5.63 Flashing description

5.64 LED Display Function

system

state

operating

state

RUN

ALM

SOC

State

Shut

down

Dormancy

Off

Off

Off

Off

Off

Off

Total blackout

Standby

Normality

ON

Off

According to the quantity

indicator

Stand by

Charge

Normality

ON

Off

According to the quantity

indicator

Over current

Alarm

ON

Flashing2

According to the quantity

indicator

over voltage

protection

Flashing1

Off

Off

Off

Off

Off

Temperature

over current

protection

Flashing1

Off

Off

Off

Off

Off

Discharge

Normality

Flashing3

Off

According to the quantity

indicator

warn

Flashing3 Flashing3

Temperature

over current

and short

circuit

protection

Off

ON

Off

Off

Off

Off

When the mains is
offline, no action is

taken for 48 hours

before the

discharge is

stopped

Low-voltage

protection

Off

Off

Off

Off

Off

Off

6.User guide

Flashing

mode

ON

OFF

Flashing

1

0.25s

3.75s

Flashing

2

0.5s

0.5s

Flashing

3

0.5s

1.5s

Summary of Contents for PACK-LFP-HC48100

Page 1: ...Preface BATTERY PACK LFP HC48100...

Page 2: ...ICEN Be sure to finish reading before installation use So you can use the lithium pack properly After reading it please keep it safe If there is any ambiguity about this specification or if you need t...

Page 3: ...mal capacity 100Ah 3 2 Nominal energy 5 12KWh 3 3 Nominal voltage 51 2V 16Serial cell 3 4 Internal resistance 30m 3 5 Normal charge voltage 57 6 0 3V 3 6 Allowed MAX charge current 50A 3 7 Recommended...

Page 4: ...1 Cycle life DOD100 3000cycles After Normal charge discharge 0 2C current to the end Of discharge voltage Repeat above process until discharge capacity reduce to 80 of initial value Cycle life DOD80 6...

Page 5: ...urrent release Discharge or auto release Discharge over current warning 105 3A Discharge over current protection 110A 3A delay time 5s Discharge over current release Charge or auto release Short circu...

Page 6: ...5 61 LED Sequence SOC ALARM RUN 5 62 Capacity indication Pin Number Pin definition 3 6 GND 2 7 RS485 A 1 8 RS485 B 4 5 NC Pin Number Pin definition 4 CANH 5 CANL 8 GND State Charge Discharge Capacity...

Page 7: ...ity indicator over voltage protection Flashing1 Off Off Off Off Off Temperature over current protection Flashing1 Off Off Off Off Off Discharge Normality Flashing3 Off According to the quantity indica...

Page 8: ...Serial number Application Description Drawing QUANTITY 1 Multiple 1PCS 2 Multiple 1PCS 3 Parallel communication 1PCS 4 Supporting structure 4PCS 5 M8 12mm screw 4PCS 6 M4 8mm screw 16PCS 6 2 Module p...

Page 9: ...6 22 Operating steps Let s take three parallel ones 1 Connect the battery packs through a bracket and use M8 screws 2 Parallel connection...

Page 10: ...3 Communication line parallel connection RS485 4 Open the reset button respectively 5 Turn on the switch separately 6 23 Dialing address selection...

Page 11: ...parallel operation the definition of dial switch is shown in the table below Slave address Add Position of dial switch Instruction 1 2 3 4 1 ON OFF OFF OFF Pack1 2 OFF ON OFF OFF Pack2 3 ON ON OFF OF...

Page 12: ...OFF OFF 2 3 OFF ON OFF OFF 3 4 ON ON OFF OFF 4 5 OFF OFF ON OFF 5 6 ON OFF ON OFF 6 7 OFF ON ON OFF 7 8 ON ON ON OFF 8 9 OFF OFF OFF ON 9 10 ON OFF OFF ON 10 11 OFF ON OFF ON 11 12 ON ON OFF ON 12 13...

Page 13: ...well as all legal regulations No fall down no pile up over 5 layers and keep face up Check the battery immediately after transport the battery l If user finds shell deformation of the battery pack don...

Page 14: ...ower please charge your battery timely 15day Please use the matched or suggested charger for this battery If battery emit peculiar smell heating distortion or appear any abnormity please stop using If...

Reviews: