Model 410
Owner’s Manual
6/24/2014
34
Specifications
410
Max Compensated Hardness–gpg (mg/L)
35 (600)
Minimum pH (standard units)
7
Maximum Ferrous Iron
3
Media type and amounts
Chlorostat (2.0 lb)
Filter Media.(1.5 lb)
Fine Mesh Resin 0.4 cu. ft (11.3 L)
*Salt usage (used per regeneration) / Capacity
1 lb / 5,200 grains (0.5 kg / 365 grams)
*Salt usage (used per regeneration) / Capacity
2 lb / 8,300 grains (0.9 kg / 540 grams)
*Salt usage (used per regeneration) / Capacity
3 lb / 10,400 grains (1.4 kg / 670 grams)
Minimum / Maximum water and ambient temperature–
o
F (
o
C)
40-120 (4- 49)
Mineral tank size–in. (cm)
9 I.D. X 16 (22.9 I.D. X 40.6)
Flow Rate @ 15 psi (1.0 bar) drop – gpm (L/min)
6.0 (22.7)
Flow Rate @ 25 psi (1.7 bar) drop
**
– gpm (L/min)
8.7 (32.9)
Maximum flow rate to drain during regeneration (backwash)–gpm (L/min)
2.4 (9.1)
Water Pressure (min–max psi) (bar)
20–120 (1.4–8.3)
Minimum water flow required–gpm (L/min)
2.4 (9.1)
Controller type
5 Button
Regeneration time–1 lb (0.45 kg) salt setting
12 minutes
Regeneration time–2 lb (0.91 kg) salt setting
15 minutes
Regeneration time–3 lb (1.36 kg) salt setting
18 minutes
Water used/regeneration–1 lb (0.45 kg) salt setting
9.9 gallons (37 liters)
Water used/regeneration–2 lb (0.91 kg) salt setting
13.6 gallons (51 liters)
Water used/regeneration–3 lb (1.36 kg) salt setting
15.6 gallons (59 liters)
Frequency of regeneration
Demand or Timer
Salt Storage (pellet salt)–lb (kg)
30 (13.6)
Height–in. (cm)
21.0 (53.3)
Footprint–in. (cm)
11.5 (29.2) x 18.5 (47)
Electrical Rating
115 VAC, 60 Hz / 220 VAC, 50 Hz
Plumbing Connections (NPT)
3/4-inch or 1-inch. male
Shipping Weight—Approximate–lb (kg)
55 (25)
* Use clean, white pellet, solar, cube-type, block, or brick salt.
**
Flow rates at pressure drop greater than 15 psi (1.0 bar) do not represent the maximum service flow rate used for determining
the softener's rated capacity and efficiency. Continuous operation at flow rates greater than the maximum rated flow @ 15 psi
(1.0 bar) may affect the capacity and efficiency performances. Only the maximum rated service flow @ 15 psi (1.0 bar) shall be
used for the purpose of sizing Point of Entry water treatment devices.
Reduction capabilities for specific contaminants verified by test data.
Name of
Substance
USEPA Max.
Contaminant Level
pH
Flow Rate
Pressure
Barium
2.0 mg/L
7.5 + 0.5
10.0 gpm (38 L/min)
35 + 5 psig (2.4 + 0.3 bar)
Radium 226/228
5 pCi/L
7.5 + 0.5
10.0 gpm (38 L/min)
35 + 5 psig (2.4 + 0.3 bar)