Performance and
curves
diagrams
55
Domestic air conditioner
11.4 Cooling suction pressure curves
outdoor temp.
(humidity 46%)
DB/WB
21/15
℃
27/19
℃
35/24
℃
-20
℃
692
853
981
-10
℃
729
898
1032
0
℃
759
935
1075
8
℃
782
964
1109
15
℃
798
984
1131
20
℃
806
993
1143
25
℃
849
1004
1166
30
℃
893
1056
1178
35
℃
941
1067
1240
38
℃
990
1100
1265
40
℃
1089
1210
1392
43
℃
1198
1307
1517
indoor temp.
performance curves
cooling suction pressure.table
350
550
750
950
1150
1350
1550
1750
-20℃-10℃0℃ 8℃ 15℃20℃25℃30℃35℃38℃40℃43℃
su
ct
io
n
pr
essu
re
(
K
pa
)
outdoor temp.(DB/WB)
cooling suction pressure and temp
.
curves
21/15℃
27/19℃
35/24℃