Operation
Air Flow Direction Adjustment
Press FAN button. For each press, fan speed
follows:
Remote controller:
Press
button
Every time the button is pressed, temp.setting
increase 1
o
C,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease 1
o
C,if kept depressed, it will
decrease rapidly
Select a desired temperature.
4.Fan speed selection
3.Select temp.setting
Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner
automatically adjusts the fan speed according to room
temperature.
1. Unit start
Press ON/OFF on the remote controller, unit starts.
Base Operation
Remote controller
When restart after remote turning off, the remote controller
Move the vertical blade by a knob on airconditioner
to adjust left and right direction referring to Fig.
4.Left and right air flow adjustment(manual)
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur
It is advisable not to keep horizontal flap at downward
position for a long time in COOLor DRY
otherwise, condensate water might occur.
Emergency operation and test operation
adjusted to left or at air outlet if all vertical louvers are right.
mode ,
controller will automatically memorize the previous set swing position.
Note:
changes as
Operation
Mode
Remote
Controller
Note
In DRY mode , when room temperature becomes lower
than temp.2
o
C, unit will run intermittently at LOW
speed regardless of FAN setting.
Under the mode of auto operation, air conditioner will
automatically select Cool or Heat operation according to
room temperature. When FAN is set to AUTO the air
conditioner automatically adjusts the fan speed according
to room temperature.
In FAN operation mode , the unit will not operate in COOL or
HEAT mode but only in FAN mode, AUTO is not available in
FAN mode. And temp. setting is disabled. In FAN mode,
sleep operation is not available.
Emergency Operation:
Use this operation only when the remote controller is defective
or lost, and with function of emergency running, air conditoner
can run automatically for a while.
When the emergency operation switch is pressed, the " Pi "
sound is heard once, which means the start of this operation.
When power switch is turning on for the first time and
emergency operation starts, the unit will run automatically in
the following modes:
Room
temperature
Designated
temperature
Timer
mode
Fan
speed
Operation
mode
Above 23
o
C
Below 23
o
C
23
o
C
26
o
C
No
AUTO
AUTO
COOL
HEAT
No
It is impossible to change the settings of temp. and fan speed,It
is also not possible to operate in timer or dry mode.
temperature is below 16
o
C, do not use it in the
Test operation:
Use this switch in the test operation when the room
normal operation.
your finger from the switch: the cooling
Continue to press the test operation
switch for more than 5 seconds . After
you hear the "Pi" sound twice, release
Test ope ration switch is the same as emergency switch.
operation starts with the air flow speed "Hi".
Under this operation mode,the fan motor of indoor
unit will run in high speed.
LOW
MED
HI
AUTO
2. Select operation mode
COOL button:Cooling mode
HEAT button: Heating mode
DRY button: Dehumidify mode
Display
circulated
Pi
Pi Pi
DRY
COOL
AUTO
HEAT
FAN
In HEAT mode, warm air will blow out after
a
short
period of the time due to cold - draft prevention function.
When FAN is set to AUTO, the air conditioner automatically
adjusts the fan speed according to room temperature.
2
3
3
1
4
Remote controller
Press button again ,
vertical flap will stop over
present position,
the swing function will be cancelled
2.Press button. changes as follows:
COOL/DRY/AUTO(Initial state):
HEAT(Initial state):
1.Vertical flap
Pos.1
Pos.2
Pos.3
3.Press
button
to choose the Pos.2 and Pos.3.
Pos.4
Pos.5
Pos.4
(Autoswing)
(no)
2
Cooling only unit do not have displays and functions
related with heating
Summary of Contents for AS25TABHRA-TCS
Page 91: ...1 2m2 8 H07RN F 3mm R32 1 2 5 8 9 10 A R32...
Page 96: ...17 22 26 17 19 26 l l l l l l l l l l l FC R32 15 10 10 2m...
Page 99: ...8 40 C 1 2 3 4 FRONT stopper 5 1 2 4 5 l 6 l l 3 OFF M...
Page 100: ...9 1 2 3 OFF...
Page 113: ...1 2 5 6 R32 1 2 2 H07RN F 3 R32...
Page 114: ...1 2 3 4 4 4 F N D 6 8 F N D circulated 1 4 5 9 11 14 15 16 8 19 18 6 1 2 3 4 5 1 2 3 1 2 3 1...
Page 115: ...1 2 3 3 1 4 26 2...
Page 116: ...4 3 HEALTH HEALTH...
Page 118: ...5...