hager I-EA00116 Installation Instructions Download Page 2

4   Programming

 

OUTER

RECEIVER

1

2

3

INNER

RECEIVER

4

 1    DIP SWITCH SETTINGS

 2    HAND HELD CONFIGURATION

1.   Set dip switches on the receiver to the desired activation cycle (dip switch 1 -Toggle or Pulse and dip switch 2 - 0.5s or 10s hold).
2.   Press either Learn w/Delay Button or Learn w/No Delay Button on the receiver depending on the activation requirements

(If delay learn is selected, adjust potentiometer to counterclockwise limit, 0 second delay).  After learn cycle is complete, adjust 

potentiometer to desired delay time (0-30 sec).

3.   Depress transmitter button repeatedly until Blue LED on the receiver illuminates (indicating reception of signal from transmitter).

NOTE:  Repeat Steps 2-3 to program additional transmitters.

4.   To test the system, depress transmitter button (Red LED on Transmitter will illuminate) and observe that the Blue LED illuminates on the 

receiver.  This indicates that the relay has been activated.

 3    PUSH PLATE CONFIGURATION

1.  Before beginning, it is easiest to have already prepared the installation of the push plate.
2.  Connect the wires from the transmitter to the NO and COM contacts of the push plates switch.
3. 

Follow Steps 1-4 (Hand-Held Configuration); depress the pushplate to activate the transmitter

.

4.  Attach the transmitter to the inside of the electrical box and complete the installation.

 4    TYPICAL  VESTIBULE  APPLICATION

 5    REMOVING TRANSMITTER CODE(S)

 

A OUTSIDE TRANSMITTER (PUSH PLATE)

1.  Press Learn w/NO DELAY BUTTON on OUTER Receiver then press Transmitter 1.
2.  Press Learn w/DELAY BUTTON on INNER Receiver then press Transmitter 1.

NOTE:  Set Potentiometer to desired Delay T

ime per Hand Held Configuration Step #2.

B INSIDE TRANSMITTER (PUSH PLATE)

1.  Press Learn w/NO DELAY BUTTON on INNER Receiver then press Transmitter 2.
2.  Press Learn w/DELAY BUTTON on OUTER Receiver then press Transmitter 2.

NOTE:  Set Potentiometer to desired Delay T

ime per Hand Held Configuration Step #2.

C VESTIBULE TRANSMITTERS (Dual Switch Push plate or Two Separate Push plates)

1.  Press Learn w/NO DELAY BUTTON on INNER Receiver then press Transmitter 3.

2.  Press Learn w/NO DELAY BUTTON on OUTER Receiver then press Transmitter 4.

SINGLE TRANSMITTER CODE

1.  Press both DELAY and NO DELAY BUTT

ONS simultaneously until Red LED flashes once (approximately 1 second).

2.  Press transmitter button twice within 10 seconds and the transmitter code will be deleted.

ALL  TRANSMITTER CODES

1.  Press and hold both DELAY and NO DELAY BUTTONS simultaneously until Blue LED illuminates then release (approximately 10 seconds).

# 1

DESCRIPTION

FUNCTION

OFF Pulse Relay

Press the transmitter once and the relay will be active momentarily.

ON

Toggle Relay

Press the transmitter once and the relay output is active indefinitely

,

press it again and the relay will de-energize indefinitel

y.

# 2

DESCRIPTION

FUNCTION (Pulse Mode Only)

OFF 0.5 sec Hold Time Relay will remain active 0.5 second after the loss of activation.
ON

10 sec Hold Time

Relay will remain active 10 seconds after the loss of activation.

 1   2

 

ON

0.5s l 10s

PUL   

TOG

 1   2

 

ON

0.5s l 10s

PUL   

TOG

In Toggle Setting (1-ON), the Hold Time

 is inactive.  Either setting for #2 dip

 switch will have the same result.

 1   2

 

ON

0.5s l 10s

PUL   

TOG

 1   2

 

ON

0.5s l 10s

PUL   

TO

G

0.5 second

Pulse Setting

10 second

Pulse Setting

07/24/2013        Hager Companies   •   139 Victor Street   •   St. Louis, MO  63104   •   800 325 5559   •   www.hagerco.com          Page 2 of 4

433 MHz Transmitters & Reciever

Installation Instructions

Digital Transmitters and Receiver with Sequencing Function

I-EA00116

433 MHz Transmitters & Reciever

Installation Instructions

Digital Transmitters and Receiver with Sequencing Function

I-EA00116