Instruction 
   manual 
   (Copy)

 
   (Copy)

Check 

valve

(Pc)

Pipe fitting

Components

Quantity

Model

Electric 

water heater

(Set)

Relief valve / 

drain hose

(Set)

3/4

airproof 

met

(Copy)

2

2

2

2

Packing list Special hints

Packing list

Special hints

Be sure to disconnect the power supply before performing any maintenance or repair 
work on it. Only professionals should be allowed to adjust or repair the water

Make sure the water heater is fully filled with water before turning on the power. 
Otherwise malfunction of the heating element may occur. Please make sure the power 
socket complies with applicable national standards and is reliably grounded. Never use 
the water heater without reliable earthing.

The water heater is fitted with a relief valve. To ensure safety, please do not change its 
installation location and never block its outlet.

When the ambient temperature is under 0

, the piping may be damaged due to freezing 

of water in it and cause the water heater to malfunction. So you shall drain the water in 
the tank to avoid freezing. If the water heater is not to be used for a period of over 1 
month, 

If the electrical water heater is seriously soaked with water, it must be examined and 
repaired by a technician authorized by the manufacturer before it is put into use again.

Scale can be formed in the water tank after long periods of use. Besides, water quality 
may change due to ageing of the water pipe. After you wash rice or vegetables with 
water from the water heater, please rinse them with clean tap water.

Do not place flammables such as gasoline near the water heater to avoid fire or other 
accidents.

please unplug the power cord and drain the water tank.

5

6

Installation methods

Precautions during installation

Be sure to have it installed by the installation staff from the after-sales service center of 
the manufacturer or a center authorized by them. It adopts floorstanding installation.
Locate the water heater and install all the pipes with a tap water tube (PP-R pipe is 
recommended) according to the dimension diagram and the user's requirements. 
Mount the relief valve and other accessories according to Fig. 1. Remember to use 
Teflon seal tape to avoid leakage.
To facilitate installation and dismantling of the water heater, it is recommended to fit a 
G1/2

at the suitable location on the water inlet pipe and outlet pipe 

separately. Confirm the positions needing water supply and connect the water inlet 
pipe, outlet pipes and tap water pipes to the locations separately.
Note:The hot water pipe shall not be too long to reduce the heat losses.
When installing the water heater, please reserve certain space to facilitate future 
maintenance and repair. Fig. 1 is only a reference installation schematic of pipelines. 
In specific installations, the actual situation of the user should be considered.

 flexible nut 

Installation methods

Precautions during installation

City water inlet pressure shall not be less than 0.05 MPa.
Electric water heater shall be installed indoors with ambient temperature above 0

. The 

pipes shall be collectively laid. Hot water outlet shall not be too far from use points. In case 
farer than 8 m, hot water pipe shall have a thermal insulation to minimize heat loss.
Electric water heater shall be located in a place easy for use, maintenance and with a floor 
drainer. In case the tank or pipes leak, nearby or lower facilities shall not be damaged. 
Power socket for water heater shall be in a dry place free of water splash. (splash-proof 
box is preferred).
Do not confuse inlet and outlet water pipes. Safety valve shall be installed at designated 
position with no random modification. 

Connection and use of the check valve:
Connect the check valve with G1/2  connection screw according to the arrow on it.

Fig.1

Hot water outlet

Safety vaive

Indicator lamp

Check valve

Blowdown port

Hot water 
outlet valve

Cold water 
outlet valve

Summary of Contents for FCD-JTLD100

Page 1: ...Sea ox King Haier Household Electric Water Heater Please read this manual before usage Retain it for future reference 0040502123 vc FCD JTLD80 FCD JTLD100 FCD JTLD120 FCD JTLD150 ...

Page 2: ...uture reference The international star service of Haier Group will always accompany you No matter what kind of problems you meet in usage please contact with the local after sales service agent We are at your service all the time Thanks again for choosing Haier Product The water heater you purchased may not full comply with the manual due to the improvement of product We apologize for the inconven...

Page 3: ...nsion diagram Appearance and components 1 1 2 3 4 5 10 7 8 Precautions during use 7 Safety precautions Setting environment Technical data Cleaning and maintenance 8 Special hints Precautions during installation 5 6 Installation instructions Installation methods 6 7 8 9 9 10 See to thephysical product forthe appearance coloror pattern ...

Page 4: ... adopts dusting anticorrosion treatment handsome and durable enamel tank L N E BT HL EH MT L Brown wire N Blue wire temperature limiter Thermostat eating indicator EH Heating element E Yellow green wire MT High BT HL H Connected to inner tank 10 FAQ FAQ Phenomenon Please check Solutions No water outlet Cold water outlet only If the water supply system stops supplying water or the water pressure is...

Page 5: ...iption of the symbols This symbol indicates actions you shall never do Neglecting these instructions may cause personal injury or even death This symbol indicates instructions you must observe Neglecting these instructions may cause personal injury or damage to your house or property Safety precautions Note the allowed error range of above parameters is 10 8 9 Heat preservation layer Magnesium ano...

Page 6: ...e as the temperature is too high Please call the after sales service center in this case Please keep away from the drain hose during use to avoid scalding 99 Cleaning and maintenance To clean the outside Disconnect the power supply before cleaning the water heater Wipe it lightly with a piece of wet cloth dipped in a little neutral detergent other than gasoline or other solutions Then wipe it with...

Page 7: ...ate degree before use Water over 50 can result in scalding The relief valve should be checked once every two weeks during use The method turn the small handle of the relief valve It is normal if there is water flowing from it If not please contact local after sales service center The product is a water heater of enclosed type It can supply hot water to several locations such as bathroom bathtub ha...

Page 8: ... a center authorized by them It adopts floorstanding installation Locate the water heater and install all the pipes with a tap water tube PP R pipe is recommended according to the dimension diagram and the user s requirements Mount the relief valve and other accessories according to Fig 1 Remember to use Teflon seal tape to avoid leakage To facilitate installation and dismantling of the water heat...