9. Troubleshooting
Important: If the problems persist, please contact your dealer.
Symptoms
Cause
Problem solving
The engine
does not start
Engine mode lever in the
"STOP" position
Move the lever to the "RUN"
position
Lack of fuel
Refuel
Oil level too low
Top up or change the oil
The power pack is standing on
uneven ground
Place the generator on a level
surface
A spring-loaded
decompression lever closed
the exhalation valve
Open the top panel. Push the
lever down, install the panel.
Start the engine
There is dirty and / or stale fuel
in the fuel tank
Replace fuel with fresh one
The engine is
running OK.
but there is
no voltage
in sockets
The main switch on the control
board is in the "OFF" position
Switch the main circuit breaker
(fuse) to the "ON" position
The RESET button is in the
"OFF" position
Switch the RESET button to the
"ON" position
Błędne podłączenie
przewodów
Check if the connection is
correct or use different cables
Connection of damaged
devices.
Disconnect the device and
connect another.
Loose wiring and / or
connection downstream of
control panel or at the end of
generator
Tighten the wiring nuts
Carbon brush or AVR is worn
or damaged.
Check that they are connected
to both ends of the rotor.
Replace if necessary.
The
generator
works,
but it doesn't
power all
sockets
The generator is overloaded
Reduce the number of
connected devices
A short circuit in one of the
devices
Disconnect damaged or short-
circuiting devices.
The air filter is dirty
Clean the air filter