hager 8300 Series Quick Start Manual Download Page 2

8300 Low Energy Auto-Operator 

Quick Start Guide

I-EA00259

Rev 1, Rev Date: 1/16/2019

Always visit www.hagerco.com for the latest Installation Instructions

HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995

Reveal

Hinge Hung ‘X’ Dim.

Center Pivot ‘X’ Dim.

0"

13"

16"

1"

14"

17"

2"

15"

18"

3"

16"

19"

4"

17"

20"

5"

18"

21"

6"

19"

7"

20"

8"

21"

DEEPER REVEAL REQUIRES ARM EXTENSION

STEP 2: 

WIRING

a) Ensure the main voltage (120VAC) coming into header is off.

b) Connect the 120VAC power source to the operator inside the header.

c) Connect the ground wire to the back-plate.

Push arm length

STEP 3: 

POWER-ON & INITIAL SETUP

NOTE: Jumpers are pre-installed at the factory between 

inputs 8, 12, 13 and 14. Do NOT remove these jumpers 

until the setup is complete. If these inputs are not 

required for the application, leave the jumpers installed.

a) Ensure the doorway is clear – apply 120VAC power to the 

operator.

b) Observe the control LED’s: The green LED’s should be 

illuminated for terminal number 12, 13, and 14. If they are not, 

check related pre-installed jumper wires or check to make sure 

the connected circuits are N.C. Correct before proceeding

c) Press & hold the setup button until the red LED begins to 

flash at the control board. Release the button

d) The door should slowly begin to open after a few seconds 

and will then recycle partially and fully during set up and door 

first opening cycle, set your foot to the location you want your 

door to stop at (electronic soft then let go and let the door 

learning cycle stop). Proceed until red LED stops flashing. Once 

complete, the door will begin to close and the red LED will 

expire. Setup is now complete.

e) Normal activation will be allowed approximately 2 seconds 

after the door closes fully.

STEP 4: 

TUNE-IN

 

a) Activate the door by applying a jumper to terminals 8 & 10. The door should open and close smoothly.

b) Adjust the open speed, closing speed, and hold open time delay accordingly.

c) A re-learn is not required following any speed or time adjustment. It is only required if the stroke changes.

d) Once complete, check speed, force, and time delay for compliance to the current ANSI A156.10 performance standards.

e) Proceed with remaining wiring for the application such as sensors, push plates, presence sensors, etc. Refer to Users 

Guide for further instruction.

SETUP BUTTON

DL2
DL3
DL4
DL5
DL6
DL7
DL8
DL9

Red Flashing 

LED (DL2)

Page 2 of 2