– 11 –
NOTES
:
The previous chart has maximum segment parameters listed. The control will bypass some rinse
cycles if the turbidity sensor detects lower soil than the selected cycle maximum parameter, and
temperature targets are met.
Selecting the Wash Temp option will add 5 minutes to Pre-Wash 4 (PR4) and Post-Rinse 1 (PW1).
This extra time is used to heat water.
The Sani/Steam option will change the segments Pre-Wash 4 (PW4), (increasing heater operation).
The Bottle Wash option (on some models) may increase the cycle time, adding up to 23 minutes;
water usage does not change.
Circulation has built in pauses (see
Diverter
,
Operation
in the
Circulation System
section of this
guide).
USA
(Upper Spray Arm): When a number is placed before the USA, it indicates the approximate
time in seconds of operation.
LSA
(Lower Spray Arm): When a number is placed before LSA, it indicates the approximate time in
seconds of operation.
PW
: Pre Wash
PR
: Post Rinse
FR
: Final Rinse
Normal with Heated Dry
Time
Calrod Description
7
Calrod on
27
Calrod Pulse - 2 minute on/1 minute off
14
Calrod off - Cool Down
7
Calrod on
57
Calrod Pulse - 1 minute on/1 minute off
Boost Dry Option
7
Calrod on
57
Calrod Pulse - 2 minute on/1 minute off
15
Calrod off - Cool Down
Cycle
PW4
MW
Rinse
FR
125
130
135
Normal
125
140
Auto
130
130
140
Heavy
130
130
130
145