![hager XEV426 Installation Manual Download Page 11](http://html.mh-extra.com/html/hager/xev426/xev426_installation-manual_578402011.webp)
6LE002957B
b. Settings (cont.)
11
dhcp
0
1
0 Inactive DHCP addressing
1 Active DHCP addressing
Depending on the network configuration
ip_addr
xxx.xxx.xxx.xxx
IP Address
Depending on the network configuration
subnet_mask
xxx.xxx.xxx.xxx
Subnet mask
Depending on the network configuration
gateway
xxx.xxx.xxx.xxx
Gateway
Depending on the network configuration
dns1
xxx.xxx.xxx.xxx
1st DNS address
Depending on the network configuration
dns2
xxx.xxx.xxx.xxx
2nd DNS address
Depending on the network configuration
version
OCPP version of remote server
0
1
OCPP1.5s
OCPP1.6s
login
OCPP server account
Depending on OCPP server configuration
password
Account password
Depending on OCPP server configuration
server
http://...
http address of the OCPP server
Depending on OCPP server configuration
client
Not active
cpref
N characters
Terminal name seen from the OCPP server
Default MAC address
AttachedCable
0
1
Jumper cable
Attached cable
Based on OCPP server configuration
c. Access control
Modify the "b1237 global.cfg" file:
[Whitelist]
Declaration of users (max 250) who
can start and stop their charging
session
[Superuser]
Declaration of super-users (max 10)
who can stop all charging sessions
that are in progress
Id
Open unique number
UID
RFID Card Number in Hexadecimal
hh:mm:ss
Maximum duration of the charging
session (infinite if left blank)
Local access control
In the case of a local access control (Access_control=1), the "b1237 whitelist.txt" file allows you to define a certain number of users who can access the
station to start or stop a charging session, as well as a super-user who can stop any charging session that is in progress.