8300 Low Energy Auto-Operator
Quick Start Guide
I-EA00259
Rev 1, Rev Date: 1/16/2019
Always visit www.hagerco.com for the latest Installation Instructions
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995
Reveal
Hinge Hung ‘X’ Dim.
Center Pivot ‘X’ Dim.
0"
13"
16"
1"
14"
17"
2"
15"
18"
3"
16"
19"
4"
17"
20"
5"
18"
21"
6"
19"
7"
20"
8"
21"
DEEPER REVEAL REQUIRES ARM EXTENSION
STEP 2:
WIRING
a) Ensure the main voltage (120VAC) coming into header is off.
b) Connect the 120VAC power source to the operator inside the header.
c) Connect the ground wire to the back-plate.
Push arm length
STEP 3:
POWER-ON & INITIAL SETUP
NOTE: Jumpers are pre-installed at the factory between
inputs 8, 12, 13 and 14. Do NOT remove these jumpers
until the setup is complete. If these inputs are not
required for the application, leave the jumpers installed.
a) Ensure the doorway is clear – apply 120VAC power to the
operator.
b) Observe the control LED’s: The green LED’s should be
illuminated for terminal number 12, 13, and 14. If they are not,
check related pre-installed jumper wires or check to make sure
the connected circuits are N.C. Correct before proceeding
c) Press & hold the setup button until the red LED begins to
flash at the control board. Release the button
d) The door should slowly begin to open after a few seconds
and will then recycle partially and fully during set up and door
first opening cycle, set your foot to the location you want your
door to stop at (electronic soft then let go and let the door
learning cycle stop). Proceed until red LED stops flashing. Once
complete, the door will begin to close and the red LED will
expire. Setup is now complete.
e) Normal activation will be allowed approximately 2 seconds
after the door closes fully.
STEP 4:
TUNE-IN
a) Activate the door by applying a jumper to terminals 8 & 10. The door should open and close smoothly.
b) Adjust the open speed, closing speed, and hold open time delay accordingly.
c) A re-learn is not required following any speed or time adjustment. It is only required if the stroke changes.
d) Once complete, check speed, force, and time delay for compliance to the current ANSI A156.10 performance standards.
e) Proceed with remaining wiring for the application such as sensors, push plates, presence sensors, etc. Refer to Users
Guide for further instruction.