RE 15409, Version 08.2022, Bosch Rexroth AB
Function |
CMp 15/64
5 Function
5.1 Product description
Bosch Rexroth S-Link system is an extension to a local hydraulic system control
unit, giving the ability to collect and transmit data for monitoring of the operation.
The S-Link system is delivered with different connectivity options for data
transmission, possibility to add more sensors and has different mounting options.
The main part of the S-Link system is the CCM-module which is the internal
computer, running with Linux operating system and is the communication port to
Häggglunds Spider control system. An option is the MMM-module, providing the
ability to add more sensors to the system for additional monitoring. The data is
sent to the ODiN data base via GPRS-router or via Ethernet for calculation and
evaluation. This documentation is intended to cover all standard options. It may
not cover all details for customized setups.
Please refer to data sheets and the order confirmation for specific technical data,
operating condition and operating limits of your S-Link system setup.
Quality
To assure our quality we maintain a Quality Assurance System, certified to
standard ISO 9001.
5.2 Function
The S-Link system collects sensor data via a serial connection from Hägglunds Dri-
ve System via Spider 2 control system for Condition Monitoring. All existing sensors
connected to the control unit and system internal signals can be used for evaluati-
on. Additional sensors can be added to the S-Link monitoring unit if needed. This re-
quires one or more additional I/O modules for connection of the sensor signals. The
complete sensor signal data package is transferred to the database ODiN for storage
and calculation of system behavior,
see
Fig. 1:
System overview