Cabinet Coulour white Frame of the cabin...

Page 6: ...SERVICE MANUAL Model HF50CW10W 6 Issue 2014 1 24 Rev Ref1401S002V0 2 2 External views Door Cabinet Control panel Drain pipe ...

Page 7: ...y about twice a year To have the freezer operate most efficiently do not permit more than 1 2 13 mm of frost to accumulate on the shelves To remove frost scrape with a plastic or wood spatula or scraper Do not use an ice pick or sharp edged instrument as it may damage or scratch the freezer Do not use any electrical device in defrosting the freezer For Complete Defrosting 1 Turn the temperature co...

Page 8: ...h wax or mild liquid dishwashing detergent Dry and polish with a clean soft cloth Do not wipe the freezer with a soiled dishwashing cloth or wet towel Do not use scouring pads powdered cleaners bleach or cleaners containing bleach Inside Clean the inside of the freezer at least once a year We recommend that the freezer be unplugged before cleaning If this is not practical wring excess moisture out...

Page 9: ...ull it and then unscrew the screws on the hinge so the whole hinge could be moved 4 2 Compartment Grill assembly Unscrew the two screw of grill we can take away the grill 4 3 Control panel assembly Panel cover board knob indicator light Unscrew the compartment grill refer 4 2 push the panel claw gently with our finger or tools at the same time pull panel outside then take away it Top hinge cover B...

Page 10: ...ke it away Press two claws on indicator light side and push it from back to front 4 4 Thermostat assembly First take off the knob refer 4 3 Use turnbuckle spanner or acutilingual plier unscrew the turnbuckle and then thermostat can be moved from back of panel Note When assembly thermostat we should placed thermostat in originally direction ...

Page 11: ... step adjustment for the freezer temperature to stabilize 5 2 Starting the Freezer 1 Clean the inside of the freezer with a mild solution of baking soda and water 2 Connect cord to power outlet 3 On models with a Temperature Monitor or High Temp Alarm Switch set the switch to the Min position 4 Make sure the temperature control is set at 4 5 Allow freezer to operate for at least four hours before ...

Page 12: ...inciple 6 1 Refrigeration flow chart The refrigeration system of direct cooling single system cooler belongs to the category of a single temperature and single control refrigerating system with one evaporators and is controlled by a single temperature control 6 2 Refrigeration flow scenograph ...

Page 13: ...SERVICE MANUAL Model HF50CW10W 13 Issue 2014 1 24 Rev Ref1401S002V0 Chapter 7 Circuit diagram 7 1 Brief principle diagram HF50CW10W ...

Page 14: ... door lid open Too frequent or too long door lid openings Temperature control set too cold See About the operation of the freezer Inadequate air circulation space around cabinet See Preparing to install the freezer Fast Freeze switch is in the ON position on some models See About the operation of the freezer Noisy operation or cabinet vibrates Floor may be weak causing freezer to vibrate when comp...

Page 15: ...els About the operation of the freezer Moisture forms on outside of cabinet Not unusual during periods of high humidity Wipe surface dr Interior light does not work on some models No power at outlet Replace fuse or reset the breaker Freezer is unplugged Push the plug completely into the outlet Light bulb burned out Replace bulb Door lid wont fully close by itself Package holding door lid open Slow...

Page 16: ... current of compressor is higher than 120 of normal operating current If the noise of compressor is loud Check whether the working current of compressor is lower than 80 of normal operating current The working sound of compressor is small If compressor can run naturally and temperature raising of condenser is very low If the temperature raising of condenser and drier filter is very low Both high p...

Page 17: ...e capacitor from circuit firstly and then connect two terminals for discharge 1 IF the finger of multimeter swings to 0 quickly and then swings back slowly when measuring two poles of capacitor it means the run capacitor is normal 2 If the finger of multimeter does not swing it means the run capacitor is open circuit If the finger of mlimeter swings to 0 and stops means it is short circuit if it s...

Page 18: ...er the pipeline does resonate Thecapillary tube is not smooth or has burr Is the freezing evaporator is fixed tightly Refilling Add shock damper glue or fix the evaporator tightly Adjust distance to more than 5mm Adjust and fix bolts or fixing clip Replace rubber damper cushion Adjust and fix Adjust pipeline or add shock damper glue Adjust appliance and explain to user Explain to user Exterior fac...

Page 19: ...Sincere forever Haier Group Haier Industrial Park No 1 Haier Road 266101 Qingdao China http www haier com ...

Reviews: