17
Domestic air conditioner
Functions and control
F-MIN-d(compressor’s Min_hz)< F<F-MAX-d(compressor’s Max_hz)
When heating, it is needed to satisfy
F-MIN-r (compressor’s Min_hz)< F<F-MAX-r (compressor’s Max_hz)
PID control :
The innital frequency Sn is determined by Pn . We can calculate Hzoutf according to the value of Kp ,Ki ,Kd,
Out_gain,Pn.Then , Fn = Sn + Hzoutf. The value of Fn is calculated in each sample time (60 seconds),and Fn is
adujusted according to previous frequency of Sn and filtered output of Hzoutf.
7.1.2 The outdoor fan control (Exchange fan)
When the fan is changed among every airflow speed (including stop blowing), in order to avoid the
airflow speed from skipping frequently, it must be kept under each mode for over 30 seconds, and then
it can be changed to another mode (when refrigerating, the time is changed to 15 seconds).
7.1.2.1 The outdoor fan control
Within three minutes of compressor starting, the compressor is controled according to the ambient temperature.
Tao
Tao <22
22 < Tao <29
Tao 29
Refrigeration/dehumidification
(12K)
400r/min
600r/min
760r/min
Tao
Tao <<10
10 < Tao <17
Tao 17
Heating
400r/min
After 3 minutes, the compressor is controled according to the ambient temperature and the frequency of the
compressor.
Refrigeration/dehumidification
frequency Hz 12 K
<41 Hz
41 Hz -62 Hz
62 Hz
Tao
22
400r/min
500r/min
600r/min
22-29
500r/min
600r/min
760r/min
29
760r/min
Heating frequency Hz
(12K)
<61 Hz
61-74 Hz
74 Hz
Tao
10
760r/min
760r/min
800r/min
10-17
600r/min
760r/min
800r/min
17
600r/min
800r/min
760r/min
Summary of Contents for 1U35YEGFRA
Page 11: ...Piping diagrams Domestic air conditioner 4ˊPiping diagrams 9 ...
Page 12: ...Operation range 10 Domestic air conditioner 5 Operation range 10 0 21 27 35 20 40 60 43 20 40 ...
Page 37: ...Service diagnosis 37 Domestic air conditioner ...
Page 56: ...57 Do C omestic air ircuit Diagra conditioner ams r ...
Page 59: ...Removal Procedure 1 Removal of Outdoor panel RPHVWLF LU RQGLWLR ...
Page 60: ...Removal Procedure 2 Domestic Air Condition ...
Page 61: ...4 Removal Procedure 3 Domestic Air Condition ...
Page 62: ...Removal Procedure 2 Removal of Electrical Box RPHVWLF LU RQGLWLR ...
Page 63: ...Removal Procedure 3 Removal of Fan and Fan Motor RPHVWLF LU RQGLWLR ...
Page 64: ...Removal Procedure 4 Removal of fan motor brcked and partition RPHVWLF LU RQGLWLR ...
Page 65: ...Removal Procedure 7 Domestic Air Condition ...
Page 66: ...Removal Procedure 5 Removal of compressor and heat exchanger RPHVWLF LU RQGLWLR ...