Emergency and Test  Operation

 Use this operation only when the remote controller is defective or lost.

When the emergency operation switch is pressed,the" Pi "sound is heard once, which
means the start of this operation.

In this operation, it is possible to change the
settings of temperature and air flow speed, it is
also impossible to do an operation by the timer.

Operation

Emergency operation:

Follow the requirements below.

    Room
temperature

Designated

temperature

Timer
mode

Air flow
speed

Operation
    mode

More than 23

o

C

Less than 23

o

C

 23

o

C

 26

o

C

CONTINUOUS

CONTINUOUS

AUTO

AUTO

COOL

HEAT

If an air conditioner is a model for both cooling and heating.

Cooling when the room temperature at the start of operation is above 23

o

C.

temperature is less 16

o

C, do not use it in the normal

Use this switch in the test operation when the room

operation.

operation starts with the air flow speed setting "Hi".

Continue to press the test operation switch for more
than 5 seconds. After you hear the "Pi" sound twice,
release your finger from the switch, the cooling

Removal of the restriction of emergency or test operation:

Press once more the emergency operation switch, or manipulate through the remote
controller, a "Pi" sound causes the restriction of emergency or test operation to be
removed.
When the remote controller is manipulated for the removal, then the selected operation
by the remote controller.

Heating when the room temperature at the start of operation is below 23

o

C

Test operation:

Summary of Contents for H2SM-18R04

Page 1: ...SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL Please read this operation manual before using the air conditioner...

Page 2: ...erials collecting centers and waste paper disposal services nearest to your house Disposal of the packaging of your new air conditioner Safety Instructions and Warnings 1 Cautions All the packaging ma...

Page 3: ...t fingers or any other things into the inlet outlet and swing louver Do not allow children to play with the air conditioner In no case should children be allowed to sit on the outdoor unit The refrige...

Page 4: ...r m a l o p e r a t i o n U s e r e m o t e c o n t r o l l e r t o a d j u s t u p a n d d o w n a i r f l o w D o n t a d j u s t i t m a n u a l l y I n l e t g r i l l e Vertical louver Horizontal...

Page 5: ...iring standard 6 After installation the power plug should be easily reached 7 The waste battery should be disposed properly 8 The appliance is not intended to use by young children or infirm persons w...

Page 6: ...u rd e s i r e dt e m p e r a t u r e 22 FAN Used to select fan speed 23 POWER ON OFF Used for unit start or stop 24 SLEEP Used to select sleep mode L O W M E D H I A U T O 25 SWING 26 SET U s e d t o...

Page 7: ...ontroller Parts and Functions If the unit which you purchased has not health function remote controller should like the following figure 1 Mode display AUTO COOL DRY HEAT FAN 2 SWING display 3 FAN SPE...

Page 8: ...questasillustrated Put on the cover again Confirmation indicator Indisorderation reloadthebatteriesorloadthenewbatteries after 6 mins Note Use two new same typed batteries when loading Iftheremotecont...

Page 9: ...Only time remains on LCD Allindicatorsonindoorunitgoout Verticalflapclosedautomatically Hints Remote controller can memorize settings in each operation mode To run it next time just selecttheoperatio...

Page 10: ...gtoreachthetemp settingonLCD Press FAN button For each press fan speed changes 4 Fan speed selection asfollows justpressON OFFbuttonandunitwillruninpreviousstatus Unit runs at the speed displayed on L...

Page 11: ...oveyourfatigue Morethanthis unit sloadcanbereducedandpowerconsumptioncutdownaswell So you d 6 Unit stop Press ON OFF button Only time remains on LCD Allindicatorsonindoorunitgoout Verticalflapclosesau...

Page 12: ...3 Timer setting Every time the button is pressed time increases 10 min Ifbuttoniskeptdepressed timewillchangequickly Every time the button is pressed time decreases 10 min Ifbuttoniskeptdepressed tim...

Page 13: ...0 min If button is kept depressed time will change quickly Every time the button is pressed time increases 10 min It can be adjusted within 24 hours Time will be shown on LCD AM refers to morning and...

Page 14: ...function stops The anion generator in the air conditioner can generate a lot of anion to effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the d...

Page 15: ...for both cooling and heating Cooling when the room temperature at the start of operation is above 23 o C temperature is less 16 o C do not use it in the normal Use this switch in the test operation w...

Page 16: ...y3hourslater Temp islower than temp setting so that room temp won t betoohighforyoursleep Power Failure Resume Function withtheindicatorlightingup Iftheunitisstartedforthefirsttime the compressorwilln...

Page 17: ...th Don t use glass cleaner or cloth soaked with chemicals 1 Openinletgrillebypullingitupward A i r F i l t e r 2 Removeairfilter Pushupthefilter scentertab slightlyuntilitiscaesuraof the stopper Remov...

Page 18: ...e bacteria killing medium air purifying filter to be washed The air purifying filter of multi lights touching intermediary will be solarized in fixe time In normal family it will be solarized every 6...

Page 19: ...er fail to observe the followings Do not sprinkle water over the unit Do not block the inlet or outlet Do not pull power plug Do not use for other purposes Such as food preservation plantcultivationor...

Page 20: ...Thisnoiseisgeneratedby refrigerantflowinginthesystem During unit operation a cracking noise may be heard This noise is generated by the casing expanding or shrinking because of temperature changes Sho...

Reviews: