2
Information for electricians
Installation and electrical connection
DANGER!
Touching live parts can result in an electric shock.
An electric shock can lead to death.
Disconnect the connecting cables before working on the device and
cover all live parts in the area!
ç
Preparing the device for installation
(for example “16AX 2gang 1way switch”)
1
Cover
Notches
Carefully loosen the cover on the notches with a flat-blade screwdriver (
1
).
Remove the cover.
Connecting the device
L
N
C
L1
N
N
L
L
2A
1way switch
General
circuit diagram
1gang 1way
switch
2gang 1way
switch
1way