QUICK-REFERENCE SETUP GUIDE 
 
This table displays each Installer Setup item with its default setting.  The column labeled "CURRENT" can be 
used to write down the current settings if any changes are made to the default settings. 
 

Item Number 

Description 

Default  

Current 

00 Address 

 

01 Communication 

mode 

 

02 System 

options 

 

03 Display 

options 

 

04 Calibration 

offset 

30 

 

05 

Cool setpoint limit 

51 

 

06 

Heat setpoint limit 

91 

 

07 Not 

used 

 

08 Not 

used 

 

09 Not 

used 

 

10 

Stage 2 differential 

 

11 

Cooling minimum on/off time 

 

12 

Heating minimum on/off time 

 

13 

Auxiliary heat differential 

 

14 Clock 

adjust 

30 

 

15 Filter 

reminder 

10 

 

16 

System runtime (This week) 

 

17 

System runtime (Last week) 

 

 
 
REMOTE SYSTEM WIRING DIAGRAMS 
 
This thermostat has been preprogrammed with energy saving settings recommended under the EPA Energy Star 
program.  When used with remote systems, HAI recommends that the thermostat be configured as "non-
programmable" (See Setup Item 03 - "Display Options"). 

 

 
HAI AUTOMATION SYSTEMS
 
 
The thermostat can be connected to an HAI automation system.  The controller can send commands to the 
thermostat to change mode, cool setting, heat setting, status of fan and hold, and other items. 
 
Run a 3 (or 4) conductor wire from the HAI system to the thermostat location.  All thermostats on an Omni, 
Omni II, OmniPro, or OmniPro II controller are connected to Zone 16 and Output 8.   
 
All thermostats on an OmniLT controller are connected to the GRN (Green), BLK (Black), and YEL (Yellow) 
terminals in the section marked "TSTAT". 
 
Connect the red COMM cable wire with the black COMM cable wire.  Make the connections (as shown in 
Figure 7)
 using the supplied wire splices.   

Summary of Contents for OMNISTAT RC-112

Page 1: ...m current 2 A on any circuit 3 A total Thermostat operating current less than 15 mA The following requirements must be observed for installation in Europe CE 1 This equipment must be installed in acco...

Page 2: ...sting thermostat 3 Disconnect the wires going to each terminal on the thermostat Label each wire with the letter or number at the terminal 4 Remove the existing plate or base from the wall MOUNTING Wh...

Page 3: ...ation See Figures 7 8 Insert the cable into the connector on the thermostat circuit board marked COMM Upon completion of wiring the thermostat push all excess wiring into the hole in the wall Plug the...

Page 4: ...s energized for cooling B Terminal is energized for heating In most applications the reversing valve is energized for cooling and should be connected to the O terminal If the heat pump requires the re...

Page 5: ...5 5 Figure 5...

Page 6: ...2 To configure the display backlight to always be on set the JP2 Select Backlight Mode jumper to the ON position between the middle and bottom pin on the connector See Figure 6 3 To configure the dis...

Page 7: ...at the cooling unit goes off Note As a convenience to the installer the compressor start up protection delay can be canceled To cancel the delay press the Prog key 3 times then press the Fan key 2 tim...

Page 8: ...ured with the following system options WITH NO EEC EEC 0 8 Auto changeover no fan with heat 1 9 Auto changeover fan on with heat 4 12 Manual changeover no fan with heat 5 13 Manual changeover fan on w...

Page 9: ...isplays add 16 to each value The default setting is 1 04 Calibration offset This item is used to raise or lower the current temperature reading by 1 degree Fahrenheit or 1 2 degree Celsius If this ite...

Page 10: ...nimum time set by this item When the cooling system turns off it must remain off for a minimum time set by this item Setting Cycles per hour maximum 5 6 6 5 7 4 8 3 7 10 3 The recommended setting is 8...

Page 11: ...system operation before this reminder is displayed Days Counting down from 10 0 The filter reminder can be disabled by setting this item to 60 16 System runtime This week This item logs the amount of...

Page 12: ...This thermostat has been preprogrammed with energy saving settings recommended under the EPA Energy Star program When used with remote systems HAI recommends that the thermostat be configured as non p...

Page 13: ...TCHES The thermostat can be connected to a remote system or remote switch A signal can be sent from the remote location to change the thermostat temperature settings from the DAY setting to the NIGHT...

Page 14: ...piece of tape Figure 8 Hookup to remote Day Night setback switch OTHER SYSTEMS For connections to personal computers utility management systems and other automation systems refer to connection diagra...

Page 15: ...at keys for test remove jumper SYMPTOM ACTION TO TAKE 1 Check COMM connector and wiring 2 Check thermostat address setting 3 Check communications mode setting Control By Remote System Not Working 4 Ch...

Page 16: ...Reversing valve is connected to wrong terminal move wire from B to O or from O to B The wires connecting the reversing valve may be reversed See Note 2 Page 4 SYMPTOM ACTION TO TAKE No Auxiliary OR Em...

Reviews: