1
Manual local control
Press ON/OFF key of relay output to
be set.
Reset
Press RESET key to reset device
to factory setup using pointed object
(such as ball point end), during
3 seconds mini.
Voice assistance
Position the cursor on the selected
language.
(3 languages are available).
6T 6070-01a
Phone
On/off
OUT 1
Power
English
Reset
On/off
OUT 2
On/off
OUT 3
Espanõl
Português
Phone
On/off
OUT 1
Power
English
Reset
On/off
OUT 2
On/off
OUT 3
Espanõl
Português
TH020B
TH020B
5
2
1
4
3
6
Product description
Power indicator: product power supply.
Telephone jack indicator.
ON/OFF key: local control of output relay
override.
Relay status indicator
- Indicator ON = Relay ON
- Indicator OFF = Relay OFF
Language selection cursor
RESET key: resetting to factory setup
+ Power indicator flickering
Start-up
Reset
Electric connection
Technical specifications
Electrical characteristics
•
Power supply:
230 V AC ± 15% 50/60 Hz
•
Consumption:
< 2 W
•
Analogue Telephone Line:
48V DC
•
Output relays:
250V/0,5A AC1
•
Alarm inputs:
1 input 0-30 V AC/DC, 5mA mini
Switching threshold: 7V, +/- 1V
1 input 0-230V AC, 5mA mini
Switching threshold: 100 V, +/-40%
•
Temperature input:
CTN 10 kOhm
•
Temperature measurement accuracy:
±1°C
•
Battery autonomy:
4 hours
•
Charge time:
72 hours
Size
•
5 modules
Environment
•
Operating T°:
0 °C to +50 °C
•
Storage T°:
-20 °C to +70 °C
•
Class of insulation:
II
•
Protection Index:
IP 20
Connection
•
Capacity:
flexible /rigid conductor: 1x 0,75 mm
2
mini
2x 2,5 mm
2
max
Standards
• EN 60950-1, EN 60669-1, EN 60669-2-1
The telephone remote control is assembled on
DIN rail in the modular electrical box.
*
Lightning protector of telephone line input is
recommended.
**
Recommended temperature probe : EK081,
EK083, EK086
English
Espanõl
Português
-
-
-
On/off
OUT 1
Inputs: IN 1 : 0-30V AC/DC - 5mA min.
IN 2 : 0-230V AC - 5mA min.
Use BT/TBT interface relay
Outputs: OUT 1, 2, 3 : relays 0,5A, AC1
Phone
On/off
OUT 1
Power
English
Reset
On/off
OUT 2
On/off
OUT 3
Espanõl
Português
Phone
On/off
OUT 1
Power
English
Reset
On/off
OUT 2
On/off
OUT 3
Espanõl
Português
TH020B
...
Product presentation
The device allows the user:
• To remotely switch on/off 3 electric circuits (lighting, heating, shutters, spraying, etc.) from any
fixed or GSM portable telephone
• To display room temperature and circuit states in your home at any time
• To receive a call from the device with voice message on any technical alarm triggering (freezer
breakdown, network failure, temperature falling below 10°C, etc.).
A voice device will assist the user in remote control operation.
Only users with confidential access code may operate the telephone remote control device.
Alarm inputs
Nr 1
Nr 2
Temperature probe
&
Alarm inputs
Analogue telephone
line (PSTN) input
230 V AC power supply
&
Network failure detection
Heating
Shifting form programming
mode to frost-free mode
Lighting
Switch on/off
Intrusion simulation…
Rolling shutters
Up/down
Other controls
spraying, pump, …
Voice assistance
User recorded messages
§
Telephone Remote Control and
Transmitter with Voice Assistance
User’s Instructions
Tel.
*
L
N
TH020A / B / C
11 12 13 14 15 16 17 18 19 20
1
OUT 1
IN 1
IN 2
TEL
T
°
C
OUT 2
OUT 3
LN
24V
AC/DC
230 V
AC
234 5 67 8 9 10
Filtre
ADSL
Modem
ADSL
(optionnel)
Tel.
*
Temperature
probe
CTN 10 k Ω
(optional)
**
ADSL
Filter
ADSL
Modem
(Optional)
TH020B
Please provide separate tracking
for power supply cables and
temperature sensor cable.
All configured parameters (such as
access code, user voice messages,
delay periods, etc.) will be cleared
and reset to default values.
Output relays are in idle state,
alarms are deactivated.
The factory access code is