Installation instruction
The following is the manual mentioned
standard accessories, please check them by
yourself.
Amount
6
Name
Use screw bolt (M10) and screw nut to tightly fix the outdoor unit on its bracket, and
keep it level.
When install on the wall or roof, fix the bracket firmly and reliably to prevent from
the attack of earthquake or strong wind.
In order to lower the vibration, the rubber cushion must be installed.
The installation slant degree of the unit should be less than 3
*
.
190
580
380
190
Installation dimension of outdoor unit (mm)
Install and fix
Installation tools
Standard accessories (self-provided installation parts)
Mark
Name of
parts
A
B
C
Adhesive
tape
Pipe supporting
plate
Connection
hose
Drain hose Thermal insulation
material
Plaster powder
F
E
D
Warning
During installation, if the refrigerant leaks, please immediately take ventilation
measure.
Once the leaked refrigerant gas meet fire, poisonous gas will be generated.
After finishing installation, make sure the refrigerant gas will not lead.
1. Connection method of pipe
(1)The joint of refrigerant connection pipe is at the right side of the outdoor unit.
(2)The connection pipe can be connected out from the right side of outdoor unit.
For single system, the max length of connection pipe is 15m and the max fall is 5m.
In order to guarantee efficiency, the connection pipe should as short as possible.
Daub the refrigerant oil on the joint and flare.
1.Screwdriver 2. Steel saw
3. Pipe cutter 4. Pipe flarer
5. Knife 6. 70mm diameter drill
7. Leakage detector/soap water
8. Spanner (diameter 17,27mm)
9. Spanner (14, 17, 19, 27mm)
10. Pincers 11. Tape measure
12. Scraper 13. Refrigerant oil
14.Vacuum pump 15. Nitrogen tank
Shape
Putty
Rubber cushion
Refrigerant oil
Plastic clamp
Manual
Connection of pipe
4
1
***
1
1
4