SERVICE MANUAL
Model:AFD626TGW/R/B
21
Issue 2010-10-25
Rev. Ref1010S025V0
the button A+B+C on the door
display panel at the same time
for 3 seconds to enter the T4
MODE, the door display panel
displays T4 T4 T4, and the
refrigerator enters a Special
Mode
freezer fan motor shall be forced
operated,
2) The damper is open,
3) The defrosting heater wire is
disconnected,
4) The fridge compartment
operates normally.
EXIT
In the T4 MODE, press and hold
the button A+B+C on the door
display panel at the same time
for 3 seconds to Exit TEST
MODE
The door display panel will
resume normal display
/