www.hager.com
6
6T 6070-01a
02.2012
OCOM 113482
Wait! Phone is ringing
Dial the telephone number
“Temperature is 20
°
C.
Output 1 is on…”.
Log in your 4-digit access code
(Factory code is
0000
)
Enter to access parameter setting
“Welcome.
Enter your
access code”
Telephone remote interrogation and control
Hint
:
You can modify a circuit state by pressing the
desired key at ounce before the voice message
ends.
If you type in a wrong access code, the telephone
remote control will signal it.
Three trials are allowed for dialling the code.
If the third one fails, the remote control hangs up
automatically.
Setting the sound volume of voice assistance
Hint
:
Press
0
key to increase or to decrease volume at
any time while connected to the remote control.
Using the device with an answering machine,
modem or fax on the same telephone line
Do as follows:
1. Dial your telephone number from an external
dialling set.
2. Hang up after one ring.
3. Wait 10 seconds.
4. Dial again within the next 2 minutes.
The telephone remote control will open the line
after the first ring.
Technical alarm tripping
When an alarm is activated, the telephone remote
control will open the line and transmit the corres-
ponding voice message to the recorded telephone
number(s) (a max of 3 numbers).
Operation
Recording your own voice messages
You can personalize the main messages
associated with outputs and alarms.
The maximum time of each message is
10s
.
For example:
- Replace the pre-recorded message
“Output 1 is On” by your own message:
"Heating is turned On".
- Replace the pre-recorded message
"Alarm 1" by "Garage door is open".
1. Connect the remote control to the telephone net
work line.
2. Dial your telephone number from an external
dialling set.
3. Follow voice assistance instructions to access
Menu Parameters.
Setting voice assistance sound volume
Press key
0
to increase or decrease volume.
Hint
:
The “
0
” key allows you to adjust the volume at
any time while the telephone remote control is
connected.
Personalizing your access code
Type your 4-digit access code from the
telephone keypad.
The system will ask you to confirm your
new code.
Wait! Phone is ringing
Dial the telephone number
“Temperature is 20
°
C.
Output 1 is on.
Type 1 to modify.
Output 2 is off.
Type 2 to modify”.
Log in your 4-digit access code
(Factory code is
0000
)
Type desired output No. (e.g. “2”)
“Welcome.
Enter your
access code”
“Output 2
is on”.
End of call (Please hang up)
Back to Menu
for other control
Menu Parameters
Programming time delay circuit operation
You can program an operation time for each
circuit (With a minimum of 1s and a maximum
of 59 hrs, 59 min and 59s).
After having set circuit switch-on, the operation
will stop when the time delay set is over.
Setting the number of rings before tripping
You can program the number of rings after
which the telephone remote control will be
activated.
Factory setting is
5 rings
.
Configuring technical alarms
You can activate or deactivate the 2 contact
alarm inputs the alarm temperature and the
mains failure alarm.
Next define alarm-tripping conditions (on
contact opening/closing), and the telephone
numbers to be dialled up (A maximum of 3
numbers).
The alarm temperature requires defining the
tripping level (-29°C to +49°C range) and the
condition (temperature above or below level).
This alarm requires a temperature
measurement probe on temperature input.
For example:
alarm temperature tripping if the measured
temperature is below 15°C.
Mains cutoff is detected on the 230VAC power
supply input.
Alarm mains cutoff is activated when
the cutoff period exceeds 1 minute.
Two cases may occur:
- The 1st correspondent opens the line:
after hearing the alarm message and a
request
for acknowledgement several times, the
correspondent types
*
after the message to
end the call cycle.
- The 1st correspondent does not pick up the
phone, because its line is busy or it does not
end the call cycle.
The telephone remote control calls the next
number set in its memory.
If none of the three correspondents stops
the call cycle, the complete call sequence
(No.1, No. 2, then No. 3) will be repeated
four times and will end automatically.
Mains failure
In case of mains failure, the telephone remote
control dials the recorded telephone numbers
and transmits an alarm voice message
During mains failure, the remote control of the
three outputs is not possible.
The state of circuits is stored before power
shortage and restored at the time of mains
power recovery.
A second message is also transmitted on
power recovery if the time of shortage is
longer than 4 hours (with 100% charged
battery).
Disconnecting the telephone remote control
When receiving a phone call, if the telephone
remote control opens the line before you can
pick up the phone, just type in the sequence of
keys
*
and # to disconnect the device and talk
to your correspondent.
Record your code in a safe place
as it is required to access the
telephone remote control.
Factory code:
0000
The use of a gateway is not