Model Number

Personality ID 

SSD

Personality ID 

Cycle Status LEDs

GTW220**K0 / K1 / K2 / K3

10

GTW220**K4 / K5 / K6

1

GTW330**K0 / K1 / K2 

11

GTW330**K3 / K4

2

GTW335**N0 / N1

15

GTW460**J0 / J2 

14

GTW460**J3 / J4 / J5 / J6  / J7

12

GTW460**J8 / J9 / JA

3

GTW465**N0

16

GTW465**N1 & higher

18

GTW485**J0 / J1 / J2 / J3 / J4 / J5

4

GTW490**J0 / J1 / J2 / J3 / J4 / J5 

5

GTW500**N0 & higher

17

HTW200**K0 / K1 / K2

9

HTW200**K3 / K4

0*

HTW240**K0 / K1 / K2

10

HTW240**K3 / K4 / K5

1

Note: 

For models HTW200**K3 and K4, the cycle status LED’s 

will not be lit for 

personality “0”.

*

2

Note: Solid 

circles indicate 

that particular 

cycle status LED 

is lit. 

FIELD SERVICE MODE ENTRY

From an idle state only (all LEDs off), press and 
hold 

Start 

button while rotating the cycle selection 

knob 180 degrees (7 clicks) and then release the 

Start 

button.

• Once service mode is entered all LEDs will be 
flashing.
– On 7-segment display models: (0) will be 
displayed for Test (0).
– On models without a 7-segment display: All of 
the status LEDs above the cycle knob will be lit.

• The cycle selection Knob is now used to control 
the test selection menu.

– Rotating the knob clockwise will increment 

the test numbers in the
display.

– Rotating the knob counter clockwise will 

decrement the test number in the display.

– Models without 7-segment display: Will 

display tests using the status lights above the 
cycle knob in a binary format. (See Binary Chart)

– Turning the knob to go to a different test will 

terminate any current active state.

• Once the test number is selected, pressing 

Start 

will 

begin the selected test.

Exit Field Service Mode

• Field service mode will time out after 30 minutes if 
there is no user activity.

• Models without 7-segment display: Press and hold 
the 

Start 

button for 3 seconds

• Models with a 7-segment display: Press 

Power 

button

SERVICE MODE TEST 17-
Change Personality  

Pressing 

Start 

will start the test. Press 

Start 

button 

again and the next valid personality should be 
displayed. Press and hold the 

Start 

button to select the 

correct personality. The control will go to an idle state. 
All LED’s off.

Note: 

Upon entering test 17 for models,

HTW200**K3 and K4, the cycle status LED’s 

will not 

be lit for personality “0”.

Note: 

If the personality ID is already set and you try 

to set the same personality, the control will NOT go to 
an idle state. Ensure the correct personality ID is 
being entered. 