1. SAFETY 

PRECAUTIONS 

1.  The design of this product contains special hardware, many 

circuits and components especially for safety purposes. For 
continued protection, no changes should be made to the 
original design unless authorized in writing by the 
manufacturer. Replacement parts must be identical to those 
used in the original circuits. Service should be performed by 
qualified personnel only. 

 
2.  Alterations of the design or circuitry of the products should 

not be made. Any design alterations or additions will void the 
manufacturer’s warranty and will further relieve the 
manufacturer of responsibility for personal injury or property 
damage resulting therefrom. 

 
3.  Many electrical and mechanical parts in the products have 

special safety-related characteristics. These characteristics 
are often not evident from visual inspection nor can the 
protection afforded by them necessarily be obtained by using 
replacement components rated for higher voltage, wattage, 
etc. Replacement parts which have these special safety 
characteristics are identified in the parts list of Service 
manual. Electrical components having such features are 
identified by shading on the schematics and by ( 

  ) on 

the parts list in Service manual. The use of a substitute 
replacement which does not have the same safety 
characteristics as the recommended replacement part 
shown in the parts list of Service manual may cause shock, 
fire, or other hazards 

 
4. 

Don’t short between the LIVE side ground and 
ISOLATED (NEUTRAL) side ground or EARTH side 
ground when repairing

. Some model’s power circuit is 

partly different in the GND. The difference of the GND is 
shown by the LIVE: (   ) side GND, ISOLATED  
(NEUTRAL): (      ) side GND and EARTH: (        ) side GND. 
Don’t short between the LIVE side GND and ISOLATED 
(NEUTRAL) side GND or EARTH side GND and never 
measure with a measuring apparatus (oscilloscope etc.) the 
LIVE side GND and ISOLATED (NEUTRAL) side GND or 
EARTH side GND at the same time. If above note will not be 
kept, a fuse or any parts will be broken. 

 
5.  If any repair has been made to the chassis, it is 

recommended that the B1 setting should be checked or 
adjusted (See ADJUSTMENT OF B1 POWER SUPPLY). 

 
6. 

The high voltage applied to the picture tube must conform to 
that specified in Service manual. Excessive high voltage can 
cause an increase in X-Ray emission, arcing and possible 
component damage, therefore operation under excessive 
high voltage conditions should be kept to a minimum, or 
should be prevented. If severe arcing occurs, remove the AC 
power immediately and determine the cause by visual 
inspection (incorrect installation, cracked or melted high 
voltage harness, poor soldering, etc.). To maintain the proper 
minimum level of soft X-Ray emission, components in the 
high voltage circuitry including the picture tube must be the 
exact replacements or alternatives approved by the 
manufacturer of the complete product. 

 
7.  Do not check high voltage by drawing an arc. Use a high 

voltage meter or a high voltage probe with a VTVM. 
Discharge the picture tube before attempting meter 
connection, by connecting a clip lead to the ground frame 
and connecting the other end of the lead through a 10k

 2W 

resistor to the anode button. 

 
8.  When service is required, observe the original lead dress. 

Extra precaution should be given to assure correct lead 
dress in the high voltage circuit area. Where a short circuit 
has occurred, those components that indicate evidence of 
overheating should be replaced. Always use the 
manufacturer’s replacement components. 

9. Isolation 

Check 

(Safety for Electrical Shock Hazard) 
After re-assembling the product, always perform an isolation 
check on the exposed metal parts of the cabinet (antenna 
terminals, video/audio input and output terminals, Control 
knobs, metal cabinet, screw heads, earphone jack, control 
shafts, etc.) to be sure the product is safe to operate without 
danger of electrical shock. 

10.  The surface of the TV screen is coated with a thin film which 

can easily be damaged. Be very careful with it when handle 
the TV.

 

Should the TV screen become soiled, wipe it with a 

soft dry cloth. Never rub it forcefully. Never use any cleaner 
or detergent on it.

 

 
(1) Dielectric 

Strength 

Test 

The isolation between the AC primary circuit and all metal 
parts exposed to the user, particularly any exposed metal 
part having a return path to the chassis should withstand a 
voltage of 3000V AC (r.m.s.) for a period of one second. 
(…Withstand a voltage of 1100V AC (r.m.s.) to an appliance 
rated up to 120V, and 3000V AC (r.m.s.) to an appliance 
rated 200V or more, for a period of one second.) 
This method of test requires test equipment not generally 
found in the service trade. 

(2)  Leakage Current Check 

Plug the AC line cord directly into the AC outlet (do not use 
line isolation transformers during this check). Using a 
“Leakage Current Tester”, measure the leakage current from 
each exposed metal part of the cabinet, particularly any 
exposed metal part having a return path to the chassis, to a 
known good earth ground (water pipe, etc.). Any leakage 
current must not exceed 0.5mA AC (r.m.s.). 
However, in tropical area, this must not exceed 0.2mA AC 
(r.m.s.). 

Alternate Check Method 

Plug the AC line cord directly into the AC outlet ( do not use 
a line isolation transformer during this check.). Use an AC 
voltmeter having 1000 ohms per volt or more sensitivity in 
the following manner. Connect a 1500

 10W resistor 

paralleled by a 0.15µF AC-type capacitor between an 
exposed metal part and a known good earth ground (water 
pipe, etc.). Measure the AC voltage across the resistor with 
the AC voltmeter. Move the resistor connection to each 
exposed metal part, particularly any exposed metal part 
having a return path to the chassis, and measure the AC 
voltage across the resistor. Now, reverse the plug in the AC 
outlet and repeat each measurement. Any voltage measured 
must not exceed 0.75V AC (r.m.s.). This corresponds to 
0.5mA AC (r.m.s.). 
However, in tropical area, this must not exceed 0.3V AC 
(r.m.s.). 
This corresponds to 0.2mA AC (r.m.s.) 

 

 

 

Summary of Contents for DTA-1518

Page 1: ...TV DVD 1533FL FEATURES z DVD TV 15 COMBO z AUTO TUNE 250 CHANNES z DVD VCD SVCD CD CD R CD RW JPEG MP3 COMPATIBLE z FORMATO DE VIDEO 4 3PS 4 3LB z DOLBY AC 3 DECODE z PANATAL LOCK CAUTION READ THIS MA...

Page 2: ...3 2 TV block diagram 4 3 Replacement of memory IC 5 4 Service adjustment 5 5 ICs functional description 8 6 Test point waveform 10 7 All ICs voltages 10 8 Purity convergence adjustment 12 9 DVD maint...

Page 3: ...not check high voltage by drawing an arc Use a high voltage meter or a high voltage probe with a VTVM Discharge the picture tube before attempting meter connection by connecting a clip lead to the gro...

Page 4: ...4 2 Block diagram TDA9351PS N2 series with mono intercarrier sound demodulator...

Page 5: ...ess AV TV key to exit factory mode Focus adjustment 1 Receive a crosshatch signal 2 While watching the screen adjust the FOCUS VR on the FBT to make the vertical and horizontal lines as fine and sharp...

Page 6: ...tical Offset 2 HOF 36 A OSDHorizontalOffset 2 ZOOM 32 A 16 9 scene extent 2 VOL0 6 A MIN volume 2 VOL16 16 A SET VOLUME 16 2 VOL32 32 A SET VOLUME 32 2 V63 63 A MAX volume 3 WPR 31 A White Point R WPG...

Page 7: ...IF 100 A Brightness 100 SHPF 100 A Listen Sharpness RGBL 8 A boot strap wait for time ONMT 1F A boot strap black time 6 LCOL 3 A factory standard color SIZE 3 A factory standard size ICON 5 A Soft CON...

Page 8: ...Bit 4 CHANNEL_IN_SCART 1 Enable 1 EA Bit 5 IDENT_SENSITIVE 1 Enable 0 EA Bit 6 HALFTONE 1 Enable 0 EA Bit 7 ZOOM 1 Enable 0 1 Enable ZOOM EA 5 OP5 Bit Function Description Preset Remark Bit 0 SOUND_BG...

Page 9: ...EA Bit 3 ITALY 1 Enable 1 EA Bit 4 RUSSIA 1 Enable 1 EA Bit 5 SPANISH 1 Enable 1 EA Bit 6 PORTUGUESE 1 Enable 1 EA Bit 7 DUTCH 1 Enable 1 EA Note Don t adjust any OPTION items please inform the engin...

Page 10: ...0 internal CVBS input GND 41 ground for TV processor CVBS Y 42 CVBS SVHS Y input C IN 43 SVHS C input AUDIO 44 Audio output INSW2 45 YUV insertion input S R 46 R input V R Y input PR input S G 47 G in...

Page 11: ...gnal 4 Vertical deflection booster TDA4863AJ Symbol PIN Function Symbol PIN Function VP1 1 positive supply voltage 1 V OUT 5 vertical output VP3 2 flyback generator output INN 6 inverted input of diff...

Page 12: ...V 0 5 0 3 0 1 7 2 4 3 4 8 3 9 0 3 3 0 3 6 1 4 2 5 2 5 2 5 PIN 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 V 1 9 5 0 2 4 2 4 2 4 3 1 0 3 2 0 1 8 1 7 0 3 2 5 1 3 3 5 TDA4863AJ PIN 1 2 3 4 5 6 7 13...

Page 13: ...he screen Fig 3 8 Move the deflection yoke forward and fix the position of the deflection yoke so that the whole screen will become green 9 Insert the wedge to the top side of the deflection yoke so t...

Page 14: ...convergence DYNAMIC CONVERGENCE ADJUSTMENT 1 Move the deflection yoke up and down and overlap lines in the periphery Fig 2 2 Move the deflection yoke left to right and overlap the lines in the periph...

Page 15: ...nding pins of MT1389D to see if there is any short circuit break or faulty soldering 4 System in normal operation but the audio has no sound 1 Because the AUDIO DAC is built in MTK1389D IC you need to...

Page 16: ...PDF pdfFactory Pro www fineprint com cn...

Page 17: ......

Page 18: ...16 Sincere Forever Haier Group Haier Industrial Park No 1 Haier Road 266101 Qingdao China http www haier com...

Reviews: