2
To reset the CSM. (
GE Technicians use Laptop Diagnostics Program)
Entering Service Mode will reset the CSM.
To enter
Service Mode
:
1. First enter
Consumer Error
mode as directed previously. After the ten (10) second door check
has completed, continue to next step.
2. Enter
Service mode
(while in Consumer Error Mode), by pressing and holding the
Select Cycle
button for five (5) seconds.
Fill, circulate, heater and drain tests can be selected by using the
Select Cycle
button. To start each
test, press the
Start
button.
Complete Consumer Error and Service Mode details may be found in the mini-manuals or Service
Guides.
Replace the Heating Element with
WD05X24776 (Exposed Heater models only)
GE Technicians will use laptop diagnostics to diagnose and view load snapshot at time of trip
and to update software.
Customer Care Technicians will use SUM Module
WD98R2327901