Emergency Operation:

•  Use this operation only when the remote control is defec

-

tive or lost. 

•  When the emergency operation switch is pressed, the unit 

beeps once, which indicates the start of this operation. 

•  When the power switch is turned on for the first time and 

emergency operation starts, the unit will run automatically 
in the following modes: 

•  During emergency operation, it is not possible to change 

the settings of temperature and fan speed. It is also not 
possible to operate in timer or dry modes.

Beep

emergency

operation switch

    Room

temperature

Designated

temperature

Timer

mode

Fan

speed

Operation

mode

  Above 73

o

F

  Below 73

o

F

 

73

o

F

 79

o

F

No

AUTO

AUTO

COOL

HEAT

No

1. 

Remove the battery cover

2. 

Insert 2 AAA batteries as 

illustrated noting battery polarity

3. 

Reinstall the battery cover 

NOTE:

• 

The distance from the remote 
control to the receiver should 

be less than 23 feet with no 

obstructions.

•  If the remote control display is weak or the operating 

distance has diminished, the batteries may need to be 

replaced.

• 

Remote control malfunctions can sometimes be corrected 

by removing the batteries from the remote for a few min

-

utes and then reinstalling them.

• 

Remove the batteries from the remote control if the unit 

will not be in use for an extended period of time. If any seg

-

ments of the display remain active after battery removal, 

press the reset button.  

Do not block the air inlet 
or outlet

Close doors and windows 

during operation

Wipe the air conditioner using a soft and 

dry cloth. For serious stains, use a neutral 
detergent diluted with water. Wring the water 
out of the cloth before wiping down the unit. 
Then wipe off the detergent completely.

During cooling operation

prevent direct sunlight   

   with curtains or blinds

1. Open the inlet grille by pulling 

it upward

2. Remove the filter. 

Gently push up on the filter’s center 

tab until it is released from the 

stopper, and remove the filter 

downward.

3. Clean the filter. 

Use a vacuum cleaner to remove 

dust, or wash the filter with water. 

After washing, dry the filter 

completely.

4. Attach the filter

Attach the filter so that the “FRONT” 

label is facing the front. Make sure 

that the filter is securely attached 

behind the holding tabs. If the filter is 

not attached correctly the unit may 

not achieve maximum efficiency.

5. Close the inlet grille.

Once every

two months

EMERGENCY OPERATION & MAINTENANCE

Inserting the Batteries

Emergency Operation

Optimizing Performance

Cleaning the Air Filter

15

 

HEALTH Button

 

Feature not available on this series.

16

 

Confirm/Cancel Button

 

Function: Setting and canceling timer and other functions.

17

 

LOCK Button

 

Used to lock buttons and LCD display

18

 

LIGHT Button

 

Turns indoor unit display on and off

19

 

RESET Button

 

If the remote control is not functioning properly, use a pen 
point or similar object to depress this button to reset the 

remote.

Summary of Contents for AW07LC2VHA

Page 1: ...as a burnt smell are found immediately power off the main switch and contact a licensed contractor Do not obstruct or cover the ventilation grille on the air conditioner Do not put fingers or any other things into the inlet outlet or swing louver Do not allow children to play with the air conditioner Children should never be allowed to sit on the outdoor unit Please read this manual before using t...

Page 2: ...re The will be displayed during COOL mode 4 HEAT Button In HEAT mode warm air will blow out after a short period of the time due to cold air prevention function When FAN is set to AUTO the air conditioner automatically adjusts the fan speed according to room temperature The will be displayed during HEAT mode 5 DRY Button DRY mode is used to reduce humidity In DRY mode when room temperature becomes...

Page 3: ... Once the desired length of time is selected for the unit to turn on press the CONFIRM CANCEL to confirm this setting The remote control display changes as follows BLANK TIMER ON TIMER OFF TIMER ON OFF TIMER OFF ON 0 5h 0 5h 0 5h 0 5h Cancel TIMER ON setting With a TIMER ON set press the CONFIRM CANEL button once to cancel the TIMER ON Turning the unit ON with the TIMER from it being OFF will look...

Page 4: ...RA FUNCTION Button Function A Refresh air Feature not available on this series B A B Yard This will allow you to control two seperate units with a single remote control Note this feature would be setup at the time of installation by the contractor C Fan Mode Is indicated by the icon Only the fan will operate in this mode See section 8 FAN Button for changing the fan settings D Intelligent upward a...

Page 5: ...of the display remain active after battery removal press the reset button Do not block the air inlet or outlet Close doors and windows during operation Wipe the air conditioner using a soft and dry cloth For serious stains use a neutral detergent diluted with water Wring the water out of the cloth before wiping down the unit Then wipe off the detergent completely During cooling operation prevent d...

Page 6: ... If the airflow creating a loud noise during unit operation the air filter may be too dirty The system circulates smells from the indoor air such as the smell of furniture paint and or cigarettes During COOL or DRY operation indoor unit may blow out mist This is due to the sudden cooling of the indoor air In DRY mode when the room temperature becomes lower than the set temperature by 2 F the unit ...

Page 7: ...nstallation 2 Damages in shipping 3 Defects other than manufacturing 4 Damages from misuse abuse accident alteration lack of proper care and maintenance or incorrect electrical voltage or current 5 Damages from other than household use 6 Damages from services performed by other than a licencensed HVAC technician THIS LIMITED WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCL...

Page 8: ...Haier America Wayne NJ 07470 2015 Haier America Trading LLC Indoor Model AW09ES2VHA AW12ES2VHA AW18ES2VHA AW24ES2VHA AW07LC2VHA AW09LC2VHA AW12LC2VHA AW18LC2VHA Issued Date January 2015 www Haier com ...

Reviews: