18
STEP 2 - CONNECT TO A GAS SUPPLY LINE
(GAS DRYER ONLY)
NOTE:
Do not connect the dryer to an LP gas line without
Þ
rst converting the
dryer with a conversion kit. An LP conversion kit must be installed by a quali
Þ
ed
technician.
NOTE:
Apply a pipe-joint compound that that is resistant to the action of LP gas to
all males threads. Do not use plumber’s tape.
1.
Turn the gas supply o
by moving the shuto
valve to the closed position.
Closed Valve
Open Valve
A
B
2.
Disconnect and discard old
ß
exible gas connector. Replace with a new
CSA(AGA) approved
ß
exible gas connector.
3.
Remove the shipping cap from the gas inlet pipe at the rear of the dryer.
4.
Connect a
!
" NPT elbow to the gas inlet pipe on the dryer. Then connect a
ß
are
adapter to the elbow.
IMPORTANT:
Use a pipe wrench to keep the dryer gas inlet pipe from twisting.
Gas Inlet Pipe on
the Dryer
!
" NPT Elbow
!
" NPT Flare Adapter
A
B
C
5.
Connect the dryer to the gas supply line with a
ß
exible gas connector.
Flexible Gas Connector
A
6.
Tighten the
ß
exible gas connector using two adjustable wrenches.