Emergency Dial-Out 

 

 

Emergency dial out consists of two distinct parts: the "digital dialer" and the "voice dialer". 
 

Digital Dialer 

 
The digital dialer (also called a "digital communicator") reports alarm events to a central station monitoring center.  The digital 
dialer sends a digitally coded message to the central station's receiver and computer.  The computer in the central station presents 
your name, address, and other information to a human operator who notifies the appropriate authorities.   
 
Digital communications to a central station are generally superior to voice communications because the central station is always 
staffed with trained professionals and there is virtually no chance for misinterpretation. 
 
The digital communicator will not dial out until the Dial Out Delay has expired.  By default, there is a communicator delay of 30 
seconds.  The delay can be removed or increased up to 45 seconds.  Please consult your installer about the Dial Out Delay.   
 
When enabled, if the alarm is canceled prior to the expiration of the Dial Out Delay, no transmission will take place.  If the alarm 
is canceled after the Dial Out Delay has expired, all alarm trips will be transmitted followed by a Cancel code. 
 
The communicator may be set up to automatically send a test code to the central station on a daily or weekly basis.  This verifies 
proper operation of the entire monitoring system on a periodic basis. 
 
When the digital communicator is used, all voice dial outs will be delayed for five minutes after the expiration of the Dial Out 
Delay to allow time for the central station to call the premises. 
 

If the HAI Two-Way Audio Module is being used, after the transmission of the alarm to the central station, the operator can talk 
and listen to people and sounds at the premises.

 

 
If the digital communicator is unable to successfully communicate with the central station, the console will display a 

Communicator Trouble

 condition.  

 

Voice Dialer 

 
In UL Listed Installations, the Voice Dialer is supplementary to the Digital Dialer described above. 
 
The voice dial-out feature of the OmniLT is a sophisticated system that can notify you at the office, on vacation, on a pocket 
pager, or notify your neighbor, a relative, and in some cases, local authorities. 
 

See

 

What Happens When the Alarm is Activated

also 

Set Up Dial

 

How the OmniLT Voice Dialer Works 
 

 

When a Burglar Alarm, fire alarm, police emergency keys, fire emergency keys, auxiliary emergency keys, gas alarm, water 
alarm, Temperature alarm, or duress alarm is activated, the voice dialer looks at the Dial Order to determine which numbers to 
dial and in what order.  A Dial Order can have up to 8 entries, allowing the dialer to make up to 8 calls.  If you want it to try a 
number twice, it can be entered twice in the dial order. 
 
The dial order numbers can be chosen from Dial Out Numbers 1 - 8. 
 

What the OmniLT Voice Dialer Does 

 

When an alarm is activated, the OmniLT will wait the Dial Out Delay.  If your system is monitored by a central station, it will be 
notified first.  Then the voice dialer will dial out to the numbers as described above.   
 
If the alarm is turned off at the console while a voice dial-out is in progress, the dial-out will be canceled immediately and the 
voice dialer will hang up.  If the number dialed is busy, or if all lines are busy, the dialer will immediately hang up and go to the 
next number in the Dial Order.  The dialer will wait up to 45 seconds after it finishes dialing for a voice to answer the call.  If it 
doesn't hear a voice in that time, it goes on to the next number.  The voice dialer will respond to answering machines. 
 
After it has dialed the last number in the dial order, the OmniLT stops dialing and reconnects the in-house phones. 
 

Summary of Contents for OmniLT SIA CP-01

Page 1: ...Owner s Manual Includes the SIA CP 01 Control Panel Standard Features for False Alarm Reduction Document Number 21R00 1 Rev 2 13 September 2006 ...

Page 2: ...Document Number 21R00 1 Rev 2 13 September 2006 Copyright 2000 2006 HAI All Rights Reserved www homeauto com ...

Page 3: ...tcut Keys 7 Quick Arm 7 What Happens When You Arm the Security System 8 Exit Error 8 Bypassing Zones 9 Auto Bypass 9 Restoring Zones 9 What To Do When You Come Home 10 What Happens When the Alarm is Activated 10 Burglar Alarm Activated 10 Fire Alarm Activated 11 Gas Alarm Activated 11 Emergency Keys 11 Police Emergency 12 Fire Emergency 12 Auxiliary Emergency 12 Duress Code Entered or Duress Alarm...

Page 4: ... RadioRA Units 21 Controlling ALC or X 10 Units 21 Ramp Command ALC 22 Controlling Compose Units 22 Scene Command Compose 22 Timed Commands 23 Status of a Unit 23 Internal Flags 23 Controlling Outputs 24 All On Off 24 All Lights On 24 All Off 24 Leviton Scene Control 25 Scene 25 Scene Commands 25 Scene Set Command 25 Scene On Command 25 Scene Off Command 26 UPB Links 26 Activating and Deactivating...

Page 5: ...ording Your Address 43 Panic Button over the Phone 43 PC Access 43 Emergency Dial Out 44 Digital Dialer 44 Voice Dialer 44 How the OmniLT Voice Dialer Works 44 What the OmniLT Voice Dialer Does 44 What You Hear If Your OmniLT Calls You 45 Entering the Code 45 SETUP 46 Set Up Codes 46 1 Master 46 2 Manager 46 3 User 46 Duress Code 47 Set Up Time 47 Advanced Control Programming ACP 48 1 Add Programs...

Page 6: ...Time Clock Conditions 59 Program Other Conditions 60 Set Up Dial 60 Telephone Access 60 Answer Outside Call 60 Remote Commands 61 Rings Before Answer 61 Dial Type 61 My Phone Number 61 Dial Out Number 1 61 Dial Out Numbers 2 8 62 Dial Order 62 Set Up Arming 62 Entry Delay 62 Exit Delay 63 Exit Time Restart 63 Unvacated Premises 63 Entry Exit Chime 63 Perimeter Chime 63 Enable Quick Arm 63 Enable A...

Page 7: ...RWRITER S LABORATORIES REQUIREMENTS 71 FEDERAL COMMUNICATION COMMISSION NOTICE 72 CANADIAN INDUSTRY CANADA NOTICE 73 APPENDIX A SPECIFICATIONS 74 APPENDIX B CHARACTER CODES 75 APPENDIX C VOICE DESCRIPTIONS 76 ...

Page 8: ......

Page 9: ...vent that there are any questions please call your installer first If you need assistance directly from the manufacturer call us at 504 736 9810 between the hours of 9 00 AM and 5 00 PM Central Time Monday Friday We will be happy to assist you When calling please have the model and serial number of your unit which can be found on the inside of the controller Underwriter s Laboratories UL Listing T...

Page 10: ...Day mode In the Day mode the perimeter zones doors and windows are protected however the interior zones are not armed so that you may move about freely inside In this mode there is an entry delay on entry exit zones 3 NIGHT The NIGHT key is used to arm the security system in the Night mode In the Night mode the doors windows and non sleeping area motion detectors are armed In this mode there is no...

Page 11: ... entered digits and will prompt you to reenter the number 12 KEY The Key is used to enter or confirm a selection It may also be used to display a menu or to offer you additional choices Normal Top Level Display In its normal state the console display will show the day date and time on the top line and the system status on the bottom line If all doors windows sensors etc are closed no zones are byp...

Page 12: ...lowing menu choices are available 1 CONTROL 2 SECURITY 3 BUTTON 4 ALL 5 TEMP 6 STATUS 7 EVENTS 8 MESSAGE 9 SETUP Menu 1 Selects Control functions for controlling lights and appliances Menu 2 Selects Security functions arming disarming bypassing and restoring Menu 3 Allows a Button macro to be activated Menu 4 Selects All Lights On All Units Off commands and Leviton Scene Control commands Menu 5 Al...

Page 13: ...tenance Your OmniLT controller and the consoles are designed to require very little maintenance For smoke detectors motion detectors and other components not manufactured by HAI and follow maintenance procedures outlined by the manufacturer Consoles can be cleaned using a mild detergent and a soft cloth Every three years or if the BATTERY LOW TROUBLE NOW indication comes on and stays on for an ext...

Page 14: ...igit again Practice disarming your system until you are comfortable with this procedure NOTES Panic Tamper and Fire zones are always armed as are the Emergency buttons on the console In the event that the alarm has been activated the menu keys and the arrow keys are locked out You must silence the alarm using the OFF DAY NIGHT or AWAY keys Arming the Security System Now that you know how to disarm...

Page 15: ...ry Exit zones Use this mode when you are leaving for a period of days 5 DAY INST DAY INSTANT Functions same as Day mode however there is no Entry Delay on any of the security zones There will be an instant alarm if any of the zones are violated while in this mode 6 NIGHT DLY NIGHT DELAY Functions same as Night mode however there is an Entry Delay on the Entry Exit zones Use this mode if you are go...

Page 16: ...without causing an alarm The exit time will only be restarted once within a given arming period If Unvacated Premises is enabled if no exit zone is violated during the exit delay i e the premises was not vacated the system will automatically arm to Day mode at the expiration of the exit delay NOTE In Commercial Burglar Alarm Applications for UL Certified Systems a Ring back indication and Bell tes...

Page 17: ...indow or door is open when the system is armed the OmniLT will automatically bypass the zone if it is opened when the system is armed Note that there is an exit delay before the system is armed in any mode The bypass will only take place if the zone is not ready i e open when the exit delay is over and the system is actually armed When a zone is Auto Bypassed it will be automatically restored once...

Page 18: ... show each zone tripped for two seconds The When Alarm macro is activated Any units programmed to come on will do so The Flash For Alarm Unit Number begins to flash on and off The system waits the Outside Siren Delay 0 60 seconds then activates the sounder If enabled the system waits the Dial Out Delay 15 45 seconds and then if programmed the in house phones are seized disconnected and the OmniLT ...

Page 19: ...rm is activated the alarm responds exactly as described under Burglar Alarm Activated except The console display reads GAS ALARM ZONE NAME TRIPPED The sounder will pulse on off on then an extended off period to distinguish it from the burglar or fire alarm The gas alarm takes priority over the burglar alarm however if a fire alarm is already active it will not override the fire alarm NOTE To reset...

Page 20: ...u enter your duress code or a Duress zone is tripped the system performs a silent dial out as follows No alarms lights or console beepers are activated The system does not display the duress alarm The system waits the Dial Out Delay and then begins to dial out Alarm Reset The alarm system will reset itself and turn off the sirens after the system has been in alarm for the configured Alarm Reset ti...

Page 21: ...when a Status Test command is given COMMUNICATOR TRBL NOW or HAD TRBL Indicated if the digital communicator not the voice dialer was unable to make contact with the Central Station after trying both numbers multiple times If this happens there could be a problem with the system central station or the phone line Call your installer for service FUSE TRBL NOW or HAD TRBL Indicated when the solid stat...

Page 22: ...nce the siren 2 To test the security zones you will need a partner to walk around your home and open and close all doors windows etc that are connected to the system while you watch the console Have a partner open each door and window then close it The display should show the zone name as being NOT RDY and then return to SYSTEM OK when closed 3 Have your partner walk in front of all motion detecto...

Page 23: ...al heating and air conditioning systems Direct Relay Control for sprinklers lighting electric heating etc An OmniLT will control 16 UPB switches modules and keypads 2 rooms of HLC Lighting 16 CentraLite loads and relays 16 RadioRA switches and dimmers 16 ALC switch modules 16 X 10 modules one house code 2 PESMs or Voltage Outputs expandable to 10 2 HAI Communicating Thermostats OmniLT also has 8 i...

Page 24: ...Units 9 16 Each room can consist of a maximum of 8 HLC devices configured as follows Up to 7 HAI UPB Wall Switches Dimmers and or Modules for controlling up to 7 lighting loads in a room or area 1 or more Room Controllers set a scene in a room turn the room on and off and dim and brighten the room 1 House Controller for controlling up to 8 rooms of HLC lighting 1 or more House Controllers used as ...

Page 25: ...both rooms it must be set to the last unit number in one of the respective rooms For example set the House Controller to Unit 8 or 16 to control rooms 1 2 This allows you to have up to 2 House Controllers that control rooms 1 2 Within the HLC structure House Controllers can also be configured as a general purpose 8 button keypad controller that is used to trigger 8 different macro programs in the ...

Page 26: ...ontrol the modules individually When a module hears a command from the OmniLT for its house code and unit number it executes the command There are 3 different X 10 formats Standard X 10 Preset Dim Extended X 10 Extended Level and Compose Any module that is X 10 Compatible will work with the OmniLT The modules come in various types House Code OmniLT can control up to 16 lighting and appliance devic...

Page 27: ...ected room on all lighting loads in the room are turned on Press 2 A to set all of the lighting loads in the selected room to their preset levels for Scene A Press 3 B to set all of the lighting loads in the selected room to their preset levels for Scene B Press 4 C to set all of the lighting loads in the selected room to their preset levels for Scene C Press 5 D to set all of the lighting loads i...

Page 28: ...lected lighting load on Press 2 DIM to dim the selected unit 1 9 steps each step is 10 from its current level Press 3 BRT to brighten the selected unit 1 9 steps each step is 10 from its current level Press 4 LVL to set the desired lighting level of the selected unit 0 100 Press 6 LED to turn on or off the LED behind the specified button on a general purpose 8 Button or 6 Button Keypad Specify 1 8...

Page 29: ...e When a RadioRA device transmits a signal i e Switch or Dimmer is turned on or off locally Mater Control button is pressed or Phantom Button is executed OmniLT will automatically update the status of each affected device Controlling ALC or X 10 Units Entry Lights 0 OFF 1 ON 2 DIM 3 BRT Entry Lights 4 LVL 5 RMP 9 TIM STA Press 0 OFF to turn the selected unit off Press 1 ON to turn the selected uni...

Page 30: ...9 TIM STA Press 0 OFF to turn the selected unit off Press 1 ON to turn the selected unit on Press 2 DIM to dim the selected unit 1 9 steps each step is 10 from its current level Press 3 BRT to brighten the selected unit 1 9 steps each step is 10 from its current level Press 4 SCN to set a group of lights to their predefined lighting levels Press 9 TIM to time the selected unit On or Off Timed comm...

Page 31: ...atically update the status of the X 10 unit Internal Flags The easiest way to define a flag it to refer to it as a virtual relay A flag can be in one of three separate states On Off or set to a value between 0 and 255 If a flag has a value of 1 255 it is considered On If a flag has a value of 0 it is considered Off Flags are a powerful programming tool that can be used in several ways to accomplis...

Page 32: ...F CentraLite Program the All On and All Off macro to execute an All On Scene and an All Off Scene on the CentraLite RadioRA Program the All On and All Off macro to execute Phantom Button 16 All On and Phantom button 17 All Off For example WHEN ALL ON PHANTOM BUTTON 16 ON WHEN ALL OFF PHANTOM BUTTON 17 ON This All On Off menu is also used to control Leviton Scenes RadioRA Phantom Buttons UPB Links ...

Page 33: ...X X X 13 X X X X 14 X X X X 15 X X X X UNIT NUMBERS 16 X X X X X Corresponds to the unit numbers in a Scene Scene Commands Scene Commands are used to Set Scenes issue a Scene On command and issue a Scene Off command To issue Scene Commands press the 2 SCENE key You are prompted to enter a Scene number ENTER SCENE 1 16 Enter the Scene number 1 16 followed be the key SCENE 1 0 OFF 1 ON 2 SET Scene S...

Page 34: ... their preset light levels at their preset fade rates For instance in our All On and All Off example when Link 50 On is transmitted by OmniLT each UPB Wall Switch with Link 50 will go to 100 to achieve the All On effect Other Link On activate commands may be transmitted that cause Wall Switch 1 to go to a desired level at a specified fade rate and Wall Switch 2 to go to a different level at a diff...

Page 35: ...sue CentraLite Scenes commands from the top level display or from the main menu press the 4 ALL key on the console keypad and then press the 5 CENLIT key You are prompted to enter a Scene 1 255 ENTER SCENE 1 255 Enter the CentraLite Scene number 1 255 followed be the key CENLIT SCENE 1 0 OFF 1 ON When a CentraLite Scene is turned on all of the devices that are pre programmed for that scene will go...

Page 36: ...s energy savings comfort and convenience by setting the HVAC system s to the proper temperature based on whether you are home asleep away or vacation The temperature can be reported as well as controlled over any telephone A freeze alarm feature will cause a dial out if the temperature falls below a preset level The HAI Communicating Thermostats are digital heating and cooling thermostats that can...

Page 37: ...etting press 2 HEAT 3 COOL or 2 TEMP as appropriate Upstairs HEAT ENTER TEMPERATURE Upstairs COOL ENTER TEMPERATURE Upstairs TEMP ENTER TEMPERATURE Enter the desired temperature then press the key The fan control on a thermostat may be switched between on and auto by selecting 4 FAN from the temperature menu Upstairs FAN 0 AUTO 1 ON Thermostats may be switched between hold mode and the normal run ...

Page 38: ...perature is allowed to rise or fall to an energy saving level When the energy saver is off your thermostat operates normally Your thermostat should be set to the desired comfort temperature Only when the energy saver is on will the temperature be allowed to deviate from your normal thermostat setting There are three temperatures associated with each PESM Temperature this is the air temperature rea...

Page 39: ...ver Modules Upstairs 0 OFF 1 ON 2 HEAT Upstairs 3 COOL 4 TIME STAT For temperature sensors Upstairs 2 LOW 3 HIGH STAT To set a temperature setpoint press 2 HEAT or 3 COOL For Celsius temperatures press the key prior to entering the temperature to make the number negative The Celsius temperature may also be specified in 0 5 degree steps if three numeric digits are entered The third digit adds a 5 t...

Page 40: ...ature The Model 31A00 1 Temperature Sensor is used for sensing temperatures from 0º F 120º F and 31A00 7 Extended Range Temperature Sensor is used for sensing temperatures from 40º F 120º F It features a new high accuracy temperature sensor that doesn t need calibration The temperature can be used to activate programs for controlling temperatures indoors and in attics garages greenhouses basements...

Page 41: ...e humidity from 0 to 100 percent or for sensing the outdoor temperature and or reporting the outdoor relative humidity High and low humidity limits can be set for taking action i e turning on the bathroom vent fan running a c in de humidification mode turning on humidifier in heating mode etc or reporting high or low humidity conditions in homes greenhouses wine cellars coolers humidors etc Contro...

Page 42: ...oom is programmed with 6 consecutive Links starting with Link 1 for example every device in Room 1 is programmed with Links 1 6 Room 2 is programmed with links 7 12 etc Other configuration information When configuring HLC devices using an Omni console or OmniTouch touchscreen each device unit number must first be assigned a name in the OmniLT controller HAI recommends that you first configure your...

Page 43: ...is in Setup Mode Note The HAI 6 Button Room Controller will automatically exit Setup mode after 5 minutes To manually exit Setup mode press and hold the ON and OFF pushbuttons simultaneously for at least 3 seconds To configure the HAI UPB 8 Button House Controller put the device in Setup mode as follows Step Operation 1 Press and hold the 1 and 8 pushbuttons simultaneously for at least 3 seconds 2...

Page 44: ...he second part shows how the OmniLT is currently using the phone line IDLE NOT USING THE PHONE LINE LOCAL LOCAL ACCESS REMOTE REMOTE ACCESS VOICE IN VOICE DIAL OUT MODE EMGACC ACCESS AFTER VOICE DIAL OUT DCM IN DIGITAL COMMUNICATOR MODE BATTERY 230 LIMIT 200 PHONE ONHK IDLE Next the display shows the A D reading for the battery voltage phone line voltage AC power on bell and fuse BAT 225 PHONE 140...

Page 45: ...nd trouble conditions in the system When a new event occurs the oldest one is lost The following Events along with the time and date of their occurrence are recorded in the Event Log when they occur All Security system arming and disarming events Off Day Night Away and Vacation and user name All zones bypassed or restored by the user and user name Any zone automatically bypassed by the system Any ...

Page 46: ...e messages To enter the Message menu from the top level display or from the main menu press the 8 MESSAGE key on the console MESSAGE 1 SHOW 2 LOG 3 CLEAR 4 SAY 5 PHONE 6 SEND Show Message The 1 SHOW key allows you to display the selected text message s on the console s top level display This can be a helpful reminder of special events and occasions TRASH NIGHT ENTER MESSAGE You may enter the messa...

Page 47: ...the selected voice message Send Message Pro Link The 6 SEND key allows you to send any of the text messages through the Pro Link serial port You are first prompted to specify the desired serial port SERIAL PORT 1 2 The built in serial port J5 on the controller is assigned to Serial Port 1 Serial port 2 is a Serial Interface Module connected to the Expansion port on the controller Next select the m...

Page 48: ...ng an ASCII message that is over 15 characters OmniLT only processes the last 15 characters of the message Pro Link determines that a message has been received when One or more characters have been received followed by 100 ms of silence One or more characters followed by a carriage return character are received One or more characters followed by a line feed character are received It is not necessa...

Page 49: ... the OmniLT picks up or hangs up This is normal To access your OmniLT from an in house phone Pick up the receiver of any Touch Tone phone in your house Pause for just a moment about a second then press the key on the phone You will hear the voice read the menu which tells you what commands are available over the telephone NOTE If your system is in High Security Mode you must also enter your code f...

Page 50: ... TEMPERATURE 6 STATUS 7 EVENT 8 PHONE 9 GOOD BYE CANCEL 0 REPEAT This means that you press 1 for Control functions 2 for Security 3 for Button etc Pressing one of the keys on the phone will move you to another menu These menus are the same as the menus on the console Words in brackets are only spoken if that feature is in use You do not have to wait for the OmniLT to finish talking Once you are fa...

Page 51: ...er the Phone On an in house phone only you can activate the Police Emergency keys by picking up the phone and pressing the key 6 times This activates the sounder immediately The first that you press logs you in as usual then the next 5 presses of the key activate the alarm If you are already logged into your system then it takes only 5 presses of the key to activate the emergency alarm To prevent ...

Page 52: ... sounds at the premises If the digital communicator is unable to successfully communicate with the central station the console will display a Communicator Trouble condition Voice Dialer In UL Listed Installations the Voice Dialer is supplementary to the Digital Dialer described above The voice dial out feature of the OmniLT is a sophisticated system that can notify you at the office on vacation on...

Page 53: ...of alarm and the zones tripped for example BURGLAR ALARM ACTIVATED ZONE 1 ENTRY EXIT TRIPPED ZONE 3 DAY INTERIOR TRIPPED Then the OmniLT will read the Main Menu as described in Telephone Control You can press 0 to hear the menu At this point you are in control just as if you had called your system A strategy to follow if you are called by your system is to check the Status 6 on the telephone to se...

Page 54: ...l other user should be assigned a security code with an authority level and times in which the code is valid To set up a code from the Setup menu press the 1 CODES key Use the arrow keys to scroll through the codes CODE 2 0000 9999 0000 DISABLE The existing code number is not shown on the display To change the code enter a four digit number and then press the key Remember the code number It will n...

Page 55: ...ss Code instead of your normal code The system will disarm normally No sirens will sound no lights will flash but the OmniLT will perform a silent dial out and say that this is a silent alarm To stop a silent dial out turn your security system off by pressing OFF then your code DURESS CODE 0000 9999 0000 DISABLE Set Up Time To set up time and date from the Setup menu press the 2 TIME key TIME HHMM...

Page 56: ...lso true at that time The Program menu allows you to add review change and delete automation programs To enter the Program menu from the Setup menu press the 3 PROG key SET UP PROGRAMS 1 ADD 2 SHOW 3 DELETE 1 Add Programs The 1 ADD key is used to add new automation programs to the system When you press the 1 ADD key the Edit Program menu is displayed which allows the various parts of a program to ...

Page 57: ...m The first program is displayed once the down arrow is pressed The top line displays the time or button event that activates the program and any condition that must be true for the program to activate The bottom line shows the command to execute when the program is activated 10 00 PM MTWTFSS AWAY Living Rm Lt ON 6 00 AM 10 10 NIGHT PROGRAM DAY WHEN AWAY ALL OFF The arrow keys are used to scroll t...

Page 58: ...d time Each of these items defaults to its current setting for an existing program that is being edited or to a default value for a new program For each program it is only necessary to specify the time or event and the action to be taken It is not necessary to specify a condition on the program if the action should be taken whenever the specified time or event occurs Edit Programs When Selecting t...

Page 59: ...DAY key You will be prompted to enter the day s that the program will be activated Press 1 7 for Monday Sunday 0 for Once 8 for Weekdays and 9 for Weekends then DAY S M W F 1 7 MON SUN 0 ONCE Press the key and the display will then return to the Edit Program menu EDIT PROGRAM 1 WHEN 2 CMD 3 COND Button and Event Programs Selecting 2 BUTTON from the Edit When menu sets up a program to be activated ...

Page 60: ...elect when the unit turns on this program is executed whenever the unit is turned off or on Press the 2 SWITCH key to select only when the top rocker or bottom rocker is pressed at a UPB RadioRA or ALC Switch locally at the Switch or when a button is pressed on a keypad SWITCH 0 OFF 1 ON 2 11 SW1 SW10 Press 0 to select only when the bottom rocker off is pressed on the Switch Press 1 to select only...

Page 61: ... the event button is activated only when a particular code is used You will be prompted to enter the code ENTER USER CODE 1 16 0 ALL You should enter the user code by entering the code number followed by the key or by using the arrow keys to scroll through a list of code names WHEN C1 AWAY 1 DELAY 2 CODE WHEN C1 A1 AWAY 1 START EXIT 2 END EXIT Zone Event Buttons Pressing the 3 ZONE key allows you ...

Page 62: ...e a program that uses When Link Fade Stop as the trigger When this trigger is used the program will execute when the Link Fade Stop message is received Alarm Event Buttons Pressing the 5 ALARM key allows you to specify a event button activated upon the occurrence of an alarm You are first prompted to select the type of alarm SELECT ALARM TYPE ANY TYPE The arrow keys are used to select from a list ...

Page 63: ...N PHONE DEAD The arrow keys are used to select from a list of event buttons WHEN ENERGY LO WHEN ENERGY MID WHEN ENERGY HI WHEN ENERGY CRIT WHEN PHONE DEAD WHEN PHONE RING WHEN PHONE OFFHK WHEN PHONE ONHOOK WHEN AC PWR OFF WHEN AC PWR ON WHEN BATTERY LOW WHEN BATTERY OK WHEN DCM FAIL WHEN DCM OK WHEN CAMERA 1 6 When a camera input 1 6 is pressed on an OmniTouch with Video Message Event Buttons Pro ...

Page 64: ...ram Command Selecting 2 CMD from the Edit Program menu allows the commanded action for the program to be specified The following menu is displayed 1 CONTROL 2 SECURITY 3 BUTTON 4 ALL 5 TEMP 6 ENERGY 8 MESSAGE After the command is specified the display returns to the Edit Program menu Program Control Commands Press the 1 CONTROL key to command lights and appliances Specify the desired command See C...

Page 65: ...a command message to the device or a Status Request message is issued to the device Unit Toggle Command Using HAI PC Access Software you can create programs to toggle any unit 1 36 from its current state to the opposite state When the program is executed the unit will toggle to Off if the unit is currently in a non off state On On for time Level 1 100 Scene A L Dimmed Steps Dimmed for time Brighte...

Page 66: ...re Commands Select the 5 TEMP key to command thermostats energy saver modules and temperature sensors Specify the desired temperature command See Temperature Program Energy Cost Select the 6 ENERGY key to command the energy cost rate Specify the desired energy cost rate ENERGY COST 0 LO 1 MID 2 HI 3 CRIT Program Message Commands Select the 8 MESSAGE key to show log clear and send text messages or ...

Page 67: ...ether the system is considered in the specified mode during the exit delay INCLUDE EXIT DELAY 0 NO 1 YES Program Zone Conditions Select the 3 ZONE key to specify that the program should only execute if a specified security zone is either Secure or Not Ready The display prompts you for the zone number ZONE ENTER ZONE Enter the zone number followed by the key or use the arrow keys to select the zone...

Page 68: ...ers long The number is shown on the bottom line of the display Press the OFF key to enter a into the number Press the DAY key to specify a pause of 2 seconds shown as a T on the display Press the NIGHT key to enter a into the number Enter a single for no number Telephone Access The Telephone Access item allows you to turn the local in house and remote telephone control feature on and off If set to...

Page 69: ... by pressing the Off key Press the key after you have pressed all of the digits in the phone number For example to enter the number 555 1234 press 555 OFF 1234 Dial Out Number 1 Dial Out Number 1 is one of the 8 numbers that are stored in the system In the event of an alarm these numbers are dialed in the order that is set up in the Dial Out Order for the particular type of alarm Dial out numbers ...

Page 70: ...t Numbers 1 8 You can have the system dial a number twice or more which is suggested if you don t have a direct dial number at work so that your company operator can find you if you aren t at your desk and have you alerted for the next call Up to eight numbers may be entered Enter the Dial Out Order by pressing the keypad digits 1 2 3 4 5 6 7 or 8 for Dial Out Numbers 1 2 3 4 5 6 7 or 8 respective...

Page 71: ...0 NO 1 YES The default setting for Exit Time Restart is Yes Unvacated Premises When Unvacated Premises is set to Yes if the alarm is armed in Away or Vacation mode and no exit zone is violated during the exit delay i e the premises was not vacated the system will automatically arm to Day mode at the expiration of the exit delay To configure Unvacated Premises from the Set Up menu press the 5 ARM k...

Page 72: ...lowing functions Any Control functions Any Temperature Control View the Event Log Access the system from a local phone With High Security Mode Off no code is required to access a local telephone If your system is set up with High Security On the display will request the Master or Manager code whenever you select one of these functions even if the security system is Off Simply enter your Master or ...

Page 73: ...r Console 1 4 Audible Exit Delay is Yes House Code Format The House Code can be configured to use the Standard Preset Dim Command Extended Code Level Command Lightolier s Compose Mode UPB open transmission format Lutron s RadioRA transmission format HAI Lighting HLC or CentraLite transmission format HC 1 FORMAT 5 HAI LIGHTING CHNG To change format for the House Code press the key and then use the ...

Page 74: ... affect the state of the installed devices however if this setup item is set to Yes OmniLT will change the status of all units on that House Code to On even though it doesn t explicitly send an All On command to those units If the House Code All On setup item is set to No OmniLT will not change the status of units on that House Code Time Clocks There are three time clocks in the system are used to...

Page 75: ... standard time at the OmniLT location and Greenwich Mean Time The following values should be used for the standard time zones in North America ZONE NAME 4 ATLANTIC 5 EASTERN 6 CENTRAL 7 MOUNTAIN 8 PACIFIC 9 YUKON 10 ALASKA HAWAII 11 BERING The value specified for longitude may be adjusted to correct for areas such as Nova Scotia where the local time differs from Greenwich Mean Time by a non hourly...

Page 76: ...RT WEEKEND FIRST SUNDAY CHNG DST END MONTH 10 1 12 0 DISABLE DST END WEEKEND LAST SUNDAY CHNG Set the value for DST Start and End Months to 0 if Daylight Savings Time does not apply to your region or to disable this automatic time update feature The DST Start and End Weekend takes place on the specified Sunday 1 7 at 2 00 AM To change the DST Start or End Weekend press the key then use the arrow k...

Page 77: ...ed The names of the event buttons are fixed to a description of the event that activates the button such as WHEN Z1 SEC or WHEN AWAY Set Up Voice The OmniLT can be set up to speak descriptive names such as FRONT DOOR for control units zones buttons codes temperatures and messages These names will be spoken over the telephone along with the item number that is normally spoken To enter the Set Up Vo...

Page 78: ...ONES RESIDENCE 1234 JOHNSON STREET CORNER OF JOHNSON AND THIRD STREET The unit will beep after 8 seconds then play the address back to you If you are not happy with the sound re record by pressing 9 and the Master code If you would like to hear the address again press 8 for Play Address If you accidentally press 9 but have not entered your Master code and do not wish to record a new address simply...

Page 79: ...st be NO 11 The Exit Time Restart feature must be NO Installer NAME __________________________________ NUMBER _______________________________ FIRE ESCAPE PLANNING Your fire protection system is designed to provide warning in the event of a fire It is your responsibility to plan your escape routes in the event of a fire alarm Your family should practice fire drills periodically to ensure that every...

Page 80: ...tice of changes so as to give you an opportunity to maintain uninterrupted service 6 In the event of equipment malfunction all repairs should be made by our company or an authorized agent It is the responsibility of users requiring service to report the need for service to our Company or to one of our authorized agents Service can be obtained at HAI 4330 Michoud Blvd New Orleans LA 70129 7 This eq...

Page 81: ...d connections of the power utility telephone lines and internal metallic water pipe system if present are connected together This precaution may be particularly important in rural areas Caution Users should not attempt to make such connections themselves but should contact the appropriate electric inspection authority or electrician as appropriate Notice The Ringer Equivalence Number REN assigned ...

Page 82: ...Device Fuse Polyfuse 9 A Output Fuse Polyfuse 3 A Battery Fuse Polyfuse 2 5 A Polyfuses are permanent fuses that do not need replacement Nominal Output Voltage 10 13 8 VDC Low Voltage Cut Out approx 9 VDC Typical Current Consumption at Nominal Voltage Controller 105 mA Console backlight off 35 mA backlight on 100 mA CONTROLLER OUTPUTS UL RATINGS MAXIMUM Devices AUX 12 VDC CONSOLE and OUTPUTS 1 and...

Page 83: ...E 0 1 2 3 4 5 6 7 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 8 9 A B C D E F G H I J K L M N O 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 P Q R S T U V W X Y Z _ a b c d e f g 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 h i j k l m n o p q r s t u v w x y z à ß ...

Page 84: ...Y FIVE FIFTY SIX SIXTY SEVEN SEVENTY EIGHT EIGHTY NINE NINETY A M P M WELCOME TO OMNI PAUSE SHORT PAUSE AC POWER ACCESS ADDRESS ALARM ALL 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 APPLIANCE AREA ATTIC AUTO AUXILIARY AWAY BACK BASEMENT BATH BATTERY BED BOY S BRIGHTER BUILDING BURGLAR BUTTON BYPASS CANCEL CENTER CLOSET CODE CONTINUE BEEP...

Page 85: ...OOD BYE GOTO GUEST GUN HAD HALL HEAT HIGH HOLD HOURS HUNDRED INSTANT INTERIOR INVALID IS KITCHEN LEFT LEVEL 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 LIGHT LISTEN LIVING LOW MAIN MASTER MEDICAL MINUS MINUTES MODE MOTION NIGHT NORTH NOT NOW NUMBER NURSERY OFF OFFICE OH ON ONE OR OUTDOOR OUT...

Page 86: ... REMOTE REPEAT RESTORE RIGHT RISE ROOM SAVER SECONDS SECURE SECURITY SETTING SHOP SIDE SILENT SOUTH SPA STAIRS STAR STATUS STEPS STORAGE SUN SYSTEM OK TALK TAMPER TEMPERATURE TEN THEN 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 THERMOSTAT TIME TIMED TO TROUBLE TRIPPED UNIT UP VACATION WATER WEST WINDOW ZONE STOCK UTILITY EQUIPMENT COMPUTER APARTMENT ...

Page 87: ......

Page 88: ...NOTE TO INSTALLER Following installation this manual shall be left for the homeowner s use HAI New Orleans LA U S A ...

Reviews: