background image

3

WARNING!

Carefully read the following information in order to operate the air conditioner

correctly.

Below are listed three kinds of Safety Cautions and Suggestions.

Be sure to conform with the following important Safety Cautions.
The Safety Cautions should be at hand so that they can be checked at any  time whenneeded.
If the conditioner is transferred to the new user, this manual should be as well transferred
to the new user.

Safety precautions

Otherwise the one will feel unpleasant or harm

ones' health.

If any abnormal phenomena is found (e. g.

smell of firing), please cut off the power

supply immediately, and contact the dealer

to find out the handling method.

In such case, to continue

using the conditioner will

damage the conditioner,

and may cause electrical

shock or fire hazard.

When need maintenance and repairment,

call dealer to handle it.

Please let the dealer be responsible for
installing the conditioner.

Incorrect installation may cause water leak,
electrical shock and fire hazard.

Don't put fingers or any other things into

the inlet/outlet and swing louver while theconditioner is in operation.

Because the highspeed fan is very dangerous

and may cause injuries.

Call the dealer to take measures to preventthe refrigerant from leaking.

If conditioner is installed in a small room, be

sure to take every measure in order to prevent

suffocation accident even in case of refrigerant

leakage.

When conditioner is deinstalled or reinstalled

dealer should be responsible for them.

Incorrect installation may cause water leaking,

electrical shock and fire hazard.

Don't blow the human body with the cooling

air  too  long,  and  don't  let  the  room

temperature decrease too low either.

WARNING!

Incorrect operations may result in severe consequences of death or serious injuries.

CAUTION!

Incorrect operations may result in injuries or machine damages; in some cases may
cause serious consequences.

switch

off

INSTRUCTIONS:

These information can ensure the correct operation of the machine.

Incorrect mainten-

ance and repairment

may cause water

leak, electrical shock

and fire hazard.

Все каталоги и инструкции здесь:

 http

:

//splitoff.ru/tehn-doc.html

Summary of Contents for AD092XLERA

Page 1: ...ON INSTALLATION MANUAL AD092XLERA AD122XLERA AD142XLERA AD182XLERA R410A MULTI SPLIT SERIES ROOM AIR CONDITIONER No 0010577705 Please read this manual carefully before using this air conditioner Pleas...

Page 2: ...afety precautions Notes for safety Parts and Functions Trouble shooting Customer Need to know When trouble happens Operation and Maintenance Failure code 1 2 3 5 6 7 8 9 10 11 12 23 24 25 http splitof...

Page 3: ...fluorochlorichydrocarbon All th Consult your local authorities for the nameand address of the waste materialscollecting cente Safety Instructions and Warnings Before starting the air conditioner read...

Page 4: ...pecifications The refrigerating circuit is leak proof The machine is adaptive in followingsituation 1 Applicable ambient temperature range 2 If the supply cord is damaged it must bereplaced by the man...

Page 5: ...ay cause water leak electrical shock and fire hazard Don t put fingers or any other things into the inlet outlet and swing louver while theconditioner is in Because the highspeed fan is very dangerous...

Page 6: ...use acci dents Pets and plants should not be blowed directly in the air flow Otherwise will suffer damage Don t operate the air conditioner with damp hands Otherwise will be shocked Only use correctly...

Page 7: ...ating noise Air conditioner should be located in well vented and easily accessible place Air conditioner should not be located in thefollowing places a Places with machine oils or other oilva b Seasid...

Page 8: ...e remote controller Never connect the earth wire with the gas pipe water pipe lightening arrester or phone line Never install the air conditioner where the flammable gas is easily leaked Do not spray...

Page 9: ...Parts and Functions 7 INDOOR UNIT Electrical box Air inlet Drain pan Air outlet http splitoff ru tehn doc html...

Page 10: ...rbed by indoor unit During operation white fog comes out of indoor unit When in COOL or DRY mode a thin water fog can be seen blown out of unit this is the condensed fog because the suddenly cooled in...

Page 11: ...atically stops Water or vapor generated from the outdoor unit during heating This happens when the frost accumulated on the outdoor unit is removed during defrosting operation Defrosting operation Ple...

Page 12: ...tallation please use the air conditioner according to the specification in the operation manual Using Directions Adjust suitable airflow direction Avoid direct sunlight and airflow Keep the proper ind...

Page 13: ...he above mentioned items or when following phenomenon is observed stop the operation of the air conditioner and contact your sales dealer 1 The fuse or breaker often shuts down 2 Water drops off durin...

Page 14: ...res Execute the installation accurately based on following the installation manual Again improper installations can result in water leakage electric shocks and fires When a large air conditioning syst...

Page 15: ...angle 8 Pipe Expander Instructions to installation WARNING Its improper installation can also result in heat generation or fire When setting up or moving the location of the air conditioner do not mix...

Page 16: ...unit shall be ensured to receive thesignal while t 1 Drill a hole in the wall and insert the connecting pipe and wire through a PVC wall through tube purchased locally The wall hole shall be with a o...

Page 17: ...unit a specially designed return air bellows shall be installed as shown in Figure 3 Figure 4 Figure 3 Figure 4 A Installing building roof Ceiling Air supply Air outlet duct Unit Return air Return ai...

Page 18: ...rain piping of condensed water to keep warmth Figure 5 Figure 6 16 air return shutter air return duct sling dog drain piping transition air duct air outlet duct air diffuser joint of air diffuser M8 b...

Page 19: ...ulation layer is needed for air supply and return duct First paste a glue nail to the air duct and then attach the insulation cotton that has a tinfoil layer and use the glue nail cover to fix Finally...

Page 20: ...ause indoor water leakage CAUTION Requirements The indoor drain pipe shall be thermal insulated The connection part between the drain pipe and the indoor uni The drain pipe shall be slant downwards gr...

Page 21: ...pipe Drain confirmation During trial run check that there is no leakage at the pipe connection part during water draining even in winter 19 Rigid PVC pipe VP31 5mm internal diameter Pipe Foamed PE wit...

Page 22: ...LERA AD182XLERA Flare connection Gas pipe 3 way valve Indoor Unit Outdoor unit Liquid pipe 2 way valve Flare connection A To outdoor unit To gas pipe A adaptor from 9 52 to 12 7 6 35 mm 1 4 0 8 1 5 9...

Page 23: ...the address must be 3 Indoor unit that connect to valve D the address must be 4 2 Installation check and trial operation Check the Layout of the Drain Pipe and Connection Wires and also the piping an...

Page 24: ...ss it through the end ring of connecting line then connect it to the terminal block and tighten screw Wiring methods Ring Terminal T B Brazed seam B 8 0 9 0 mm d 4 3 5 3 mm T 1 0 2 0 mm For your refer...

Page 25: ...F 3G 2 5 mm2 POSSIBLE REASONS Faulty temperature sensor Tai 01 Sensor disconnected or broken or at wrong position or short circuit Faulty temperature sensor Tc1 Sensor disconnected or broken or at wro...

Page 26: ...ver current of the system or broken of the current sensor or malfunction with indoor or outdoor fan motors or faulty PCB 15 16 17 14 19 System high pressureprotection High pressure switch is disconnec...

Page 27: ...26 Faulty sensor Toci Sensor disconnected or broken or short circuit 2A Low voltage protection VDC 194V too low voltage from power source High voltage protection VDC 400V too high voltage from power...

Page 28: ...ROUP Qingdao Haier Air Conditioner Electric Co Ltd Address Haier Garden Qianwangang Road Economic Development Zone Qingdao Shandong 266555 P R China Web Site http www haier com http splitoff ru tehn d...