WIRED CONTROLLER

ENGLISH

noTe: The display backlight must be illumi-
nated before proceeding. To turn the back-
light on, press any key (MoDe, fan, 

pq

TIMe, or seT) located at the bottom of the 
display, or press the on/off key located at 
the top of the display.

 

Timer on

Press the TIMER key once, the ON timer icon will appear in the 
upper right corner of the screen. The ON icon and hour po

-

sition are flashing. Press the 

pq

 keys to set the hour.  Press 

the TIMER key again, the ON icon and minutes position are 
now flashing. Press the 

pq

 keys to set the minutes. Press the 

SET key to confirm the setting. 

Timer off

Press the TIMER key 3 times, the OFF timer icon will appear in 
the upper right corner of the screen. The OFF icon and hour 
position are flashing. Press the 

pq

 keys to set the hour.  

Press the TIMER key again, the OFF icon and minutes position 
are now flashing. Press the 

pq

 keys to set the minutes. Press 

the SET key to confirm the setting.

Timer on/off

Press the TIMER key 5 times, the ON/OFF timer icon will ap

-

pear in the upper right corner of the screen. The ON icon and 
hour position are flashing. Press the 

pq

 keys to set the hour.  

Press the TIMER key again, the ON icon and minutes position 
are now flashing. Press the 

pq

 keys to set the minutes. Press 

the TIMER key again, the OFF icon and hour position are now 
flashing. Press the 

pq

 keys to set the hour. Press the TIMER 

key again, the OFF icon and minutes position are now flashing. 

Press the 

pq

 keys to set the minutes. Press the SET key to 

confirm the setting. Based on the times set, the indoor unit 
will determine which event happens first (ON-OFF or OFF-
ON) and adjusts the arrow direction accordingly. 

If neither 

pq

 key is pressed within 10 seconds, or if the 

MODE, FAN, or ON/OFF keys are pressed prior to pressing the 
SET key, the setting function is canceled and reverts back to 

the previous setting.

Timer Cancel

Press the TIME key up to 9 times to cycle through the timer 
settings. When the timer icon disappears, the timer function is 

canceled.

note:

  An active timer function will remain displayed on screen 

until the set time has been reached and command completed. 

Timer function setting

oPeraTIon

settings & functions

Press the SET key. The swing louver function icon will 

be displayed. Press the 

pq

 keys to advance through 

the functions to select ECO function. (The icon will 

be flashing) Press the SET key to confirm the setting. The ECO 

icon will remain on.

To cancel ECO function, repeat the above steps.

NOTE: The energy saving default parameters are listed below:

74°F Lowest temperature limit of Cooling and Dry mode.

78°F Highest temperature limit of Heating mode.
74°F – 86°F Temperature adjustment range in Cooling and Dry 

mode. 

60°F – 78°F Temperature adjustment range in Heating mode.

ECO

for Cooling

Under Cooling mode, set the temperature to 86°F. Press and 
hold the FAN key for 5 seconds. The Cooling ECO parame

-

ter (flashing) will be displayed in the upper left corner of the 

screen. Default temperature is 74°F. Press the 

pq

 keys to 

adjust the lowest target cooling temperature. Press the SET 
key to confirm the setting and exit setup. 

for Heating

Under Heating mode, set the temperature to 60°F. Press and 
hold the FAN key for 5 seconds. The Heating ECO parameter 
(flashing) will be displayed in the upper right corner of the 

screen. Default temperature is 78°F. Press the 

pq

 keys to 

adjust the highest target heating temperature. Press the SET 
key to confirm the setting and exit setup. 

Press and hold the SET and FAN keys for 5 seconds. The cur

-

rent static pressure will be displayed in the upper right corner 

of the screen and the “Static Pressure” icon will begin to flash. 

Press the TIME key to shift the unit no. displayed in the upper 

left corner of the screen. The unit numbers are from 00-15.
Press the 

pq

 keys to change the static pressure grade, 

shown in the upper right corner of the screen.

Number range is 01-04. Press the SET key to confirm the 
setting.  Press the MODE, FAN, or ON/OFF key to exit the 
function. If no key is pressed in 10 seconds, the function will 

also exit. 

noTe:  This function requires the  on/off key leD to be 
turned on and the screen backlight to be illuminated. 

noTe:  This function requires the  on/off key leD to be 
turned on and the screen backlight to be illuminated. 

noTe:  This function requires the  on/off key leD to be 
turned on and the screen backlight to be illuminated. 

eCo energy saving function

eCo Parameter setting

static Pressure Grade Inquiry & adjustment

Summary of Contents for AB09SC2VH2

Page 1: ...tures and Interface 2 Installation 3 4 Wired Controller Wiring Instructions 3 4 Dip Switch 4 Operation 5 8 Settings Functions 5 8 This system should be installed by a qualified HVAC professional Incorrect installation may cause fire water damage personal injury or death When abnormalities such as a burnt smell are detected immediately power off the main switch and contact a licensed contractor Do ...

Page 2: ...ample if the temp is 25 C 77 F it will display 25 C 77 F Humidity display function is reserved Energy Saving function This icon will be dis played only when energy saving function is set Filter Cleaning Child Lock Lock Central Motion Sensing Reserved Left Right Swing This icon is displayed only when in swing function Up Down Swing This icon is displayed only when in swing function Sleep function T...

Page 3: ...G 0 75mm2 x3 core shielded wire 300 400 ft 90 120m 16AWG 1 25mm2 x3 core shielded wire 400 500 ft 120 150m 14AWG 2mm2 x3 core shielded wire A One wired controller controls one indoor unit the indoor unit connects with the wired controller through a 3 conductor shielded cable C Two wired controllers control one indoor unit The wired controller that connects with the indoor unit is called the master...

Page 4: ...nt temp display available OFF OFF Ambient temp display unavailable SW1 3 ON Display ambient temp from PCB of indoor OFF OFF Display ambient Temp from wired controller SW1 4 ON Auto restart invalid OFF OFF Auto restart valid SW1 5 ON Fahrenheit OFF OFF Celsius SW1 6 ON Swing angle adjustment available OFF OFF Swing angle adjustment unavailable SW1 7 ON Up Down and Left Right swing OFF OFF Up Down s...

Page 5: ...the clock will default to 12 00 Within 10 seconds of the clock be ing displayed the time can be set The clock icon and minutes portion of the time display will be flashing Press the pq keys to adjust the minutes Pressing and holding the pq keys will accelerate the time adjustment With the minutes set press the TIME key The clock icon and hours portion of the time display will now begin flashing Pr...

Page 6: ...eted Timer Function Setting OPERATION Settings Functions Press the SET key The swing louver function icon will be displayed Press the pq keys to advance through the functions to select ECO function The icon will be flashing Press the SET key to confirm the setting The ECO icon will remain on To cancel ECO function repeat the above steps NOTE The energy saving default parameters are listed below 74...

Page 7: ...s The child lock icon will disappear from the screen All normal functions of the keys will be restored Note This function requires the ON OFF key LED to be turned OFF and the screen backlight to be illuminated Press and hold the FAN keys for 5 seconds the current temperature compensation value is displayed in the upper right corner of the screen The default value is 00 Press the pq keys to change ...

Page 8: ...N OFF key LED to be turned ON and the screen backlight to be illuminated Filter Cleaning OPERATION Settings Functions Press the SET key The swing louver function icon will be displayed Press the pq keys to advance through the functions to select the Heat Reclaim Ventilation function The icon will be flashing Press the SET key to confirm the setting To cancel the Heat Reclaim Ventilation function r...

Page 9: ...www Haier com Haier America Wayne NJ 07470 2015 Haier America Trading LLC Model YR E17 Issued Date May 2015 ...

Reviews: