16
16
SERVICE MANUAL
Moisture forms on
outside of cabinet
Not unusual during periods of
high humidity
Wipe surface
Interior light does
not work (on some
models)
No power at outlet.
Replace fuse or reset the breaker
Freezer is unplugged.
Push the plug completely into the outlet.
Light bulb burned out.
●
Replace bulb.
Door/lid wont fully
●
close by itself
Package holding door/lid
open.
Store only corrects quantity of food.
Slow starting time
after being off
Built-in overload product.
Store only corrects quantity of food.
Excessive frost
build-up
Door/lid left open.
Check to see if package is holding door/lid
open.
Too frequent or too long
door/lid openings.
Reduce the time of opening the door/lid
Not unusual during periods of
high humidity
Put the freezer to suitable place
8-2. Abnormal phenomena
●
8-2-1. Compressor doesn’t start
Com pressor
doesn
’
t start
Whether lighting
and display system is
normal
W hether the
grade of thermostat is
on 0
W hether
●
the
resistance of com pressor is
●
infinite or 0
W hether the
starting current is
about 5A
抯
W hether PT C starter
resistance between running jack
and starting jack is 16-50 O
Measure whether
two ends of heat protector
is through
Whether the finger
of multimeter swing to 0 quickly
and then swing back slowly
when measuring two
Y
Trouble of lighting and display system
Adjust the grade according to fact
Compressor is open circuit or short
circuit
Inner trouble of compressor
If it is infinite or 0, then the starter is
out of work.
Heat protector is out of work
Capacitance is out of work
C
h
a
n
g
e
fo
r a
n
e
w
c
o
m
p
re
s
s
o
r
Y
N
N
N
Y
Y
N
Y
Y
Y
N
N
N
Summary of Contents for CHM9BPL3
Page 18: ...17 17 SERVICE MANUAL 8 2 2 Poor cooling ...