Functions and control
18
Domestic air conditioner
state). TC=indoor coil temp.
The indoor heat exchanger sensor tests the temperature of the indoor heat exchanger. If the
temperature is higher than 63
℃
, decrease the rotate speed of the compressor and do the high
temperature-preventing protection of the indoor heat exchanger; if the temperature of the indoor heat
exchanger is lower than 4
●
5
℃
, recover to the normal control.
(09K12K)
TC(
℃
)
The compressor stops
Fgh_t1 63
℃
/63
℃
Fgh_t1
-
2
Fgh_t2
-
2
N Decreasing the frequency rapidly Fgh_t2 60
℃
/59
℃
P Decreasing the frequency slowly Fgh_t3 57
℃
/56
℃
Fgh_t3
-
2
Fgh_t4—2
Q Prohibiting increasing the frequency Fgh_t4 52
℃
/53
℃
R Increasing slowly
Fgh_t5 40
℃
/40
℃
Fgh_t5—2
Normal
N
:
Decreasing at the speed of 1HZ/1 second
●
P
:
Decreasing at the speed of 1Hz/10 seconds
●
Q
:
Continue to keep the last-time instruction cycle
R
:
Increasing at the speed of 1Hz/10seconds
Remarks: the outdoor unit
7.1.5.3 The control of preventing the over current of the compressor:
●
During the starting process of the compressor, if the current of the compressor is greater than 12.5A
for 3 seconds, stop the compressor and alarm, after 3 minutes, start it again, if such state appears 3 times
in 20 minutes, stop the compressor and alarm, and confirm the malfunction. Then continue to run it only
after the power is off.
●
During the starting process of the compressor, if the AC current is greater than 9A, the frequency of
the compressor decreases at the speed of 1HZ/second.
●
During the starting process of the compressor, if the AC current is greater than 8A, the frequency of
the compressor decreases at the speed of 0.1HZ/second.
●
During the starting process of the compressor, if the AC current is greater than 7.5A, the frequency of
the compressor increases at the prohibited speed.
●
During the starting process of the compressor, if the AC current is greater than 6.5A, the frequency of
the compressor increases at the speed of no faster than 0.1HZ/second.
7.1.5.4 The protection function of AC current:
During the starting process of the compressor, if the AC current is greater than 12.5A for 3 seconds,
stop the compressor and alarm, after 3 minutes, start it again, if such state appears 3 times in 20 minutes,
●
stop the compressor and alarm, and confirm the malfunction. Then continue to run it only after the the
power is off.
During the starting process of
●
the compressor, if the AC current is greater than 9A, the frequency of the
compressor decreases at the speed of 1HZ/second.
During the starting process of the compressor, if the AC current is greater than 8A, the frequency of the
compressor decreases at the speed of 0.1HZ/second.
During the starting process of the compressor, if the AC current is greater than 7.5A, the frequency of
Summary of Contents for AS25THMHRA-C
Page 2: ......
Page 41: ...Piping diagrams Domestic air conditioner 5 Piping diagrams 10...
Page 56: ...Dimensional drawings 24 Domestic air conditioner 8 Dimensional drawings 9 Center of gravity...
Page 73: ...Circuit diagrams 43 Domestic air conditioner 11 Circuit Diagrams...
Page 74: ...Circuit diagrams 44 Domestic air conditioner...
Page 79: ...three 6 Removal Procedure 4 Domestic Air Conditioner Remove the casing 1 2 3...
Page 83: ...Removal Procedure 8 Domestic Air Conditioner motor cover motor cover...
Page 84: ...Removal Procedure 9 Domestic Air Conditioner...
Page 96: ...Pinping diagrams Domestic air conditioner 4 Piping diagrams 9...
Page 97: ...Operation range 10 Domestic air conditioner 5 Operation range 10 0 21 27 35 20 40 60 43 20 40...
Page 99: ...Functions and control 13 Domestic air conditioner Wiring diagrams OUTDOOR UNIT...
Page 122: ...Service diagnosis 37 Domestic air conditioner...
Page 141: ...57 Do C omestic air ircuit Diagra conditioner ams r...
Page 142: ......
Page 144: ...Removal Procedure 1 Removal of Outdoor panel RPHVWLF LU RQGLWLR...
Page 145: ...Removal Procedure 2 Domestic Air Condition...
Page 146: ...4 Removal Procedure 3 Domestic Air Condition...
Page 147: ...Removal Procedure 2 Removal of Electrical Box RPHVWLF LU RQGLWLR...
Page 148: ...Removal Procedure 3 Removal of Fan and Fan Motor RPHVWLF LU RQGLWLR...
Page 149: ...Removal Procedure 4 Removal of fan motor brcked and partition RPHVWLF LU RQGLWLR...
Page 150: ...Removal Procedure 7 Domestic Air Condition...
Page 151: ...Removal Procedure 5 Removal of compressor and heat exchanger RPHVWLF LU RQGLWLR...
Page 152: ...Removal Procedure 9 Domestic Air Condition...
Page 165: ...Piping diagrams Domestic air conditioner 5 Piping diagrams 10...
Page 180: ...Dimensional drawings 24 Domestic air conditioner 8 Dimensional drawings 9 Center of gravity...
Page 197: ...Circuit diagrams 43 Domestic air conditioner 11 Circuit Diagrams...
Page 198: ...Circuit diagrams 44 Domestic air conditioner...
Page 203: ...three 6 Removal Procedure 4 Domestic Air Conditioner Remove the casing 1 2 3...
Page 206: ...2 7 Domestic Air Conditioner Removal Procedure Lift up the exchanger and remove it 1...
Page 207: ...Removal Procedure 8 Domestic Air Conditioner motor cover motor cover...
Page 208: ...Removal Procedure 9 Domestic Air Conditioner...
Page 220: ...Piping diagrams Domestic air conditioner 4 Piping diagrams 9...
Page 221: ...Operation range 10 Domestic air conditioner 5 Operation range 10 0 21 27 35 20 40 60 43 20 40...
Page 223: ...Functions and control 13 Domestic air conditioner Wiring diagrams OUTDOOR UNIT...
Page 246: ...Service diagnosis 37 Domestic air conditioner...
Page 265: ...57 Do C omestic air ircuit Diagra conditioner ams r...
Page 266: ......
Page 268: ...Removal Procedure 1 Removal of Outdoor panel RPHVWLF LU RQGLWLR...
Page 269: ...Removal Procedure 2 Domestic Air Condition...
Page 270: ...4 Removal Procedure 3 Domestic Air Condition...
Page 271: ...Removal Procedure 2 Removal of Electrical Box RPHVWLF LU RQGLWLR...
Page 272: ...Removal Procedure 3 Removal of Fan and Fan Motor RPHVWLF LU RQGLWLR...
Page 273: ...Removal Procedure 4 Removal of fan motor brcked and partition RPHVWLF LU RQGLWLR...
Page 274: ...Removal Procedure 7 Domestic Air Condition...
Page 275: ...Removal Procedure 5 Removal of compressor and heat exchanger RPHVWLF LU RQGLWLR...
Page 276: ...Removal Procedure 9 Domestic Air Condition...
Page 289: ...Piping diagrams Domestic air conditioner 5 Piping diagrams 10 CAPILLARY CAPILLARY...
Page 291: ...Printed circuit board connector wiring diagram 12 Domestic air conditioner PCB 1...
Page 318: ...Service diagnosis 40 Domestic air conditioner...
Page 321: ...11 Circ cuit Diag grams 43 Do C omestic air ircuit Diagra conditioner ams r...
Page 322: ...44 Do C omestic air ircuit Diagra conditioner ams r...
Page 323: ......
Page 351: ...Piping diagrams 9 Domestic air conditioner 4 Piping diagrams...
Page 352: ...Operation range 10 Domestic air conditioner 5 Operation range 10 0 21 27 35 20 40 60 43 20 40...
Page 355: ...Wiring diagrams Wiring diagrams 13 Domestic air conditioner...
Page 397: ......
Page 398: ......
Page 420: ...Piping diagrams Domestic air conditioner 5 Piping diagrams 10 EEV EEV...
Page 422: ...Printed circuit board connector wiring diagram 12 Domestic air conditioner PCB 1...
Page 449: ...Service diagnosis 40 Domestic air conditioner...
Page 452: ...11 Circ cuit Diag grams 43 Do C omestic air ircuit Diagra conditioner ams r...
Page 453: ...44 Do C omestic air ircuit Diagra conditioner ams r...
Page 481: ...Pinping diagrams Domestic air conditioner 4 Piping diagrams 9 EEV EEV...
Page 482: ...Operation range 10 Domestic air conditioner 5 Operation range 10 0 21 27 35 20 40 60 43 20 40...
Page 500: ...Dimensional drawing 28 Domestic air conditioner 8 Dimensional drawings 9 Center of gravity...
Page 507: ...Service diagnosis 36 Domestic air conditioner...
Page 529: ......