Single Split
3
Outdoor unit
Unit model (color)
1U48IN1EAB
Compressor
Model / Manufacture
ATE518SC3Q9RKA/Shanghai Hitachi
Elctrical Appliances Co.,Ltd
Oil model
α68HES-H
Oil type
α68HES-H
Oil charging
1600ml
Type
Rotary
Protection type
Inner thermal protection
Starting method
direct start
Fan
Type × Number
axial×2
Speed
r/min
840±30/520±40
Fan motor output power
kW
0.07
Air-flow(H-M-L)
m³/h
6500
Heat exchanger
Type / Diameter
mm
TP2U/Φ9.52
Row / Fin pitch
2/1.75
Dimension
External
(
L×W×H
)
mm×mm×mm
960×340×1250
Package
(
L×W×H
)
mm×mm×mm
1095×410×1400
Drainage pipe (material , I.D./O.D.)
mm
none
Refrigerant control method
mm/mm
capillary
Defrosting
auto
Volume of Accumulator
L
3
Noise level
dB(A)
58
Type of Four way valve
DSF-20
material of reduce noise
XPE
crankcase heater power
W
40
PIPING
Refrigerant
Type / Charge
g
R410A/3400
Recharge quantity
g/m
65
Pipe
Liquid
mm
φ9.52
Gas
mm
φ19.05
Connecting Method
Flared
Between I.D
&O.D
MAX.Drop
m
20
MAX.Piping length
m
30
Norminal condition: indoor temperature (cooling): 27
℃
DB/19
℃
WB, indoor temperature (heating): 20
℃
DB
Outdoor temperature(cooling): 35
℃
DB/24
℃
WB, outdoor temperature(heating): 7
℃
DB/6
℃
WB
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound
intensity meter. It is a sound pressure noise level. The detailed method please refer to the following information:
Summary of Contents for 1U48IN1EAB
Page 8: ...Single Split 6 5 Installation 1 2 1 2 3 4 1 2 1 2 3 4 2 ...
Page 9: ...Single Split 7 ...
Page 10: ...Single Split 8 ...
Page 11: ...Single Split 9 ...
Page 12: ...Single Split 10 ...
Page 13: ...Single Split 11 ...
Page 14: ...Single Split 12 ...
Page 15: ...Single Split 13 ...
Page 16: ...Single Split 14 pipe direction Right Left Rear Bottom Indoor outdoor unit connection ...
Page 27: ...Single Split 25 8 PCB photo Indoor PCB 0010451850 ...