background image

 

NOTE: 

THE PART    MAY NOT BE USED.

1 BECAUSE OF DIFFERENT COMPRESSOR

G: GREEN

250VAC

T3.15A

B

BL

R

4

CAPACITOR

FAN MOTOR

L

H

COMPRESSOR

S

R

PROTECTOR

HEAT

C

TRANSFORMER

FUSE1

BL: BLUE
BR: BROWN

B: BLACK

Y: YELLOW

W: WHITE

R: RED

WIRING DIAGRAM

ROOM

SENSOR

PIPETEMP.

SENSOR

W

CN2

CN4

NO

C

SWITCH

FLOAT

W(BL)

BL

B

BL

BL

R

(

0

R

)

CN8

CN7

CN11

CON1

CN1

TEMP.

HI

LOW

3

CN6 CN5

DCF

CN10

N

B(BR)

G(Y/G)

CONTROL
 BOARD

1

1

2

2 BECAUSE OF DIFFERENT MODELS

THE PART    MAY NOT BE USED.

0010512580

NC

HERM

FAN

C

W

M

M

M

Y

2

CN3

SENSOR

HUMIDITY

B

1

3

Summary of Contents for Fan

Page 1: ...2014 DE45EM DE45EM T DE45EM TC DE45EM E DE65EM DE65EM T DE65EM TC DE65EM E AC1011S004V0...

Page 2: ...8 0 1 3...

Page 3: ...M...

Page 4: ...nts 180 150 57 56 11 15 R410A 7 4Oz 4 2 480 690 21 13 3 8 10 5 8 22 1 2 14 3 4 12 16 8 18 6 17 7 18 6 910 740 14 16 1 2 25 3 16 12 15 23 1 2 6 2 R410A 8 1Oz 57 56 220 200 65 Prints Unit Dimensions 1 8...

Page 5: ...3...

Page 6: ...NO other extension cord is permitted...

Page 7: ...to the direct drain opening Fig 2 3 Position the dehumidifier as close as you can to the floor drain 5 When the direct drain feature is not being used remove the drain hose from the direct drain open...

Page 8: ......

Page 9: ...rned on and off by pressing the SIGNAL button The default setting is set in the ON position When the bucket is full the red BUCKET FULL indicator light will blink and the alarm will sound 5 times ever...

Page 10: ...8...

Page 11: ...9...

Page 12: ...0 dehumidify evaporator condenser...

Page 13: ...1 27 PTD4 T1CH0 28 PTA5 29 RST 30 PTA7 31 ADC12 32 IC1 MC68HC908JL8CSPE SDIP32 5V C7 0 1uF 5V 5V P I P E H U M I D I T Y R O O M C O M P L O W H I V A L V E F U L L V 5 D N G 1 2 CN23 TJC8 2 DATA OSC1...

Page 14: ...2 IC3 ULN2003 SOP16 CN5 D187 8A CN6 D187 8A 1 2 3 4 5 6 7 8 9 0 1 CON1 480mm 10 B10B PH 5V R C RC1 300V 120 103 R C RC2 300V 120 103 1 CN9 D250 10A 1 CN10 D187 8A 1 1 CN8 D187 8A 1 CN7 D187 8A P I P...

Page 15: ...BR BROWN B BLACK Y YELLOW W WHITE R RED WIRING DIAGRAM R O O M S E N S O R P I P ET E M P S E N S O R W CN2 CN4 NO C S W I T C H F L O A T W BL BL B BL BL R 0R CN8 CN7 CN11 CON1 CN1 T E M P HI LOW 3 C...

Page 16: ...c Air Conditioner Sincere Forever Haier Group Haier Industrial Park No 1 Haier Road Edited by GuanLi DingCheng 266101 Qingdao China Signed by WangRuoFeng Tel 86 532 88936935 Approved by ZhangPeng Http...

Reviews: