Connecting the VSC

ƒ

To connect the Volume-Source Control, 
simply run a Cat-5 cable from the back of 
the VSC to the Zone you’d like to control 
on the Hi-Fi Main Board Assembly.

ƒ

Again, the inputs are labeled with images 
of the VSC for easy installation!

Summary of Contents for OMNI LT

Page 1: ...Installation Simplified by July 2007...

Page 2: ...Cell Phones As a courtesy to all please set your cell phones to silent There will be a break to return phone calls...

Page 3: ...Installation...

Page 4: ...G TELEPHONE LINES 4 WIRE FIRE ZONE EOL COM OUT2 SWITCH 12V WARNING DE ENERGIZE THIS FROM ELECTRIC SHOCK TO PREVENT RISK NO SMOKE ZN 12V 4 WIRE ZN 1K 12V SMK NRM J9 2 WIRE FIRE ZONE Z8 ZONE ZN SMOKE 2...

Page 5: ...PT FOR THE BATTERY ARE POWER LIMITED CLASS II CONNECT CABLE TO CONTROLLER PLUG MODULAR END INTO RJ31X JACK ZONE INPUT ZONE INPUT ZONE INPUT ZONE INPUT ZONE INPUT ZONE INPUT ZONE INPUT ZONE INPUT ZONES...

Page 6: ...THE BATTERY ARE POWER LIMITED CLASS II CONNECT CABLE TO CONTROLLER PLUG MODULAR END INTO RJ31X JACK ZONE INPUT ZONE INPUT ZONE INPUT ZONE INPUT ZONE INPUT ZONE INPUT ZONE INPUT ZONE INPUT ZONES 1 16...

Page 7: ...Phone Line Seizure RJ31X Jack Phone Access Local Remote Central Station Computer Access Bend tab up if necessary to ensure tight fit RED GRAY GREEN GRAY BROWN...

Page 8: ...cklight off 35 mA backlight on 100 mA Outputs 1 8 100 mA Devices Aux 12 VDC Switched 12 VDC Console and Outputs 1 8 1 amp max Horn Int Horn and Ext Horn 1 amp max Operating Temperatures 32 122 degrees...

Page 9: ...ht on 100 mA CONTROLLER OUTPUTS UL RATINGS MAXIMUM Devices Aux 12 VDC Console and Outputs 1 and 2 500 mA Max Bell 1amp Max Outputs outputs 1 and 2 each have a max current draw of 100 mA Battery 12 Vol...

Page 10: ...Console Connection...

Page 11: ...Security System Wiring Door and window security contacts Multiple contacts may be wired in series Z1 Z2 Normally Closed Normally Open Zones Inputs...

Page 12: ...Z1 Normally Closed Zones Inputs Window 1 Window 2 Window 3 Multiple Contacts On a Loop...

Page 13: ...Powered Devices Motion Detectors CO Detectors Glass break Z5 Aux NC Pwr Note Diagram shows a normally closed NC device A normally open device can be used if the EOL is in parallel...

Page 14: ...4 Wire Smoke Detection Note for 4 wire smokes start on zone 5 easier to wire...

Page 15: ...2 Wire Smoke Detection It is recommended NOT to use 2 wire smokes with sounders too much power draw...

Page 16: ...RJ 31X Telco Jack Line seizure to dial out in emergency Ability to use in house phones...

Page 17: ...HAI Consoles Touchscreens...

Page 18: ...Address Each Console Touchscreen Consoles Push and hold 4 up arrow to get into console set up mode Touchscreens Tap and hold HAI logo to get into Touchscreen set up mode...

Page 19: ...Powerline Interface For Lighting and Appliance control Do not plug into surge strip HLC PIM plugs into Serial Port X 10 plugs into X 10 jack...

Page 20: ...Serial Connection...

Page 21: ...Ethernet Omni IIe OmniPro II Lumina and Lumina Pro Controllers Port 4369 128 bit AES Advanced Encryption Standard Use DNS service for Dynamic IP if remote access desired...

Page 22: ...monitored power supply uses 24 V 40 VA transformer 12 V battery Ideal for powering touchscreens Saves on homerun wiring Up to 8 on OmniPro II 10A06 1 Hardwire Expander Mounts on Controller 16 Zones Up...

Page 23: ...Thermostat Installation HVAC wires communication connector Backlight jumper sensor...

Page 24: ...AUXILIARY 12V GND A B CONSOLE INT GND EXT HORN 1 GND 2 3 GND 4 5 GND 6 7 GND 8 OUTPUTS GRN RED BRN GRY PHONE Z9 Z10 Z11 Z12 Z13 Z14 Z15 Z16 Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8 Address Mode Off Prog 3x Fan Locatio...

Page 25: ...ring Detail When used with HAI controller connect black AND red communication wires from thermostat to black wire then black wire to COM at the controller Wire as shown Omni IIe Pro II Lumina OmniLT Y...

Page 26: ...nto set up mode Location 0 is the Thermostat Address Use and v keys to change location value Set thermostats to consecutive addresses 1 2 3 While you re there turn off internal scheduler location 3 5...

Page 27: ...A B CONSOLE INT GND EXT HORN 1 GND 2 3 GND 4 5 GND 6 7 GND 8 OUTPUTS GRN RED BRN GRY PHONE Z9 Z10 Z11 Z12 Z13 Z14 Z15 Z16 Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8 31A00 7 Outdoor Sensor No Direct Sunlight or Direct Ra...

Page 28: ...ick wire for surge lightning protection Connect transformer use a good one with self reset capabilities Omni IIe and Pro II use 24 volt transformers Omni LT uses 16 volt transformer 40 VA transformer...

Page 29: ......

Page 30: ...Input Module To connect the Remote Input Modules simply run a Cat 5 cable from the back of the RIM to the main board assembly The board cover has the images of the remote input modules and is labeled...

Page 31: ...g the Remote Input Module To connect your source equipment to the RIM run a cable from the line out of the device to the standard audio input jack on the front of the RIM HAI sells Zip cables to reduc...

Page 32: ...onnect the Volume Source Control simply run a Cat 5 cable from the back of the VSC to the Zone you d like to control on the Hi Fi Main Board Assembly Again the inputs are labeled with images of the VS...

Page 33: ...r Supply The included power supply is for zones 1 4 and connects to the bottom left input on the main board assembly When expanding an additional power supply is necessary even if you re only adding o...

Page 34: ...Connecting the Speakers Connecting speakers is as easy as running standard speaker wire from the speaker to the main board assembly...

Page 35: ...Want More Power There are two variable outputs Zones 1 and 8 for connection to external power amplifiers Zone 8 Cable Zone 1 Cable from other end of board...

Page 36: ...er To connect the Hi Fi to an HAI Controller run a Cat 5 from the top right hand input on the Hi Fi Main Board Assembly to a serial port on the HAI Controller Just one cable allows you to control Hi F...

Page 37: ...onnections for shorts opens wire whiskers tightness etc Plug in transformer system should power up AC power LED comes on and status light flashes Connect Battery Consoles will beep during power up and...

Page 38: ...Setup...

Page 39: ...c Zone types output types thermostat types Expansion boards and enclosures wireless Digital and voice dialers Longitude latitude time zone etc Programming Where home automation is done coordinating se...

Page 40: ...PCAccess Create programs in PCAccess Review edit delete cut paste copy Search for programs Download to controller...

Page 41: ...Recommendation Just Hit Enter Security Stamp...

Page 42: ...Password Default Password Password...

Page 43: ...Opening screen Open or create a New File...

Page 44: ...Creating a New File...

Page 45: ...Creating a New File Once a controller is selected the file data can not be converted to a different controller...

Page 46: ...All of data on this screen is for company records It is NOT downloaded to the controller Just for your notes Customer Data...

Page 47: ...ays Step 1 Note Use Upper Lower Case Note Always Choose the voice descriptions when text is entered It is an excellent habit Hardware cheat sheet Z Main Control Board EX1 1 Expander 1 Input 1 EE1 1 Ex...

Page 48: ...Setup Names Voice Tab Key...

Page 49: ...Setup Names Voice Units HLC units are labeled on the right...

Page 50: ...1 HLC Configuration HOUSE CONTROLLER MASTER BEDROOM LIVING ROOM CONTROLLER DINING ROOM CONTROLLER LIVING ROOM SWITCHES DINING ROOM SWITCHES...

Page 51: ...7 8 9 Den Room Controller 10 Lights 11 Cove 12 Lamps 13 Bar 14 15 16 House Controller To Use HLC Rooms are set up in groups of 8 units The first unit in a room is reserved for a room controller The l...

Page 52: ...iPro II and Lumina Pro 217 loads 30 rooms Example Omni Controller automatically links 1 Living Room Controller with loads 2 8 and 9 Den Room Controller with loads 10 16 Homeowner can easily adjust sce...

Page 53: ...Setup Names Voice Buttons Note Only use a Button when the customer should have manual control of the routine Use a flag for hidden routines...

Page 54: ...Note Naming users and assigning them individual codes makes reading the even logs easier and more informative Setup Names Voice Codes...

Page 55: ...Setup Names Voice Thermostat...

Page 56: ...phone or out the 2 way voice board Note The text and voice do not have to relate to each other but it does reduce confusion ASCII Messages Sent Received through the RS 232 serial port ProLink M Carria...

Page 57: ...the Correct Port For Serial Connections Code 1 in the software file MUST match Code 1 CURRENTLY in the controller At default both are 1111 After 3 unsuccessful tries you are locked out Pull the trans...

Page 58: ...troller At default both are 1111 After 3 unsuccessful tries you are locked out Pull the transformer and battery to power down the controller The Omni ProII uses a 10Base T connection Change via consol...

Page 59: ...300 Omni II 9600 Pro II 14 4K For Modem Connections Code 1 in the software file MUST match Code 1 CURRENTLY in the controller At default both are 1111 After 3 unsuccessful tries you are locked out Pu...

Page 60: ...Command Set Time Are we currently in Daylight Savings Time Winter No Summer Yes...

Page 61: ...Show Status...

Page 62: ...cellent habit to always confirm hardware connections Omni II Pro II Standard non smoke readings 0 20 High Side Ground Fault 21 35 Trouble 36 80 Low Side Ground Fault 81 110 Trouble 111 136 Closed 137...

Page 63: ...a load Note This can only be reliable information if 2 way devices are used Note When 2 way devices are used the controller will automatically update the status Remember to set the PLC Communication p...

Page 64: ...Command Units Compose Note This screen shot is for a Unit set for Compose Based on how the PLC format is set the Scene command will change to Light Level...

Page 65: ...Command Units Standard Note Notice the Light Level Option Ramp refers to ALC options Off On Dim Brighten Perform the desired command for the time period and then do the opposite...

Page 66: ...Setup Codes Code 1 is the users most powerful code It is always a Master code and will always allow access via PC Access software Never set user 1 to 0 0 0 0...

Page 67: ...Number is spoken during dialed voice notification for alarms Setup Dial...

Page 68: ...Setup Dial T 2 Second Pause...

Page 69: ...Phone is considered a trouble condition Setup Arming Should Say Entry Exit and Perimeter Zone Type Chime All Lights On for Alarm Technically is Force Arm Yes No Turn off when kids have access to the...

Page 70: ...Setup Miscellaneous Settings Which light to flash in alarm Speak alarms out the 2 way voice board A link is in the www homeauto com dealer section User dealer PW haidlr...

Page 71: ...trol Standard X10 PCS Lightolier in Compatibility Mode Extended Leviton ACT A10 Compose Lightolier Compose UPB for non HAI UPB products HLC for HAI Lighting Control Products Include this house code in...

Page 72: ...Setup Miscellaneous Clocks Time Clocks are used to compare against in programs They are not time schedules...

Page 73: ...Setup Miscellaneous DST...

Page 74: ...The 8 Outputs on the Main Control Board Setup Installer Control Set The UPB Network Address and Password...

Page 75: ...Setup Installer Zones This refers to the 17A00 zone expansion cabinet NOT the 10A06 zone expander When Zone Resistors are turned off all zone inputs MUST be Normally Closed...

Page 76: ...a Night Interior but NOT armed in Night Mode 2X or 4X Entry Delay Multiply the standard entry delay time Fire 2 or 4 wire smoke detector Auxiliary ONLY automation no security function Outdoor Temperat...

Page 77: ...Always use Contact ID when available Setup Installer Communicator...

Page 78: ...Setup Installer Partitioning...

Page 79: ...Setup Installer Temperature...

Page 80: ...Setup Installer Miscellaneous Only relates to access to Installer menus on the console Only relates to access to modem call in...

Page 81: ...0 will keep the controller from looking for a phone line Don t forget to return to 8 once the house has a phone line Setup Installer Miscellaneous...

Page 82: ...Setup Installer Miscellaneous Turning off sounder supervision does not turn the supervision current off...

Page 83: ...taller Expansion Module refers to the jumper in the upper left corner Defaults are 1 10A06 Expander 2 ALC Board 3 Serial Board OmniLink HAI Programming Protocol ProLink Custom written ASCII Messages L...

Page 84: ...onsoles You can do all set up and programming from the console using the menus Allows you to get the basics up and running quickly in the field Programs can be added edited or deleted Search capabilit...

Page 85: ...Congratulations You know how to install setup and program HAI Omni Family automation systems...

Page 86: ...Complete training special forms Get HAI Tri Folds to present to your customers Meet requirements to be listed on HAI web site Sign up for HAI lead programs Sign Up for e mail news from HAI Become a F...

Page 87: ...HAI Special Training Offers Promo 11 Omni LT Package Promo 14e Omni IIe Package Promo 16 OmniPro II Package Refer to training flyer for details and limitations...

Page 88: ...Thanks for Attending We hope HAI can be a profitable part of your future...