Vertex 5 – Quick Guide
2020-12-02
© 2020, Haglöf Sweden AB.
2020-12-02
CALIBR.DME – CALIBRATING THE ULTRASOUND
1.
Make sure that the instrument has ambient temperature – not colder and not warmer.
2.
Measure the exact distance of 10m/32.8 feet with a measuring tape or similar.
3.
Start the Transponder T3 and place it at the finish of the exact 10m distance.
4.
Go to the zero point for the measured distance and aim the front of the Vertex 5 instrument to the
transponder.
5.
Start the vertex and go to
SETTINGS
and press ON go to
CALIBR. DME
and press ON to confirm.
When the digits 10.00 are shown in the display, the calibration of the Vertex 5 ultrasound is ready.
10,00 m/32.8 feet