After care
GENERAL ADVICE
For best results, use cooking vessels with a flat
surface. The size of the surface should match
the gas burner side as follows. Table A:
Maintenance and cleaning
• Before cleaning the hob, ensure the appliance
has cooled down.
• Cleaning and user maintenance shall not be
made by children without supervision
•When cleaning the enamelled, varnished or
chrome sections, use warm soapy water or a
non caustic detergent. For stainless steel use
an appropriate cleaning solution.
•Remove the plug from the socket or (if
connected directly) switch off the electricity
supply.
• Never use abrasives, corrosive detergents,
bleaching agents or acids. Avoid any acid or
alkaline substances (lemon, juice, vinegar etc.)
on the enamelled, varnished or stainless steel
sections.
Chromed grids and burners
• It is important the Burners are replaced
correctly.
Chromed grids and burners have a tendency to
discolour with use. This does not jeopardize the
functionality of the hob
Our After Sales Service Centre can provide spare
parts if required.
• The burners can be cleaned with soapy water.
To restore their original shine, use a household
stainless steel cleaner. After cleaning, dry the
burners and replace.
Before calling out a Service Engineer please
check the following:
• That the plug is correctly inserted and fused
If the fault cannot be detected:
• Switch off the appliance and call the After
Service Centre. DO NOT TAMPER WITH THE
APPLIANCE.
• That the gas supply is not faulty
The manufacturer will not be responsible for any
inaccuracy resulting from printing or transcript
errors contained in this brochure. We reserve the
right to carry out modifications to products as
requires, including the interests of consumption
without prejudice to characteristics relating to
safety or function.
Burner type
Ø pan/
pot (cm)
Power
(kW)
G20/20
mbar
(methane)
G 30/28-30
mbar (LPG)
AUX
Auxiliary
SR
Semi Rapid
1.5 kW
R
Rapid
DC 4,2 kW
MONO
DC 5 kW
MONO
10-18
12-22
16-26
16-26
16-26
1,00
1,50
2,70
4,2 NG
4 LPG
5 NG
4,6 LPG
95 l/h
143 l/h
257 l/h
400 l/h
476 l/h
73 g/h
109 g/h
196 g/h
291 g/h
334 g/h
WARNING: If a flame is accidentally extin-
guished, turn the knob to the off position and do
not attempt to re-ignite if for at least 1 minute.If
over the years the gas taps become stiff to turn
it is necessary to lubricate them.Such operation
must be carried out only by qualified Service
Engineers.
For smaller containers the gas burner should be
regulated so that the flame does not over-lap
the base of the pan. Vessels with a concave or
convex base should not be used.
EN 11
SR
Semi Rapid
1.75 kW
12-22
1,75
167 l/h
127 g/h
Summary of Contents for HAHG6
Page 1: ...HAVG6 HAVG7 ...
Page 87: ...42835347 09 2020 Rev_C ...