background image

 

3

 

1. SAFETY 

PRECAUTIONS 

1. 

The design of this product contains special hardware, many 
circuits and components especially for safety purposes. For 
continued  protection,  no  changes  should  be  made  to  the 
original  design  unless  authorized  in  writing  by  the 
manufacturer. Replacement parts must be identical to those 
used in the original circuits. Service should be performed by 
qualified personnel only. 

 
2. 

Alterations  of  the  design  or  circuitry  of  the  products  should 
not be made. Any design alterations or additions will void the 
manufacturer

s  warranty  and  will  further  relieve  the 

manufacturer of responsibility for personal injury or property 
damage resulting therefrom. 

 
3. 

Many  electrical  and  mechanical  parts  in  the  products  have 
special  safety-related  characteristics.  These  characteristics 
are  often  not  evident  from  visual  inspection  nor  can  the 
protection afforded by them necessarily be obtained by using 
replacement  components  rated  for  higher  voltage,  wattage, 
etc.  Replacement  parts  which  have  these  special  safety 
characteristics  are  identified  in  the  parts  list  of  Service 
manual.  Electrical  components  having  such  features  are 
identified  by  shading  on  the  schematics  and  by  ( 

    )  on 

the  parts  list  in  Service  manual.  The  use  of  a  substitute 
replacement  which  does  not  have  the  same  safety 
characteristics  as  the  recommended  replacement  part 
shown in the parts list of Service manual may cause shock, 
fire, or other hazards 

 
4. 

Don

t  short  between  the  LIVE  side  ground  and 

ISOLATED  (NEUTRAL)  side  ground  or  EARTH  side 
ground  when  repairing

.  Some  model

s  power  circuit  is 

partly  different  in  the  GND.  The  difference  of  the  GND  is 
shown  by  the  LIVE:  (      )  side  GND,  ISOLATED   
(NEUTRAL): (      ) side GND and EARTH: (        ) side GND. 
Don

t  short  between  the  LIVE  side  GND  and  ISOLATED 

(NEUTRAL)  side  GND  or  EARTH  side  GND  and  never 
measure with a measuring apparatus (oscilloscope etc.) the 
LIVE  side  GND  and  ISOLATED  (NEUTRAL)  side  GND  or 
EARTH side GND at the same time. If above note will not be 
kept, a fuse or any parts will be broken. 

 
5. 

If  any  repair  has  been  made  to  the  chassis,  it  is 
recommended  that  the  B1  setting  should  be  checked  or 
adjusted (See ADJUSTMENT OF B1 POWER SUPPLY). 

 
6. 

The high voltage applied to the picture tube must conform to 
that specified in Service manual. Excessive high voltage can 
cause  an  increase  in  X-Ray  emission,  arcing  and  possible 
component  damage,  therefore  operation  under  excessive 
high  voltage  conditions  should  be  kept  to  a  minimum,  or 
should be prevented. If severe arcing occurs, remove the AC 
power  immediately  and  determine  the  cause  by  visual 
inspection  (incorrect  installation,  cracked  or  melted  high 
voltage harness, poor soldering, etc.). To maintain the proper 
minimum  level  of  soft  X-Ray  emission,  components  in  the 
high  voltage circuitry including the  picture tube  must  be the 
exact  replacements  or  alternatives  approved  by  the 
manufacturer of the complete product. 

 
7. 

Do  not  check  high  voltage  by  drawing  an  arc.  Use  a  high 
voltage  meter  or  a  high  voltage  probe  with  a  VTVM. 
Discharge  the  picture  tube  before  attempting  meter 
connection,  by  connecting  a  clip  lead  to  the  ground  frame 
and connecting the other end of the lead through a 10k

Ω

 2W 

resistor to the anode button. 

 
8. 

When  service  is  required,  observe  the  original  lead  dress. 
Extra  precaution  should  be  given  to  assure  correct  lead 
dress in the  high  voltage circuit  area. Where  a short circuit 
has  occurred,  those  components  that  indicate  evidence  of 
overheating  should  be 

replaced. 

Always  use  the 

manufacturer

s replacement components. 

9. 

Isolation Check 
(Safety for Electrical Shock Hazard) 
After re-assembling the product, always perform an isolation 
check  on  the  exposed  metal  parts  of  the  cabinet  (antenna 
terminals,  video/audio  input  and  output  terminals,  Control 
knobs,  metal  cabinet,  screw  heads,  earphone  jack,  control 
shafts, etc.) to be sure the product is safe to operate without 
danger of electrical shock. 

10.  The surface of the TV screen is coated with a thin film which 

can easily be damaged. Be very careful with it when handle 
the TV.

 

Should the TV screen become soiled, wipe it with a 

soft dry cloth. Never rub it forcefully. Never use any cleaner 
or detergent on it.

 

 
(1)  Dielectric Strength Test 

The  isolation  between  the  AC  primary  circuit  and  all  metal 
parts  exposed  to  the  user,  particularly  any  exposed  metal 
part  having  a return path to the chassis should  withstand  a 
voltage of 3000V AC (r.m.s.) for a period of one second. 
(

Withstand a voltage of 1100V AC (r.m.s.) to an appliance 

rated  up  to  120V,  and  3000V  AC  (r.m.s.)  to  an  appliance 
rated 200V or more, for a period of one second.) 
This  method  of  test  requires  test  equipment  not  generally 
found in the service trade. 

(2)  Leakage Current Check 

Plug the AC line cord directly into the AC outlet (do not use 
line  isolation  transformers  during  this  check).  Using  a 

Leakage Current Tester

, measure the leakage current from 

each  exposed  metal  part  of  the  cabinet,  particularly  any 
exposed metal part having a return path to the chassis, to a 
known  good  earth  ground  (water  pipe,  etc.).  Any  leakage 
current must not exceed 0.5mA AC (r.m.s.). 
However,  in  tropical  area,  this  must  not  exceed  0.2mA  AC 
(r.m.s.). 

Alternate Check Method 

Plug the AC line cord directly into the AC outlet ( do not use 
a  line  isolation  transformer  during  this  check.).  Use  an  AC 
voltmeter  having  1000  ohms  per  volt  or  more  sensitivity  in 
the  following  manner.  Connect  a  1500

Ω

  10W  resistor 

paralleled  by  a  0.15

μ

F  AC-type  capacitor  between  an 

exposed  metal part  and  a  known  good  earth ground (water 
pipe, etc.). Measure the AC voltage across the resistor with 
the  AC  voltmeter.  Move  the  resistor  connection  to  each 
exposed  metal  part,  particularly  any  exposed  metal  part 
having  a  return  path  to  the  chassis,  and  measure  the  AC 
voltage across the resistor. Now, reverse the plug in the AC 
outlet and repeat each measurement. Any voltage measured 
must  not  exceed  0.75V  AC  (r.m.s.).  This  corresponds  to 
0.5mA AC (r.m.s.). 
However,  in  tropical  area,  this  must  not  exceed  0.3V  AC 
(r.m.s.). 
This corresponds to 0.2mA AC (r.m.s.) 

 

 

 

                    

                                             

                          

Summary of Contents for 21FA11-AM

Page 1: ...SERVICE MANUAL Colour Television Haier model 21FA11 AM Customer model HTAF21S CAUTION READ THIS MANUAL CAREFULLY TO DIAGNOSE TROUBLE CORRECTLY BEFORE OFFERING SERVICE ...

Page 2: ...cement of memory IC 5 4 Service adjustment 5 5 ICs functional description 8 6 Test point waveform 10 7 All ICs voltages 10 8 Purity convergence adjustment 11 CONTENTS 1 Safety precautions 3 2 TV block dia g ram 4 ...

Page 3: ...not check high voltage by drawing an arc Use a high voltage meter or a high voltage probe with a VTVM Discharge the picture tube before attempting meter connection by connecting a clip lead to the ground frame and connecting the other end of the lead through a 10kΩ 2W resistor to the anode button 8 When service is required observe the original lead dress Extra precaution should be given to assure ...

Page 4: ... 4 2 Block diagram TDA8378PS N2 series with mono intercarrier sound demodulator ...

Page 5: ...data adjustment of corresponding factory menus Press EXIT key to exit factory mode Focus adjustment 1 Receive a crosshatch signal 2 While watching the screen adjust the FOCUS VR on the FBT to make the vertical and horizontal lines as fine and sharp as possible Geometrical adjustment Receive PAL standard complete pattern signal Adjustment steps a Adjust VSL to the centre horizontal line just appear...

Page 6: ...t 0 A 0BRI Listen Brightness 0 A 0COL Listen Colour 50 A 0SHP Listen Sharpness 50 A 1CON Soft Contrast 45 A 1BRI Soft Brightness 45 A 1COL Soft Colour 50 A 1SHP Soft Sharpness 50 A 6 Picture preset 2 2CON Standard Contrast 75 A 2BRI Standard Brightness 50 A 2COL Standard Colour 50 A 2SHP Standard Sharpness 60 A 3CON Dynamic Contrast 85 A 3BRI Dynamic Brightness 60 A 3COL Dynamic Colour 60 A 3SHP D...

Page 7: ...on Description Preset Remark Bit 6 HALFTONE 1 Enable 1 EA Bit 5 IDENT_SENSITIVE 1 EA Bit 4 HCO 1 Enable 0 EA Bit 3 LOGO 1 EA Bit 2 TILT 0 EA Bit 1 SPANISH 1 EA Bit 0 ROMANIA 0 EA 5 OP5 Bit Function Description Preset Remark Bit 7 STORE_AV 1 Enable 1 EA Bit 6 OSO 1 Enable 0 EA Bit 5 SOFR_CHANGE 1 Enable 0 EA Bit 4 FADE 1 Enable 0 EA Bit 3 SOUND_M 1 Enable 0 EA Bit 2 SOUND_I 1 Enable 0 EA Bit 1 SOUN...

Page 8: ... DESCRIPTION STAND BY output 1 In STAND BY mode low level Power OFF For Power ON this pin will be high SCL 2 I2 C bus clock line SDA 3 I2 C bus data line TUNING 4 tuning Voltage Vt PWM output KEY 5 Control keys input SYSTEM 6 TV system control VOL 7 Sound Volume control PWM output MUTE 8 Sound mute output VSSC P 9 Digit ground for μ controller core and periphery CTL 10 DVD power control STANDBY 11...

Page 9: ... B input U B Y input PB input BCLIN 49 Beam current limiter input BLKIN 50 Black current input RO 51 Red output GO 52 Green output BO 53 Blue output VDDA 54 Analog supply of Closed Caption decoder and digital supply of TV processor 3 3 V VPE 55 Ground VDDC 56 Digital supply to core 3 3 V OSCGND 57 Oscillator ground supply XTALIN 58 Crystal oscillator input XTALOUT 59 Crystal oscillator output RESE...

Page 10: ...al output V FEEDBACK 9 Vertical feedback GND 5 Ground 5 U101 Tuner PIN Function PIN Function 1 AGC 7 5V 2 vacant 8 vacant 3 Gnd 9 Vt 33V 4 SCL 10 Gnd 5 SDA 11 IF Out 6 5V 6 Test point Waveforms 7 IC voltages 5Vpp 0 9Vpp 1 3Vpp H H 1Vpp V CRT KB CRT KG CRT KR 95Vpp 95Vpp 95Vpp H H H TDA8378IN53 2 5Vpp 2 5Vpp 3 8Vpp H H H TDA8378N52 TDA8378IN51 TDA8378IN33 TDA8378IN34 0 8Vpp V TDA8378IN21 TDA8378IN2...

Page 11: ... 38 39 40 41 42 43 44 45 46 47 48 V 0 5 0 3 0 1 7 2 4 3 4 8 3 9 0 3 3 0 3 6 1 4 2 5 2 5 2 5 PIN 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 V 1 9 5 0 2 4 2 4 2 4 3 1 0 3 2 0 1 8 1 7 0 3 2 5 1 3 3 5 TDA8357 PIN 1 2 3 4 5 6 7 8 9 V 0 8 0 7 16 6 9 0 43 7 2 0 3 7 2 AN 7522N PIN 1 2 3 4 5 6 7 8 9 10 11 12 V 10 4 4 0 4 4 2 75 1 4 0 1 4 0 35 4 4 0 4 4 24C08 PCF8598 PIN 1 2 3 4 5 6 7 8 V 0 0 5 1 0 3 2...

Page 12: ...the screen Fig 3 8 Move the deflection yoke forward and fix the position of the deflection yoke so that the whole screen will become green 9 Insert the wedge to the top side of the deflection yoke so that it will not move 10 Input a crosshatch signal 11 Verify that the screen is horizontal 12 Input red and blue raster signals and make sure that purity is properly adjusted CRT WEDGE DEFLECTION YOKE...

Page 13: ...t convergence DYNAMIC CONVERGENCE ADJUSTMENT 1 Move the deflection yoke up and down and overlap lines in the periphery Fig 2 2 Move the deflection yoke left to right and overlap the lines in the periphery Fig 3 3 Repeat 1 and 2 above and make the best convergence After adjustment fix the wedge at the original position Fasten the retainer screw of the deflection yoke Fix the 6 magnets with glue FRO...

Page 14: ...6W 100K R303 2W 220 R307 EWD DEC BG PH1 LF GND3 PH2 LF DECD G SEC PLL VSSA CTL BAND VSSC P VOL MUTE SYSTEM KEY 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 47 48 49 50 51 52 53 54 55 56 57 58 59 60 VP2 46 23 24 25 26 27 28 29 30 31 32 45 33 34 39 40 41 42 35 36 37 38 43 44 H OUT F B L SO AUO EXT EHTO PLL IF IF VO SVO VP1 CVPS INT GND1 CVBS Y CHROMA AUD OUT V DRB V BRA IF IN1 IF IN2 I REF V S C...

Page 15: ...14 Sincere Forever ...

Reviews: