background image

If the wind speed is high or middle before
setting for the sleep, set for lowing the wind
speed after sleeping.
If it is low wind, no change.

4.Set the wind speed change when sleeping

Before going to bed, you can simply press the
SLEEP button and unit will operate in SLEEP
mode and bring you a sound sleep.
Use of SLEEP function
After the unit starts, set the operation status,
then press SLEEP button before which the
clock must be adjusted and time being set.
Operation Mode
1. In COOL,DRY mode
  1 hours after SLEEP mode starts, temp. will
  become 1

O

C higher than temp. setting. After

  another 1 hours, temp. rises by 1

O

C further.

  The unit will run for further 6 hours then stops.
  Temp. is higher than temp. setting so that room
  temperature won't be too Iow for your sleep.

Remote Controller

SLEEP operation starts

SLEEP operation stops

Approx.6hrs

1 hr

Rises 1

O

C

Rises 1

O

C

Temp.setting

Unit stop

In COOL, DRY mode

1 hr

Sleep Operation

2. In AUTO mode

The unit operates in corresponding sleep
mode adapted to the automatically selected
operation mode.

3. In FAN mode
    It has no SLEEP function.

Operation

15

STERILIZE

FRESH

Summary of Contents for 1050

Page 1: ...No 001050 SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL Please read this operation manual before using the air conditioner HSU 09LH13 HSU 12LH13 ...

Page 2: ... disposal services nearest to your house Disposal of the packaging of your new air conditioner Before starting the air conditioner read the information given in the User s Guide caref ully The User s Guide contains very impor tant observations relating to the assembly operation and maintenance of the air conditioner The manufacturer does not accept respon sibility for any damages that may arise du...

Page 3: ...e is adaptive in following situation 10 The power plug and connecting cable must have acquired the local attestation 2 If the power supply cord is damaged it must be replaced by the manufacturer or its service agent or a similar qualified person 3 If the fuse of indoor unit on PC board is broken please change it with the type of T 3 15A 250V 4 The wiring method should be in line with the local wir...

Page 4: ...se Please call Sales Service Shop for the Installation Do not attempt to install the air conditioner by yourself because improper works may cause electric shock fire water leakage lnstallation in a inadequate place may cause accidents Do not install in the following place Connect the earth cable earthing Do not install in the place where there is any possibility of inflammable gas leakage around t...

Page 5: ...cially at infants or the aged Do not try to repair or reconstruct by yourself Do not use for the purpose of storage of food art work precise equipment breeding or cultivation CAUTION Take fresh air occasionally especially when gas appliance is running at the same time PROHIBITION STRICT ENFORCEMENT Do not operate the switch with wet hand PROHIBITION PROHIBITION 4 PROHIBITION PROHIBITION PROHIBITIO...

Page 6: ...HOSE Actual inlet grille may vary from the one shown in the manual according to the product purchased Display board Inlet Anion generator Vertical flap Use remote controller to adjust up and down air flow Don t adjust it manually Horizontal louver Air filter Inlet grille inside adjust left and right air flow inside ...

Page 7: ...isplay Remote controller to display the TEMP setting 22 TEMP display 23 TIMER OFF display 24 CLOCK display 25 TEMP button Used to select fan speed LOW MED HI AUTO 26 FAN button Used to set the health airflow mode 27 HEALTH AIRFLOW button 28 SWING UP DOWN button Used to select up or down air sending direction 29 SWING LEFT RIGHT button Used to select left right air flow 30 FRESH button Used to conf...

Page 8: ...le as well Don t throw or knock the remoter controller When electronic started type fluorescent lamp or change over type fluorescent lamp or wireless telephone is installed in the room the receiver is apt to be disturbed in receiving the signals so the distance to the indoor unit should be shorter Loading of the battery Load the batteries as illustrated right 2 R 03 7 batteries Remove the battery ...

Page 9: ...conditioner can generate a lot of anion effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room When indoor fan motor is running it has healthy process function It s available under any mode Press ON OFF on the remote controller unit starts Press HEALTH button For each press is disp...

Page 10: ...ows Remote controller Then Select Auto operation AUTO COOL DRY FAN Press FAN button For each press fan speed changes as follows Remote controller Press TEMP button Every time the button is pressed temp setting increase 1 C if kept depressed it will increase rapidly Every time the button is pressed temp setting decrease 1 C if kept depressed it will decrease rapidly Select a desired temperature 4 F...

Page 11: ...ssed it will increase rapidly Every time the button is pressed temp setting decrease 1o C if kept depressed it will decrease rapidly Select a desired temperature 4 Fan speed selection 3 Select temp setting 5 Unit stop Air conditioner is running under displayed fan speed When FAN is set to AUTO the air conditioner automatically adjusts the fan speed according to room temperature Press ON OFF button...

Page 12: ...ect a desired temperature 4 Fan speed selection 3 Select temp setting 5 Unit stop Press ON OFF button the unit stops COOL operation starts when room temp is higher than temp setting On reaching temp setting 2o C unit will run in mild DRY mode Ultra low air flow Temp setting 2o C Temp setting AUTO LOW MED HI AUTO COOL DRY FAN Operation Dry Operation 1 Unit start Press ON OFF on the remote controlle...

Page 13: ...ation 3 Fan speed selection 4 Unit stop About FAN operation In FAN operation mode the unit will not operate in COOL mode but only in FAN mode AUTO is not available in FAN mode And temp setting is disabled In FAN mode SLEEP operation is not available Press ON OFF button the unit stops AUTO LOW MED HI COOL DRY FAN Remote controller Operation 1 Unit start Press ON OFF on the remote controller unit st...

Page 14: ...swing according to the above positions AUTO 1 Status display of air sending Horizontal louvers Pos 1 Pos 2 Pos 3 Pos 4 Pos 5 Pos 6 Pos 7 Pos 8 3 Left and right air flow direction For each press of button remote controller displays as follows remote controller Pos 1 Pos 2 Pos 3 Pos 4 Pos 5 Pos 6 Pos 7 Pos 8 The horizontal louvers will swing according to the above positions Note When restart after r...

Page 15: ... set Operation Mode 1 In COOL DRY mode 1 hours after SLEEP mode starts temp will become 1O C higher than temp setting After another 1 hours temp rises by 1O C further The unit will run for further 6 hours then stops Temp is higher than temp setting so that room temperature won t be too Iow for your sleep Remote Controller SLEEP operation starts SLEEP operation stops Approx 6hrs 1 hr Rises 1O C Ris...

Page 16: ...pressed display changes as follows Remote controller BLANK TIMER ON TIMER OFF TIMER ON OFF Then select your desired TIMER mode TIMER ON or TIMER OFF or will flash 3 Time setting Press HOUR button Every time the button is pressed time setting increases 1 min if kept depressed it will increase rapidly Every time the button is pressed time setting decreases 1 min if kept depressed it will decrease ra...

Page 17: ...N OFF will flash 3 Time setting Press HOUR button Every time the button is pressed time setting increases 1 min if kept depressed it will increase rapidly Every time the button is pressed time setting decreases 1 min if kept depressed it will decrease rapidly It can be adjusted within 24 hours 4 Timer confirming for TIMER ON After setting correct time press TIMER button to confirm on the remote co...

Page 18: ...In this operation the system automatically selects the operation modes cooling or heating according to the room temperature Test operation Test operation switch is the same as emergency switch Use this switch in the test operation when the room temperature is below 16 O C do not use it in the normal operation Continue to press the test operation switch for more than 5 seconds After you hear the Pi...

Page 19: ...ation If the unit is not to be used for a long time turn off the power supply main switch Use the timer effectively Use the louvers effectively Do not block the air inlet or outlet Maintenance Proper temperature During cooling operation prevent the penetration of direct sunlight with curtain or blind 20 OFF ...

Page 20: ...letely fixed behind the stopper If the right and left filters are not attached correctly that may cause defects Remote Controller Do not use the following for cleaning Do not use water wipe the controller with a dry cloth Do not use glass cleaner or chemical cloth Gasoline benzine thinner or cleanser may damage the coating of the unit Hot water over 40 O C 104 O F may cause discoloring or deformat...

Page 21: ...urifying filter of the bacteria killing medium and the electrostatic air purifying filter accessories with machine will be used based on real situation The green aspect of the bacteria killing medium air purifying filter will face outside the white aspect will face to the machine and the white side of the electrostatic air purifying filter will face outside The bacteria killing medium air purifyin...

Page 22: ...e for 2 3 hours Put off the power supply cord Take out the batteries from the wireless remote controller Cleaning the body To prevent breeding mold or bad smell be sure to operate at the designated temperature or 30O C cooling mode and High speed fan mode for 2 3 hours Maintenance 23 ...

Page 23: ...he plug insert the plug of the power supply cord into the outlet completely In case of suing exclusive circuit breaker switch on the circuit breaker NO WET HAND EARTHING Operation without filter may cause troubles Be sure to attach both right and left filters prior to the operation Each of them are of different shapes Incomplete earthing may cause an electric shock Maintenance 24 ...

Page 24: ...ave elapsed to protect the system When the electric plug is pulled out and reinserted the protection circuit will work for 3 minutes to protect the air conditioner During unit operation or at stop a swishing or gurgling noise may be heard At first 2 3 minutes after unit start this noise is more noticeable This noise is generated by refrigerant flowing in the system During unit operation a cracking...

Reviews: