8

Bucket Full Indicator

When the indicator light comes on, automatic flow

control stops the unit.

Turn the unit off by pressing the POWER key.

Check to see if the bucket is full. If so, empty it.

If bucket is not full and indicator light is on, the

bucket is not in the proper position. Remove and

reinstall it.

 

Hr

CURRENT

HUMIDITY
SET

HUMIDITY

3

4

5

6

7

8

9

10

Check Filter Indicator

The "check filter" indicator will flash when the  

filter needs to be cleaned.  Remove the filter, 

wash it, and put it back in.  Press "Filter Reset."  

The "check filter" indicator will turn off.

Note: Make sure the filter is dry before replacing. 

6

Smart Dry

This setting compares the set humidity level with

the actual humidity level and adjusts the fan 

speed automatically.

7

Signal

The bucket full audible signal can be turned on 

and off by pressing the SIGNAL button.  The 

default setting is set in the ON position.  When 

the bucket is full, the red BUCKET FULL indicator 

light will blink and the alarm will sound 5 times 

every 15 minutes. 

To turn off the audible signal feature, press the 

SIGNAL button once, and the LED display will 

show “OF” for 2 seconds.  In this setting, when 

the bucket is full, the BUCKET FULL indicator light

will blink, but the audible alarm will not sound.

To reactivate the audible signal, press the 

SIGNAL button and the LED display to the left 

will show “ON” for 2 seconds.

5

Power

2

10

Current Humidity/Setting Humidity Display

Displays the current humidity level and adjusts the

humidity to a desired level.

Setting Humidity Range: 40%RH~70%RH

Display Humidity Range: 

(LO)30%RH~(HI)90%RH

9

Current Temp/Timer Set Display

When the dehumidifier is running

,

it displays the 

current temperature.Press the timer 

key to 

program

the dehumidifier to turn on or off automatically at a

pre-deter mined time.

Summary of Contents for DE45EM

Page 1: ...2014 DE45EM DE45EM T DE45EM TC DE45EM E DE65EM DE65EM T DE65EM TC DE65EM E AC1011S004V0 ...

Page 2: ...8 0 1 3 ...

Page 3: ...M ...

Page 4: ...ints 180 150 57 56 11 15 R410A 7 4Oz 4 2 480 690 21 13 3 8 10 5 8 22 1 2 14 3 4 12 16 8 18 6 17 7 18 6 910 740 14 16 1 2 25 3 16 12 15 23 1 2 6 2 R410A 8 1Oz 57 56 220 200 65 Prints Unit Dimensions 1 85 1 85 ...

Page 5: ...3 ...

Page 6: ...NO other extension cord is permitted ...

Page 7: ...e to the direct drain opening Fig 2 3 Position the dehumidifier as close as you can to the floor drain 5 When the direct drain feature is not being used remove the drain hose from the direct drain opening and plug it with the rubber cap provided 4 Position the opening end of the drain hose directly over the floor drain and start the unit ...

Page 8: ......

Page 9: ...urned on and off by pressing the SIGNAL button The default setting is set in the ON position When the bucket is full the red BUCKET FULL indicator light will blink and the alarm will sound 5 times every 15 minutes To turn off the audible signal feature press the SIGNAL button once and the LED display will show OF for 2 seconds In this setting when the bucket is full the BUCKET FULL indicator light...

Page 10: ...8 ...

Page 11: ...9 ...

Page 12: ...0 dehumidify evaporator condenser ...

Page 13: ... PTD4 T1CH0 28 PTA5 29 RST 30 PTA7 31 ADC12 32 IC1 MC68HC908JL8CSPE SDIP32 5V C7 0 1uF 5V 5V P I P E H U M I D I T Y R O O M C O M P L O W H I V A L V E F U L L V 5 D N G 1 2 CN23 TJC8 2 DATA OSC1 IRQ GND 5V SMART HI LOW T_ON T_OFF FULL FLTER SIGNAL SPEED TIMER UP DOWN FLTERRESET POWER Temp Timer C30 0 1uF A0 1 A1 2 A2 3 VSS 4 SDA 5 SCL 6 TEST 7 VCC 8 IC5 AT24C02B DIP8 R1 100Ω R7 1K R38 4 7K R26 1...

Page 14: ... 2 IC3 ULN2003 SOP16 CN5 D187 8A CN6 D187 8A 1 2 3 4 5 6 7 8 9 0 1 CON1 480mm 10 B10B PH 5V R C RC1 300V 120Ω 103 R C RC2 300V 120Ω 103 1 CN9 D250 10A 1 CN10 D187 8A 1 1 CN8 D187 8A 1 CN7 D187 8A P I P E H U M I D I T Y R O O M C O M P L O W H I V A L V E F U L L V 5 GND 1 2 3 CN3 4 00 m m 3 B 3B XH HUMIDITY 1 2 3 4 5 6 7 8 9 10 C13 0 1uF C16 0 1uF C15 0 1uF C14 0 1uF 12V E5 220uF 25V C9 0 1uF C20...

Page 15: ... BR BROWN B BLACK Y YELLOW W WHITE R RED WIRING DIAGRAM R O O M S E N S O R P I P ET E M P S E N S O R W CN2 CN4 NO C S W I T C H F L O A T W BL BL B BL BL R 0R CN8 CN7 CN11 CON1 CN1 T E M P HI LOW 3 CN6 CN5 DCF CN10 N B BR G Y G CONTROL BOARD 1 1 2 2 BECAUSE OF DIFFERENT MODELS THE PART MAY NOT BE USED 0010512580 NC HERM FAN C W M M M Y 2 CN3 S E N S O R H U M I D I T Y B 13 ...

Page 16: ...ic Air Conditioner Sincere Forever Haier Group Haier Industrial Park No 1 Haier Road Edited by GuanLi DingCheng 266101 Qingdao China Signed by WangRuoFeng Tel 86 532 88936935 Approved by ZhangPeng Http www haier com ...

Reviews: