2  Project implementation

Log in to the app as administrator (Figure 6)

Following project handover, the administrator automatically receives an e-mail in the coviva app 

from his or her electrician indicating that 

Connected Home

 can now be used and containing the 

access data (e-mail address). The administrator can now log in to the coviva app.
The (mobile) end device is online.

 

„

Open the coviva app  .
The coviva ID for connecting to the smartbox is displayed. If this is not the case, use 

 and 

the (mobile) end device's camera to scan in the coviva ID shown on the rear side under the 

cover or enter it via the keypad.

 

„

Select 

Login

 to change over to the login page.

  The administrator must have a 

myHager

 account. If an account has not yet been created, 

following handover, the user will be forwarded to the registration page the first time he or she 

attempts to log (see setting up 

myConfigure myHager account account

).

Enter 

User name 

 and the 

Password 

for 

myHager

 account and log in with 

Add user

If the 

General Term of Use (GToU) 

for the coviva app have not yet been accepted in the 

my-

Hager

 account, the corresponding web page must be accessed at this point.

 

„

To do this, press the 

myHager GTC

 buton.

 

„

Accept the GToU via the checkbox and complete the operation via 

Save

.

 

„

Afterwards, log in again to the app.

i

my devices

my groups

my covigrams

Off

Off

Off

Wall light living ro...

Living

Scene TV

Ceiling light living

Standard lamp_85...

Q W E R T Y U I O

A S D F G H

Z X C V B N M

J K L

P

space

return

.?123

my.customer@email.com

Login

Login

Back

Welcome to coviva !

The unique ID on the rear of your 

coviva controller connects you directly 

to your coviva 

0024C6F21834

Test without login

Login

Welcome to coviva!

Your electrician has set up your coviva Box 
for you.
You can now enjoy your connected home. 

Download the coviva app:

Download the app to your device here.  

Your myHager access data:

my.client@email.com

Kind regards,
Your Hager Vertriebsgesellschaft team

Input (265)

MyHager GToU

To use coviva application, General 

Terms of Use shall be validated for 

you MyHager account. Please 

click“MyHager GToU” button to be 

redirected for the validation.

General Term of Use

Terms of use

Please confirm the terms and conditions of use 
for your coviva Smartbox.

Personal data

coviva terms and conditions of use 

*

I accept the 

coviva terms and 

conditions of use 

of dated 31/01/2017.

*

 Mandatory fields

Hager Ldt.

 Save

Hager Ltd.

Publication details    Data privacy    Cookie policy

Terms of use

Please confirm the terms and conditions of use 
for your coviva Smartbox.

Thank you

We have saved your consent in your myHager 
account.
Please now re-open the coviva app on your 
smartphone or tablet, navigate back to the login 
form and enter your myHager password again. 
You should be able to activate the app 
immediately.

Hager Ltd.

Publication details   Data privacy   Cookie policy

Hager Ltd.

Figure 6: E-mail and administrator login

hager.com

coviva Smartbox

Summary of Contents for coviva Smartbox TKP100A

Page 1: ...Page 1 34 05 2019 Operation and configuration instructions hager com coviva Smartbox coviva Smartbox TKP100A WLAN stick TKH180 Power supply replacement requirement TKC110...

Page 2: ...11 Add device to the project 11 Add Connected device Figure 10 12 Combine devices into groups Figure 11 12 Edit remove group Figure 12 13 Create covigram 15 Example 1 Temperature warning Figure 13 16...

Page 3: ...AN 4 Connection power supply 5 QR code with coviva ID 6 Operation LED POWER 7 WLAN Display only active with optional WLAN stick see Accessories 8 Status display ONLINE 9 Acknowledge button OK 10 Butto...

Page 4: ...bile end devices or stationary computers by means of a mobile app or browser based web app In this way location independent access to the building control via the home network and via the Internet can...

Page 5: ...e or via optional WLAN stick see Accessories The device is only suitable for indoor areas Product characteristics secure system administration via user profiles with different rights control of KNX ra...

Page 6: ...ing the system not required Family members fellow occupants Table 1 User profiles Detailed information on the access rights per user profile can be found in an overview table in the appendix Configure...

Page 7: ...install app The app requires at least version IOS 7 1 or Android 4 1 or higher on the mobile end device Call up coviva web app As an alternative to the mobile app it is also possible to access the sm...

Page 8: ...l light living ro Living Scene TV Ceiling light living Standard lamp_85 Q W E R T Y U I O A S D F G H Z X C V B N M J K L P space return 123 my customer email com Login Login Back Welcome to coviva Th...

Page 9: ...coviva Devices Groups Covigrams Favorites Logout Peter Principle Me Others Users Settings Meier Installer coviva ID 0024C6F21834 Date Time 09 11 16 00 00 coviva Language English coviva Vers 2 6 7 cc24...

Page 10: ...formed on the smartbox in order to restore the project to its status prior to handover Max Save User Surname E mail Phone User name Rights Change password Classic Contact Profile Max email com Max ema...

Page 11: ...te restore the connection with Retry If the update is to be carried out at a later time first decline the update via Later Each time the app is subsequently opened the update will be offered again i m...

Page 12: ...9 0 Let s go Add a device space 123 Adding Netatmo weather station Enter the user name and password of your Netatmo account Peter email com return my devices Wall light living room Ceiling light livin...

Page 13: ...en Mirror hall Ceiling light hall Wall light bathroom Blind kitchen Blind living room i Off my devices Off Off my groups Wall light living room Eat in kitchen Ceiling light living Standard lamp sofa L...

Page 14: ...Scene TV Eat in kitchen Ceiling light living Standard lamp s Devices Detail Ceiling light living Wall light living room Standart lamp_851 Q W E R T Y U I O A S D F G H Z X C V B N M J K L P Detail Sav...

Page 15: ...to trigger actions only on certain days of the week an additional and linked time trigger must be added Play When selecting the manual trigger one several action s can be started exclusively by an op...

Page 16: ...ton of the trigger type is highlighted in red All devices of the project are listed with symbolic buttons and their name The display can be swiped to the left and right Select the device by pressing t...

Page 17: ...s or If and And only and Then Covigrams Save Temperature warning Heati k and or And only and Then If Figure 13 Covigram for example 1 Trigger Define action Press the button under Then The page for de...

Page 18: ...ng page Covigramm opens The title line under is activated Give the covigram a name via the keypad and terminate the entry with the Return button Define trigger In the file view of the covigram via und...

Page 19: ...ave Trigger Choose a device Choose a trigger Time Event Play Set trigger Switch on Input Switch off Input Input Sidewalk Housewa Bedroom Kitche Detail Save Outdoor light eve Sa 19 00 eve Mo 17 03 or I...

Page 20: ...Then is added Define all other blinds in the house in the same way as action Complete the covigram with Save The covigram is displayed in the main menu Trigger Save Choose a trigger Event Set trigger...

Page 21: ...button The page for defining a further trigger opens Proceed as described above Add further actions under Then via the button The page for defining a further action opens Proceed as described above R...

Page 22: ...Q W E R T Y U I O A S D F G H Z X C V B N M J K L P Save return save 123 Detail Temperature message Heati s Heati k or Then If Back i my groups my covigrams Off Off Wall light living room Scene Tv Ea...

Page 23: ...mp sofa_85105100 Weather station Outdoor module Wind gauge Alarm system Rain gauge Favorites Save Ceiling light living_TRE202_K1 Wall light living room_TRE202_K1 Standard lamp sofa_85105100 Alarm syst...

Page 24: ...ils Save Back Remove Device Remove from favorites Standard lamp_85105100 my covigrams my favorites Off Eat in kitchen Temperature warning Outdoor light All OFF Wall light living_TR my covigrams my fav...

Page 25: ...lands Espanol Polski Portugues T rkce coviva Version 2 6 7 cc24680 KNX Version 1 1 13 Alarm Version 1 0 6 User see also Add user Figure 7 My account Name First name Last name Peter Administrator Conta...

Page 26: ...stalled App Version 3 3 0 Copyright Hager Group 2015 All rights reserved Amazon Alexa Connect Google Assistent Connect IP adress 192 168 178 23 Voice Control Network i coviva Devices Groups Covigrams...

Page 27: ...bile app or scrolling web app up or down i 100 50 my devices my covigrams Off 23 5 C 23 5 C 22 6 C 4 8 C Dimmer Bedroom Blind living room Socket living room Heating Bedroom Heating Children Netatmo Ba...

Page 28: ...ormation regardless of the user profile The operating concept is intuitive and corresponds to the routines of other app operations Below is an overview of the basic operating modes and applications in...

Page 29: ...measuring unit Physical sensors Measured values of a weather station such as Indoor temperature Relative humidity indoors CO2 content of the indoor air Volume in the room Air pressure indoors With ot...

Page 30: ...otifications or connected devices of other manufacturers Carry out a networkreset A manual network reset can be performed on the smartbox Reset Mode Trigger Consequences of the reset Network reset Los...

Page 31: ...ws convenient remote access by the electrician in order to work in the project without having to be onsite with the customer With remote access it is possible for example to check the state of the ins...

Page 32: ...he Installation access The electrician can once more no longer edit the project remotely i coviva Devices Groups Covigrams Favorites Logout Off Off Off i i i i i i space return 123 My account Principl...

Page 33: ...eate groups Edit remove groups Create covigrams Edit remove covigrams Add to favourites Remove from favourites Install update before project handover Install update after project handover Hand over pr...

Page 34: ...4 53 UE from June 2017 The CE declaration of conformity can be consulted on the site hagergroup com Correct Disposal of This product Waste Electrical Electronic Equipment Applicable in the European Un...

Reviews: