background image

 

 

 

WaterMax RO Owner’s Manual 

11/13/2012 

11 

WQA–Performance Data Sheet

 

Reverse Osmosis / Activated Carbon Drinking Water Appliance  

 

General Operation Limits 

Model H6000 

Model H6500 

1

 Product output is measured to atmosphere with feed 

water of 77°F, 60 psig (414 kPa) and 360 ppm TDS. 

2

 WQA production is measured against a pressure tank 

@ 5 psi (34 kPa) backpressure, 77°F (25°C), 50 psig 

(345 kPa) and 750 mg/L ± 40 mg/L TDS. 

3

 Efficiency Rating means the percentage of the influent 

water to the system that is available to the user as 

reverse osmosis treated water under operating 

conditions that approximate typical daily usage. 

4

 Recovery Rating means the percentage of the influent 

water to the membrane portion of the system that is 

available to the user as reverse osmosis treated 

water when the system is operating without a storage 

tank or when the storage tank is bypassed. 

NOTE! Actual production rate and TDS reduction will 

vary depending on water temperature, water 

pressure, TDS level, usage, and membrane type. 

5

 Models equipped with TFC membranes incorporate 

activated carbon as pretreatment for chlorine. 

 

Membrane Type 

TFC 

TFC 

Production, gpd (lpd)

1

 

36 (136) 

36 (136) 

Production, WQA

2

 gpd (lpd) 

12 (45) 

14 (53) 

Efficiency Rating

3

  

11.3% 

19.2% 

Recovery Rating

4

 

20.1% 

22.9% 

Pressure, Min-Max, psig (kpa) 

40-100 (276-689) 

30-100 (207-689) 

Temperature, Min-Max, Deg. F (Deg. C) 

40°-113° (4.4°-45°)  40°-113° (4.4°-45°) 

Chlorine Tolerance, ppm

5

 

0.0 

0.0 

Hardness, Max grains 

10 

10 

Iron, Max ppm  

<0.1 

<0.1 

Manganese, Max ppm 

<0.05 

<0.05 

pH, Min / Max  

5.0/9.0 

5.0/9.0 

Hydrogen Sulfide, ppm  

0.0 

0.0 

Turbidity, Max NTU  

1.0 

1.0 

TDS, Max ppm  

2000 

2000 

 

CAUTION! Contaminants in excess of the established  

limits will require pretreatment. 

WARNING! Do not use with water that is microbiologically unsafe or of unknown quality without 

adequate disinfection before and/ or after the appliance. 

 

LIMITED 25 YEAR WARRANTY 

25 years—Dispensing spigot, filter housings and caps, PCF housing, and cap and membrane housing and cap. 
5 years—R.O. storage tank. 
2 years—Permeate pump (H6500 only) and automatic shutoff valve.  
1 year—Membrane. 
Filters—Are not warranted. 

 

REPLACEMENT ELEMENT DIAGRAMS 

Routine maintenance is essential for our products to function at peak performance. Estimated costs are listed with the part numbers. We strongly recommend 

changing the Sediment Pre-filter, Pre-carbon filter, Post-carbon filter and Prolonged contact filter every six months to one year or sooner depending on the 

quality of the feedwater source. Replace the membrane and the drain restrictor when the TDS rejection reaches 75% or less. The practical service life of the 

membrane is three years. Contact your local dealer for service and sanitizing for your Reverse Osmosis drinking water appliance.

H6000

 

 

 

Appliance 

Part Number 

Estimated Cost 

H6000 

Drain Restrictor 

200095-36 

$6.80 

Prolonged Contact Filter 

200190 

$10.32 

R.O. Module 

200298 

$51.80 

Carbon Postfilter 

200195 

$6.44 

Carbon Pre-filter 

200195 

$6.44 

Sediment Pre-filter 

200850 

$3.14 

H6500

 

 

 

Appliance 

Part Number 

Estimated Cost 

H6500 

Prolonged Contact Filter 

200190 

$10.32 

R.O. Module 

200298 

$51.80 

Carbon Postfilter 

200195 

$6.44 

Dual Function Pre-filter 

200851 

$26.80 

 

 

 

Summary of Contents for WaterMax H5000

Page 1: ...CE E O OW WN NE ER R S S M MA AN NU UA AL L A AN ND D I IN NS ST TA AL LL LA AT TI IO ON N G GU UI ID DE E M MO OD DE EL LS S H H5 50 00 00 0 H H5 55 50 00 0 H H6 60 00 00 0 H H6 65 50 00 0 L LC C5 5...

Page 2: ...clusions and Limitations on Warranty This warranty is null and void unless the Hague Appliance was purchased from an independent Hague dealer THERE ARE NO WARRANTIES OTHER THAN THOSE DESCRIBED IN THIS...

Page 3: ...ion for Pentavalent Arsenic Treatment Appliances 12 INSTALLATION AND MAINTENANCE INFORMATION 13 Checklist Before Installation 13 Installation Tool List 14 Installation Diagram 15 Typical Flow Diagram...

Page 4: ...his appliance Note The manufacturer reserves the right to make specification and product changes without prior notice This manual is for installation operation and maintenance of the following RO appl...

Page 5: ...Carbon Flow Restrictor Check Valve Sanitize Air Precharge Shutoff Valve Permeate Pump UV Lamp Water Pressure Water Temperature pH Feed TDS Product TDS Rejection Recovery Notes Important Meeting operat...

Page 6: ...the water temperature Low water pressure and temperature will cause all RO appliances to produce a lower quantity of treated water This appliance is designed with a self regulating flush feature that...

Page 7: ...rough your appliance Caution Connect to the cold water supply only Warning Do not allow your appliance to freeze 5 The rate that water will dispense through your treated water spigot will not be as st...

Page 8: ...Models H5000 H5500 and H6000 If you are using softened water replace your Sediment Pre Filter annually If you are not using softened water the replacement interval will vary Every six months schedule...

Page 9: ...needed Consult your Hague dealer for additional monitoring devices or water check programs Note The installation of your WaterMax RO appliance on a soft water supply will greatly increase the life of...

Page 10: ...FORMANCE OF YOUR WATERMAX RO 1 TYPE OF MEMBRANE Cellulose Tri Acetate CTA Up to 1 200 PPM TDS with pressure of at least 40 PSI Chlorine Tolerant Some bacteria resistance 5 0 to 9 0 pH Excellent produc...

Page 11: ...e Max ppm 0 05 0 05 pH Min Max 5 0 9 0 5 0 9 0 Hydrogen Sulfide ppm 0 0 0 0 Turbidity Max NTU 1 0 1 0 TDS Max ppm 2000 2000 CAUTION Contaminants in excess of the established limits will require pretre...

Page 12: ...ble online at http www epa gov ORD publications ordpubs html Private water supplies and waters that do not have detectable free chlorine residuals should be analyzed to determine the form s of arsenic...

Page 13: ...iphon break See Installation Steps and Start Up Procedures Electricity Check the source of the electrical power The transformer supplied is for a standard 115 volt 60 cycle AC outlet for locations in...

Page 14: ...nch High speed drill bit with 3 8 inch shank for non air gap spigot Air pressure test gauge 1 20 psi 1 inch High speed drill bit with 1 2 inch shank for air gap spigot 7 8 inch chassis punch 1 2 inch...

Page 15: ...H6500 LC50P and LC100P Figure 2 Installation Diagram Notes 1 For maximum flow keep yellow tubing to tank and blue tubing to spigot as short as practical 2 Install feed water line on COLD WATER LINE O...

Page 16: ...WaterMax RO Owner s Manual 11 13 2012 16 Typical Flow Diagram WaterMax H6500 Figure 3 WaterMax H6500 Flow Diagram...

Page 17: ...r s Manual 11 13 2012 17 Booster Pump Retrofit Diagrams WaterMax H5000 For retrofit instructions see form F0873 Figure 4 WaterMax H5000 WaterMax H6000 For retrofit instructions see form F0874 Figure 5...

Page 18: ...ip Collet Cut the tube square It is essential that the outside diameter be free of score marks and that burrs and sharp edges be removed before inserting into fitting Insert the locking clip The locki...

Page 19: ...Drilling a porcelain clad steel or cast iron sink A Mark the sink location for the center of the faucet Be sure the location you select is not over a reinforcing rib Check the location from below B Gr...

Page 20: ...d replace the red locking clip Slip the 1 4 inch black tube onto the small hose barb on the base of the spigot C Slip one end of the loose 3 8 inch black tube over the large hose barb on the base of t...

Page 21: ...supply valve Do not overtighten D Reconnect the riser tube to the other end of the feed water supply valve Do not overtighten Caution A longer riser tube assembly will be required if a gentle loop ca...

Page 22: ...ough one side of drain pipe only C Peel off the white backing from the drain gasket and apply the gasket to the port connection of the drain saddle See Figure 15 Make sure to align the drain saddle to...

Page 23: ...ure they are tight with locking clips in place B Turn on the feed water and check for leaks C Open the valve on top of the storage tank D The appliance is now in operation Step 9 Operation Procedure A...

Page 24: ...ith your RO 5 Inspect the Pre Filter If it is visibly dirty discard it 6 Wash out the filter housing using warm soapy water and rinse thoroughly 7 Sanitize the appliance See Sanitizing the WaterMax RO...

Page 25: ...ckwise See Figure 2 2 Turn off the feed water supply valve 3 Lift the black handle of the dispensing spigot and wait at least five minutes for the pressure to be relieved from the system 4 Remove the...

Page 26: ...the wrapper and use as a sleeve to prevent contamination Wearing clean latex gloves can help prevent hand contact 9 Inspect the O Rings on the pressure vessel end cap and lubricate with glycerin Repla...

Page 27: ...etween 5 and 7 psig 34 and 48 kPa 2 Close the RO spigot 3 Remove the pre filter housing s and discard the spent cartridge s Wash out the housing s with warm water and soap using a bottlebrush and then...

Page 28: ...ollow steps 1 and 2 as outlined above then proceed as follows 1 Remove the Pre Filter housing and discard the spent cartridge Wash out the housing with warm water and soap using a bottlebrush and then...

Page 29: ...r s Manual 11 13 2012 29 Assembly and Parts Feed Water Service Valve Assembly Figure 13 Feed Water Assembly Part Description Quantity 1 200540 Feed Water Service Valve Assembly 1 2 200200 1 4 inch Loc...

Page 30: ...Spigot Lead Free Figure 14 RO Air Gap Spigot Lead Free Part Description Quantity 1 202310 Filter housing wrench 1 2 200350 Air gap spigot assembly 1 3 200360 Spigot adapter 3 8 inch x 7 16 inch J G 1...

Page 31: ...ner s Manual 11 13 2012 31 Assembly and Parts Cont Drain Saddle Assembly Figure 15 Drain Saddle Assembly Part Description Quantity 1 200130JG Drain saddle assembly 2 Piece Plastic 1 2 200199 3 8 inch...

Page 32: ...WaterMax RO Owner s Manual 11 13 2012 32 Assembly and Parts Cont RO Assembly Front View Figure 16 H6500 RO Assembly Front View...

Page 33: ...ane test 1 15 200892 Label prolonged contact filter 1 16 200190 Prolonged contact filter 12 inch H6000 H6500 1 17 200191 Inline nitrate filter Optional 1 18 201165 Pressure vessel O Ring 2 19 200245CJ...

Page 34: ...WaterMax RO Owner s Manual 11 13 2012 34 Assembly and Parts Cont RO Assembly Back View Figure 17 H6500 RO Assembly Back View...

Page 35: ...3 8 inch x 5 foot tubing yellow 1 4 200190 Prolonged contact filter 12 inch 1 5 200191 Inline nitrate filter Optional 1 6 90816 Male elbow 3 8 inch x 1 4 inch Plastic 1 7 200199 Locking clip 3 8 inch...

Page 36: ...WaterMax RO Owner s Manual 11 13 2012 36 Assembly and Parts Cont RO Assembly Top Back View Figure 18 H6500 RO Assembly Top Back View...

Page 37: ...h x 5 foot tubing blue 1 8 200930 3 8 inch x 5 foot tubing yellow 1 9 200245CJG Membrane housing cap black with O Ring 1 10 201165 Pressure vessel O Ring 2 11 202349 Plug in elbow 1 4 inch tube x 1 4...

Page 38: ...Cont Storage Tank Assembly Figure 19 Storage Tank Assembly Part Description Quantity 1 201140 Tank shutoff valve 3 8 inch x 1 4 inch plastic 1 2 200199 3 8 inch Locking clip 1 3 200100 RO storage tank...

Page 39: ...s Part Description Quantity Parts Booster Pump Kit 1 PAB6800 Booster pump 1 2 PAT115 Transformer 24VAC 1 3 PAW260 Pressure switch 1 4 200910 1 4 inch x 5 foot tubing red 1 PAB6800KIT Parts Booster Pum...

Page 40: ...your local Hague dealer No water or not enough water Feed water shut off Turn on your feed water valve Low feed pressure See Filter Specifications chart to verify minimum feed pressure for your model...

Page 41: ...ice cubes are cloudier Change ice cube mold shape make cubes manually if using automatic Let water sit to release dissolved air before freezing RO membrane is bad Membrane fouled hydrolyzed ruptured o...

Page 42: ...icron 20 inch Sediment GAC 5 Micron 20 inch Sediment GAC PCF N A N A Standard Standard N A N A Postfilter GAC GAC GAC GAC GAC GAC Height inches cm 15 25 38 7 15 25 38 7 16 75 42 5 16 75 42 5 28 71 1 2...

Page 43: ...Notes...

Page 44: ...NSF ANSI Standard 58 for materials safety and the reduction of Arsenic 5 Barium Cadmium Chromium 3 6 Copper Fluoride Lead Radium 226 228 Selenium TDS and Turbidity as verified and substantiated by tes...

Reviews: