Commercial Air Conditioner
Model: AD09/12/14/182XLERA
-7
-
3. Installation Instructions
6. The breaker of the air conditioner should be all-pole
switch; and the distance between its two contacts
should be no less than 3mm. Such means for
disconnection must be incorporation in the fixed wiring.
7. The waste battery shall be disposed properly.
8. The appliance is not intended for use young children
or infirm persons without super vision.
9. Young children should be supervised to ensure that
they do not play the appliance.
Do not obstruct or cover the ventilation
grille of the air conditioner. Do not put fingers
or any other things into the inlet/outlet and
swing louver.
Do not allow children to play with the air
conditioner. In no case should children be
allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
The machine is adaptive in following
situation:
1.Applicable ambient temperature range:
2. If the supply cord is damaged, it must be
replaced by the manufacturer or its service
agent or a similar qualified person.
3. If the fuse on PC board is broken, please
change it with the type of T 3.15A /250VAC.
4. The wiring method should be in line with
the local wiring standard.
5. The power cable and connecting cable are
self-provided.
The requirement of the connecting cable:
All the cables shall have got the local
authentication certificate.
Cooling
Heating
Indoor
outdoor
Rated Maximum Minimum
27 32 18
19 23 14
35 43 10
24 26 6
20 27 15
14.5 -- --
7 24 -15
6 18 --
DB C
WB C
DB C
WB C
Indoor
outdoor DB C
WB C
DB C
WB C
Cautions
Model
Power cable: H05RN-F 3G 2.5mm
2
AD092XLERA
AD122XLERA
AD142XLERA
AD182XLERA
Connecting cable
Signal wires: H05RN-F 2X1.5mm
2