Temperature setting
In active state (figures on display do not flash), press  

  

and  

  

to set temperature with the set 

temperature ranging from 35

 to 75

. Press  

   

or  

   

once, then for the temperature to be set 

add  or  reduce  1.  The  temperature  to  be  set  will  continuously  increase  or  decrease  under 
continuous  pressing  with  the  figure  circulating  35

  to  75

.  When  setting  temperature,  current 

set temperature figure flashes. If there is no operation within 6 seconds or the temperature is set 
by  directly  pressing  SET  key  to  confirm  the  desired  temperature,  set  temperature  figure  will 
become constant lighting state from flashing, indicating the completion of temperature setting.
Note: if keys other than SET are selected when the figure flashes (within 6s), the current setting 
does not work and the figure returns to the original state before setting. 
For  example:  the  current  set  temperature  of  the  heater  is  40

,  now  the  temperature  will  be 

adjusted to 55

. (As shown in Figure 6)

8

6

Please fasten the drain hose to the pressure relief hole of 
safety  valve  by  twisting  (see  to  Figure  4).  Connect  the 
other end of drain hose to the sewer to avoid polluting the 
room  by  splashing.  When  the  power  is  switched  on,  and 
the  water  heater  starts  operating,  there  may  be  some 
water discharged from the pressure relief hole of the safety 
valve. It is due to the water expansion under heating, and 
is  normal  phenomenon.  The  pressure  relief  pipe  shall 
communicate with the air directly. Do not block it. The drain 
hose  connecting  to  safety  valve  shall  be  kept  downward 
sloping in installation and in a frost-free environment.

Safety precautions:
1.

Do not confuse the water inlet and outlet pipes. The water bearing the water heater shall be 
strong enough to endure a weight twice as much as that of water heater filled with water. Do 
not secure it by means of adhesive or similar products because the fixation by such methods 
is unreliable.

2.

To  avoid  danger  caused  by  accidental  reset  of  heating  breaker,  the  power  for  the  heater 
cannot  be  supplied  by  timer  and  other  external  switch  devices  or  connected  to  circuit  with 
frequent switching for facility use.

3.

If any part is damaged, please contact the local maintenance agent and have it replaced with 
our spare part.

4.

Tap water inlet pressure shall be no less than 0.05MPa and the maximum pressure shall not 
exceed 0.75MPa.

Connect to drain hose

(Figure 4)

During  heating,  water  may  drip  from  the  drain  hose  of  the  pressure  relief  hole  due  to 
expansion  and  the  hole  must  be  left  open  to  the  atmosphere.  Check  safety  valve  once  a 
month  as  follows:  move  the  small  handle  of  safety  valve,  if  there  is  water  flowing  out,  safety 
valve is normal; if there is no water flow, please contact local after-sales service station.
The pressure relief hole is to be operated regularly to remove lime deposits and to verify that it 
is not blocked.

Installation

Attentions in installation

Installation

  

Attentions in installation

 

 

Introduction of control panel

Introduction of control panel

1

2

3

4

5

6

7

8

9

10

11

Be sure to check and confirm that the tank is filled with water, there is no leakage at each joint 
and the power supply complies with the stipulation before switching on the power.

7

Usage

Usage

After installation, as the tank is empty in the first usage, be sure to open the tap water inlet valve 
and any outlet of the heater. When the tank is filled with water or other water outlet keeps water 
outputting (which indicates the tank is filled with water), please close water outlet, check if there is 
water leakage at each joint and plug the power.
1.

Startup
After power connection, fully display for 1 second and buzzer sounds for indication, then enter 
into shutdown state (clock displayed only). For the first time power-on, the clock displays the 
system default time 00:00 (hour figure and minute figure constantly light and “:” in the middle 
flashes).  In  shutdown  state,  press 

   

  key  to  enter  into  working  state.  For  the  first  time  of 

startup, the system displays initial state, wherein the initial state defaulted by the system is: set 
temperature shows 75

æ actual temperature shows the ambient temperature of the sensor; 

power shows 3.0Kw.
For example: actual temperature is 35

æ

æ; time shows 00:00. (As shown in Figure 5)

Note:  in  heating  state,  Heating  Temp  indicator  flashes;  in  holding  state,  Heating  Temp 
indicator lights constantly.

(Figure 5)

SPEED

SET

TIMER

:

Current Temp.

Heating Temp.

Normal Fast Turbo

SPEED

SET

TIMER

Kw

.

On  Off

:

Curre nt Temp.

Heati ng Temp.

Norm al Fast Turb o

SPEED

SET

TIM ER

Kw

.

On  Off

:

SPEED

SET

TIMER

Current Temp.

Heating Temp.

                      Turbo

SPEED

SET

TIMER

Kw

.

On  Off

:

A

fte

r p

o

w

e

r c

o

n

n

e

ct

io

n

, d

is

p

la

sh

o

w

e

ve

ry

th

in

g

 fo

r 1

s.

1.

Actual temperature

2.

Set temperature

3.

Power

4.

Current time

5.

Clock, temperature figure increase key

6.

Power selection key

7.

Time setting key

8.

On/Off key

9.

Preset bath, preset shutdown setting 
key

10. Clock, temperature figure decrease key
11

.

Preset bath, preset shutdown (On: 
preset bath; Off: preset shutdown)

 

After 1s, 

enter into 
shutdown 
state.
(Note: for 
the next 
power 
connectio
n, the 
clock will 
show the 
current 
base time 
of the PC 
panel set 
before 
the 
power 
failure the 
last time.)

In

 s

h

u

td

o

w

n

 s

ta

te

, p

re

ss

 

  

 k

e

y

 to

 s

ta

rt 

u

p

 th

e

 h

e

a

te

fo

r r

u

n

n

in

g

, o

th

e

r k

e

ys

 d

o

 n

o

t w

o

rk

 a

t th

is

 tim

e

.

Normal Fast 

Turbo

Summary of Contents for ES15V-P1

Page 1: ...Little Sea ox Haier Household Electric Water Heater Please read this manual before usage Retain it for future reference 0040502335 V ES15V P1 ES25V P1 ES35V P1 ...

Page 2: ...ipeline In this case no smoke or fire is permitted near the open valve Carefully check and confirm all parts are in good condition This mark is the designation of Pre safe Expert by Haier Water Heater Company which indicates use of the company s patented technology inside the product It ensures you a safe bath while continuously monitoring whether your house ground wire is live or not If this mark...

Page 3: ... apologize for the inconvenience occurred therefrom 12 Usage 4 Holding temperature preset Without presetting of bath state when the temperature is set to be less than 55 reheating will be started when the temperature is decreased by 5 if the temperature is set to be 55 75 including 55 and 75 reheating will be started when the temperature is decreased by 10 5 Shutdown After bath press key if you wa...

Page 4: ...ght press SET key to preset bath and shutdown time When presetting bath time On indicator flashes when presetting shutdown time Off indicator flashes After setting if no operation is made within 2 minutes the system will enter into power saving mode and only On Off and clock on display light When up to the preset heating time calculated by the system the heater will automatically heat and the Heat...

Page 5: ...10 Current Temp Current Temp Current Temp Current Temp Heating Temp Heating Temp Heating Temp Heating Temp Normal Turbo Fast Normal Turbo Fast Normal Fast Turbo Normal Fast Turbo SPEED SPEED SPEED SPEED SET SET SET SET TIMER TIMER TIMER TIMER Kw Kw Kw Kw On Off On Off On Off On Off Current Temp Heating Temp Normal Fast Turbo SPEED SET TIMER Kw On Off Current Temp Heating Temp Normal Turbo Fast SPE...

Page 6: ...interface Heating Temp indicator flashes when entry into heating state from power saving mode The heater is provided with auto heating function The system automatically calculates the time required for heating to set temperature according to the heating power set by the customer and then determines the starting time for heating Before water using time set automatically heat to set temperature and ...

Page 7: ...orresponding wall holes Lift the water heater Make wall rack correspond to the hooks Hang the ring of extended connection line onto a hook and hand the wall rack see Figure 2 Install accessories such as safety valve as shown in Figure 3 Use sealing compound to prevent water leakage To facilitate installation and removal it is suggested a G1 2 movable nut is fitted at appropriate locations on inlet...

Page 8: ...sphere Check safety valve once a month as follows move the small handle of safety valve if there is water flowing out safety valve is normal if there is no water flow please contact local after sales service station The pressure relief hole is to be operated regularly to remove lime deposits and to verify that it is not blocked Installation Attentions in installation Installation Attentionsininsta...

Reviews: