background image

 

12

Circuit Wiring 

(New Zealand, Australia, Cyprus)

 

 

 

 
Circuit Wiring

 

(America and Canada) 

 

 

Summary of Contents for GDZ5-1

Page 1: ...1 HAIER Front Loading Dryer Service Manual PART WD 8888 22 HAIER AMERICA TRADING LLC www haieramerica com ...

Page 2: ...2 Table Of Contents Features 3 Specifications 4 Safety Caution 5 Unpacking And Installation 7 Troubleshooting 8 Dimensions 11 Names Of Parts 11 Circuit Wiring 12 ...

Page 3: ...ng cycle heat cool and synthetic The support of front and rear make running balanced low noise Straight exhaust of back inhale styled make good airproof and high drying efficiency After heat drying cool may protect clothes ...

Page 4: ... Signal No Wrinkle Remover Tumble No Easy Access Lint Filter Yes Interior Drum Light No Dryer Rack No Easy Opening Wide Door 10 6inch Dry Cycles 2 kinds Fabric Care Drying Cycles Temperature Aegis Permanent Press No Side Exhaust Vents No LP Conversion Kit Serviceable Front Rear End Dimensions Width 23 4inch Depth with Door Close 22 8inch Depth with Door Open 36 6inch Height Height with Back Guard ...

Page 5: ...el should clean exhaust duct approximately every 18 months An excessive amount of lint build up in these areas could result in inefficient drying and possible fire See care and cleaning WARNING Do not operate the dryer if the lint screen is blocked damaged or missing Fire hazard overheating and damage to fabrics can occur WARNING Keep area around the exhaust opening and surrounding areas free from...

Page 6: ...ATION INSTRUCTIONS for detailed grounding procedures Never ground the dryer to a gas pipe If the dryer is moved to a new location have it checked and reinstalled by a qualified service person WARNING Always disconnect the dryer from the electrical supply before attempting any service or cleaning Failure to do so can result in electrical shock or injury WARNING Do not use any type spray cleanser wh...

Page 7: ...but a space of at least 3 9inch at the dryer back should be left to facilitate air exhaust c An extension pipe can be mounted at the request of the user according to the above steps The dryer should be near the window through which the user pulls the extension pipe to exhaust the humid and hot air in the room At the end of the use replace the extension pipe d At the request of the user make a hole...

Page 8: ...r is closed check the program controller Replace it if it does not work Maintenance Procedure 1 Loosen the screws on the deck plate at the back and remove the deck plate 2 Take out the timer knob unscrew the timer with a screwdriver and pull out the timer connecting wire 3 Replace the timer and turn on the power If the dryer operates normally mount the deck plate B The program knob of the dryer po...

Page 9: ... remove the heater then pull out the power line of the heating pipe from its location hole 3 Replace the heater and then turn on the power and check the heater If the operation is normal mount the back cover again D The program knob of the dryer points at the blue zone the cold air indicator is on and the drum rotates The fuse is turned off E After a program is selected and the dryer is started th...

Page 10: ...is opened otherwise the installation is not proper Check to see if the dryer operation is normal according to the above procedure G Great operating noise is heard accompanied by abnormal noises After opening the back cover and removing the belt the noise still exists Impeller falls off or is damaged Maintenance Procedure 1 Open the back cover and remove the belt pull out the power line clip and po...

Page 11: ...11 Dimensions Names of Parts ...

Page 12: ...12 Circuit Wiring New Zealand Australia Cyprus Circuit Wiring America and Canada ...

Reviews: