ANTICIPATION
Anticipation is performed electronically and is independent of the type and load of the components in the
heating and cooling equipment. This thermostat has electronic control based on proportional, integral and
derivative components and maintains temperature to within 1 degree F of the setting. Anticipation is not
adjustable.
OWNER'S MANUAL
Following Installer Setup, check the option boxes (
) in the Owner's Manual according to the configuration of
the thermostat.
QUICK-REFERENCE SETUP GUIDE
This table displays each Installer Setup item with its default setting. The column labeled "CURRENT" can be
used to write down the current settings if any changes are made to the default settings.
Item Number
Description
Default
Current
00
Address
1
01
Communication mode
1
02
System options
0
03
Display options
1
04
Calibration offset
30
05
Cool setpoint limit
51
06
Heat setpoint limit
91
07
Not used
-
08
Not used
-
09
Not used
-
10
Not used
-
11
Cooling minimum on/off time
8
12
Heating minimum on/off time
8
13
Stage 2 differential
2
14
Clock adjust
30
15
Filter reminder
10
16
System runtime (This week)
-
17
System runtime (Last week)
-